期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
1
作者 何乐 孙贺江 《Journal of Central South University》 SCIE EI CAS 2009年第S1期111-117,共7页
An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps wa... An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps was discussed. By comparing various methods of energy consumption analysis,a modified Bin method based on the weather data in Tianjin was adopted. The heat consumption of the buildings under intermittent heating mode was calculated and compared with continuous heating mode,the result shows that intermittent heating can reduce energy consumption for 1 941 759 kW·h,save standard coal for 341 t,and reduce pump power consumption for 72 679 kW·h annually. Intermittent operation by means of varying the pump frequency not only leads to savings in fuel consumption and reduction in pollutant emissions,but also reduces operating costs significantly and it is an ideal energy-saving method. By analyzing the results,the recommendations of heating operation regulation and the transformation of pipe network were proposed separately to different kinds of buildings in colleges,such as laboratory building,teaching building. 展开更多
关键词 BIN method INTERMITTENT HEATING METEOROLOGICAL parameters ENERGY-SAVING of buildings
在线阅读 下载PDF
Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air 被引量:5
2
作者 丁研 田喆 朱能 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期735-746,共12页
The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the ded... The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system(DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system(RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels(CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system. 展开更多
关键词 air-supply mode hybrid system radiant cooling humidity stratification
在线阅读 下载PDF
Energy efficiency performance of multi-energy district heating and hot water supply system 被引量:2
3
作者 金楠 赵靖 朱能 《Journal of Central South University》 SCIE EI CAS 2012年第5期1377-1382,共6页
A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the ne... A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324. 展开更多
关键词 geothermal energy solar thermal energy district heating hot water supply
在线阅读 下载PDF
Optimal scenario balance of reduction in costs and greenhouse gas emissions for municipal solid waste management 被引量:1
4
作者 邓娜 张强 +4 位作者 陈广武 齐长青 崔文谦 张于峰 马洪亭 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期887-894,共8页
To reduce carbon intensity, an improved management method balancing the reduction in costs and greenhouse gas(GHG)emissions is required for Tianjin's waste management system. Firstly, six objective functions, name... To reduce carbon intensity, an improved management method balancing the reduction in costs and greenhouse gas(GHG)emissions is required for Tianjin's waste management system. Firstly, six objective functions, namely, cost minimization, GHG minimization, eco-efficiency minimization, cost maximization, GHG maximization and eco-efficiency maximization, are built and subjected to the same constraints with each objective function corresponding to one scenario. Secondly, GHG emissions and costs are derived from the waste flow of each scenario. Thirdly, the range of GHG emissions and costs of other potential scenarios are obtained and plotted through adjusting waste flow with infinitely possible step sizes according to the correlation among the above six scenarios. And the optimal scenario is determined based on this range. The results suggest the following conclusions. 1) The scenarios located on the border between scenario cost minimization and GHG minimization create an optimum curve, and scenario GHG minimization has the smallest eco-efficiency on the curve; 2) Simple pursuit of eco-efficiency minimization using fractional programming may be unreasonable; 3) Balancing GHG emissions from incineration and landfills benefits Tianjin's waste management system as it reduces GHG emissions and costs. 展开更多
关键词 fractional programming greenhouse gas(GHG) emissions eco-efficiency waste management
在线阅读 下载PDF
Exploring heating performance of gas engine heat pump with heat recovery 被引量:3
5
作者 董付江 刘凤国 +2 位作者 李先庭 尤学一 赵冬芳 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期1931-1936,共6页
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1... In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature. 展开更多
关键词 gas engine heat pump coefficient of performance primary energy ratio heating mode heat recovery
在线阅读 下载PDF
Optimal operation of water distribution networks under local pipe failures 被引量:3
6
作者 田一梅 G.Y.FU +1 位作者 迟海燕 刘烨 《Journal of Central South University of Technology》 EI 2007年第3期436-441,共6页
The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic mod... The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic model for a network under a local pipe failure was established by the statistical regression. After the operation objectives under a local pipe failure were determined, the optimal operation model was developed and solved by the genetic algorithm. The program was developed and examined by a city distribution network. The optimal operation alternative shows that the electricity cost is saved approximately 11%, the income of the water corporation is increased approximately 5%, and the pressure in the water distribution network is distributed evenly to ensure the network safe operation. Therefore, the proposed method for optimal operation under local pipe failure is feasible and cost-effective. 展开更多
关键词 water distribution network local pipe failure macroscopic model optimal operation
在线阅读 下载PDF
Experimental study on co-pyrolysis characteristics of typical medical waste compositions 被引量:6
7
作者 邓娜 崔文谦 +3 位作者 王维维 张强 张于峰 马洪亭 《Journal of Central South University》 SCIE EI CAS 2014年第12期4613-4622,共10页
Thermal decomposition of 21 kinds of binary mixtures between typical medical compositions was investigated under nitrogen conditions by dynamic thermogravimetric analysis(TGA) at 25–800 °C. The weighed sum metho... Thermal decomposition of 21 kinds of binary mixtures between typical medical compositions was investigated under nitrogen conditions by dynamic thermogravimetric analysis(TGA) at 25–800 °C. The weighed sum method(WSM) coupled with thermal analysis was applied to study the interaction between components. Then, co-pyrolysis kinetic model of the binary mixtures(tube for transfusion(TFT) and gauze) was established to verify the reliability of conclusions. The results show the follows. 1) Strong or weak interactions are shown between binary mixtures containing polyvinyl chloride(PVC), the main ingredient of TFT. The addition of other medical waste could enhance first stage decomposition of TFT. While, the secondary stage pyrolysis may be suppressed or enhanced or not affected by the addition. 2) There exists no interaction between catheter and other component, the DTG peak temperature representing Ca CO3 decomposition in catheter fraction is obviously lower than that of pure catheter; while,the shape of DTG peak keeps unchanged. 3) No evident reaction occurs between the other mix-samples, it is considered that their co-pyrolysis characteristics are linear superposition of mono-component pyrolysis characteristics. 展开更多
