期刊文献+
共找到32篇文章
< 1 2 >
每页显示 20 50 100
An experimental study of dual-energy CT imaging using synchrotron radiation 被引量:1
1
作者 HAO Jia ZHANG Li +1 位作者 XING Yuxiang KANG Kejun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第2期7-11,共5页
The measurement of electron density is important for medical diagnosis and charged particle radiotherapy treatment planning.Traditionally,electron density is obtained by CT imaging using the relationship between CT-nu... The measurement of electron density is important for medical diagnosis and charged particle radiotherapy treatment planning.Traditionally,electron density is obtained by CT imaging using the relationship between CT-number and electron densities established beforehand.However,the measurement is not accurate due to the beam hardening effect.In this paper,we propose a simple and practical electron density acquisition method based on dual-energy CT technique.For each sample,the CT imaging is conducted using two selected X-ray energy from synchrotron radiation.A post-processing dual-energy reconstruction method is used.Linear attenuation coefficients of the scanned samples are obtained by FBP reconstruction.The effective atomic number and electron density are got by solving the dual-energy simultaneous equations.Different phantoms and breast tissues were scanned in this experimental study under 10 keV and 30 keV monochromatic X-rays.The distribution of effective atomic numbers and electron densities of the scanned phantoms were obtained by Dual-energy CT image reconstruction,which agrees well with the theoretical values.Compared with conventional methods,the measurement accuracy is greatly improved, and the measurement error is reduced to about 1%.This experimental study demonstrates that DECT imaging based on synchrotron radiation source is applicable to medical diagnosis for quantitative measurement with high accuracy. 展开更多
关键词 同步辐射光源 CT成像 实验 有效原子序数 电子密度 测量精度 线性衰减系数 CT图像重建
在线阅读 下载PDF
Evaluation of cosmogenic activation of copper and germanium during production in Jinping Underground Laboratory 被引量:8
2
作者 Wei-He Zeng Hao Ma +4 位作者 Ming Zeng Zhi Zeng Qian Yue Jian-Ping Cheng Jun-Li Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第5期70-76,共7页
Intrinsic radiation of materials is one of the major backgrounds for many rare-event search experiments.Thus,the production of pure materials in an underground laboratory is a promising approach for eliminating cosmog... Intrinsic radiation of materials is one of the major backgrounds for many rare-event search experiments.Thus,the production of pure materials in an underground laboratory is a promising approach for eliminating cosmogenic radionuclides.In this paper,we demonstrate a procedure to evaluate the yields of cosmogenic radionuclides in copper and germanium in the second phase of the China Jinping Underground Laboratory.Our results show that for copper and germanium materials,the largest cosmogenic background comes from 3 H and57,58,60Co,and 3 H and 68Ge,respectively,which all have yields on the order of 10-7 kg-1 day-1.The corresponding radioactivities after 90 days pf exposure underground are estimated to be lower than 10-6μBq kg-1. 展开更多
关键词 COSMIC RAYS COSMOGENIC radionuclides UNDERGROUND laboratory MONTE Carlo simulation
在线阅读 下载PDF
Characteristics of terahertz coherent transition radiation generated from picosecond ultrashort electron bunches 被引量:4
3
作者 刘文鑫 唐传祥 黄文会 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第6期221-230,共10页
This paper presents a method of generating terahertz (THz) coherent transition radiation (CTR) from picosecond ultrashort electron bunches including single and train bunches, which are produced by a photocathode r... This paper presents a method of generating terahertz (THz) coherent transition radiation (CTR) from picosecond ultrashort electron bunches including single and train bunches, which are produced by a photocathode radio frequency gun. The radiation characteristics of THz CTR including formation factor and energy spectrum are analysed in detail. With the help of a 2-dimensional particle-in-cell simulation, the radiation characteristics including power, energy and magnetic field are analysed. The results show that the radiation frequency can be adjusted by tuning the repetition frequency of the train bunch and the energy can be enhanced with the train bunches. 展开更多
关键词 coherent transition radiation photocathode radio-frequency gun ultrashort electron bunches PARTICLE-IN-CELL
在线阅读 下载PDF
A review of geometric calibration for different 3-D X-ray imaging systems 被引量:1
4
作者 Yang,Yao Li,Liang Chen,Zhi-Qiang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期194-204,共11页