关键词 co-pyrolysis medical waste tube for transfusion(TFT) catheter interaction
在线阅读 下载PDF
Effect of thermal storage performance of concrete radiant cooling room on indoor temperature 被引量:1
8
作者 辛亚娟 王志强 田喆 《Journal of Central South University》 SCIE EI CAS 2012年第3期709-714,共6页
A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by T... A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by TRNSYS. The comparative analysis of the characteristics of attenuation and delay proves that the operation of radiant cooling system increases the degree of temperature attenuation of the room and reduces the inner surface temperature of the wall significantly, but has little effect on the attenuation coefficient and delay time of wall heat transfer. The simulation results also show that the inner surface temperature of the walls in the radiant cooling room is much lower than that in non-cooling room in the day with the maximum cooling load, which reduces the indoor operation temperature largely, and improves the thermal comfort. Finally, according to the analysis of indoor temperature of the rooms with different operation schedules of cooling system, it can be derived that the indoor mean temperature changes with the working time of radiant cooling system, and the operation schedule can be adjusted in practice according to the actual indoor temperature to achieve the integration of energy efficiency and thermal comfort. 展开更多
关键词 concrete radiant cooling thermal storage performance cooling load operating schedule TRNSYS
在线阅读 下载PDF
Intelligent prediction on performance of high-temperature heat pump systems using different refrigerants 被引量:1
9
作者 YU Xiao-hui ZHANG Yu-feng +4 位作者 ZHANG Yan HE Zhong-lu DONG Sheng-ming MA Xue-lian YAO Sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第11期2754-2765,共12页
Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2... Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance. 展开更多
关键词 high-temperature heat pump experimental performance support vector machine back propagation neural network performance prediction
在线阅读 下载PDF
Experimental investigation and energy consumption analysis for subway side-platform in north cities
10
作者 曹荣光 由世俊 董书芸 《Journal of Central South University》 SCIE EI CAS 2009年第S1期235-238,共4页
The automatic platform gates system (APG) and platform screen doors system (PSD) have been applied in the subways in some cities because of its security. As for the two methods,sometimes,it is difficult to decide whic... The automatic platform gates system (APG) and platform screen doors system (PSD) have been applied in the subways in some cities because of its security. As for the two methods,sometimes,it is difficult to decide which one is better for a certain project. The influence of the train-induced air on subway station and the comfort level of subway station in dynamic and transient conditions was analysized based on experimental data. The comfort level,content of inspiratory particles and noise level show that the environment of subway station with APG can satisfy the requirement of the standard. The air conditioning (A/C) cooling load and ventilation energy consumption of the two kinds of subway stations was predicted with the EnergyPlus program. Because electricity consumption by ventilation equipment increases notably when PSD is used,particularly the electricity consumption by the under platform exhaust (UPE) fan,and thus,ultimately,little difference exists in the overall energy consumption with and without PSD. The APG system is economical for the subway stations of the north cities. And it can satisfy the comfort of passengers for whistle stop. It can be concluded that in north cities APG system is better than PSD system. 展开更多
关键词 COMFORT level SUBWAY side-platform energy consumption automatic PLATFORM GATES
在线阅读 下载PDF
Experimental study on heat exchange of several types of exchangers
11
作者 周志华 赵振华 于洋 《Journal of Central South University》 SCIE EI CAS 2009年第S1期204-208,共5页
Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers bu... Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers buried directly. The result indicates that the heat exchanger makes the best use of structure of building,saves land,reduces the construction cost,and the heat exchanged is obviously more than exchangers buried directly. In winter condition,when W-shape pipe heat exchanger in pile foundation is 50 m deep and diameter is 800 mm,it transfers 1.2-1.3 times as large as the one of single U-shape buried directly at the flow rate of 0.6 m/s,whose borehole diameter is 300 mm. And in summer condition it does about 2.0-2.3 times as that of U-shape one. 展开更多
关键词 ground-coupled source HEAT pump HEAT EXCHANGER in PILE FOUNDATION single U-shape pipe HEAT EXCHANGER BURIED directly HEAT exchange
在线阅读 下载PDF
Value analysis of district heating system with gas-fired peak load boiler in secondary network
12
作者 郑雪晶 穆振英 《Journal of Central South University》 SCIE EI CAS 2009年第S1期178-182,共5页
In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fu... In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fuels of the system,including coal and gas,would cause different environmental impacts. Meanwhile,the reliability of the heating networks would be changed because the peak load regulating boiler could work as a standby heat source. A model for assessment of heating system was established by value analysis to optimize this kind of system. Energy consumption,greenhouse gas emission,pollution emission and system reliability were selected as functional assessment indexes in the model. Weights of each function were determined by analytical hierarchy process (AHP) and experts consultation. Life cycle cost was used as the cost in the model. A real case as an example was discussed to obtain the optimal base load ratio. The result shows that the optimal base load ratio of the case is 0.77. 展开更多
关键词 DISTRICT HEATING VALUE analysis base LOAD RATIO SECONDARY network
在线阅读 下载PDF
上一页 1 下一页 到第