A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction imag... A precise knowledge of geometry is always pivotal to a 3-D X-ray imaging system,such as computed tomography(CT),digital X-ray tomosynthesis,and computed laminography.To get an accurate and reliable reconstruction image,exact knowledge of geometry is indispensable.Nowadays,geometric calibration has become a necessary step after completing CT system installation.Various geometric calibration methods have been reported with the fast development of 3-D X-ray imaging techniques.In these methods,different measuring methods,calibration phantoms or markers,and calculation algorithms were involved with their respective advantages and disadvantages.This paper reviews the history and current state of geometric calibration methods for different3-D X-ray imaging systems.Various calibration algorithms are presented and summarized,followed by our discussion and outlook. 展开更多
关键词 X射线成像系统 几何校正 三维 计算机断层扫描 计算机层析成像 X射线成像技术 综述 校准方法
在线阅读 下载PDF
Development of a seven-cell S-band standing-wave RF-deflecting cavity for Tsinghua Thomson scattering X-ray source 被引量:1
5
作者 Xian-Cai Lin Hao Zha +4 位作者 Jia-Ru Shi Liu-Yuan Zhou Shuang Liu Jian Gao Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期20-29,共10页
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p... A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented. 展开更多
关键词 Deflecting RF cavity Standing wave Bunchlength measurement Thomson X-ray source
在线阅读 下载PDF
Correction to: Development and preliminary results of a large-pixel two-layer LaBr_(3) Compton camera prototype
6
作者 Ming-Hao Dong Zhi-Yang Yao Yong-Shun Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第1期34-34,共1页
在线阅读 下载PDF
Development of a compact DOI-TOF detector module for high-performance PET systems 被引量:6
7
作者 Qing-Yang Wei Tian-Peng Xu +4 位作者 Tian-Tian Dai Shi Wang Ya-Qiang Liu Yu Gu Tian-Yu Ma 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第4期1-7,共7页
To increase spatial resolution and signal-to-noise ratio in PET imaging,we present in this paper the design and performance evaluation of a PET detector module combining both depth-of-interaction(DOI) and time-offligh... To increase spatial resolution and signal-to-noise ratio in PET imaging,we present in this paper the design and performance evaluation of a PET detector module combining both depth-of-interaction(DOI) and time-offlight(TOF) capabilities.The detector module consists of a staggered dual-layer LYSO block with2 mm × 2 mm × 7 mm crystals.MR-compatible SiPM sensors(MicroFJ-30035-TSV,SensL) are assembled into an 8× 8 array.SiPM signals from both fast and slow outputs are read out by a 128-channel ASIC chip.To test its performance,a flood histogram is acquired with a ^(22)Na point source on top of the detector,and the energy resolution and the coincidence resolving time(CRT) value for each individual crystal are measured.The flood histogram shows excellent crystal separation in both layers.The average energy resolution at 511 keV is 14.0 and 12.7%at the bottom and top layers,respectively.The average CRT of a single crystal is 635 and 565 ps at the bottom and top layers,respectively.In conclusion,the compact DOI-TOF PET detector module is of excellent crystal identification capability,good energy resolution and reasonable time resolution and has promising application prospective in clinical TOF PET,PET/MRI,and brain PET systems. 展开更多
关键词 POSITRON emission TOMOGRAPHY SIPM Depth of interaction (DOI) TIME-OF-FLIGHT (TOF)
在线阅读 下载PDF
Influence factors of two dimensional position map on photomultiplier detector block designed by quadrant sharing technique 被引量:3
8
作者 WEI Qingyang WANG Shi Ma Tianyu MA Fei DAI Tiantian XU Tianpeng WU Zhaoxia JIN Yongjie LIU Yaqiang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第4期224-229,共6页
The position decoding accuracy and the spatial resolution of positron emission tomography detectors are greatly influenced by the performance of the two-dimensional position map,including the gain uniformity of photom... The position decoding accuracy and the spatial resolution of positron emission tomography detectors are greatly influenced by the performance of the two-dimensional position map,including the gain uniformity of photomultiplier tube (PMT),the baseline offset of the PMT signals and the accuracy of analogue to digital converter (ADC).In this work,a PMT-quadrant sharing detector was designed.Two data acquisition platforms are employed to conduct the influence factors on the two-dimensional position map performances,one was that the waveforms of the PMT signals were scanned by the sequence acquisition mode based on the oscilloscope of LeCroy waveRunner 204MXi-A,and another was a self-developed high speed ADC data acquisition module.Results show that the event decoding positions were concentrated on the PMT with higher gain,the position map was distorted at the baseline offset of signal,and the cross-line artifacts were caused by the insufficient ADC sampling bit for a larger size position map.All the parameters need be adjusted properly to stabilize a real system,and the flexible oscilloscope platform can be used to design the detector block and the other platform with high ADC accuracy.Likely,the electrical circuit with a proper ADC accuracy adjusts the PMT gains and baseline offsets. 展开更多
关键词 光电倍增管 三维位置 影响因素 共享技术 地图 设计 正电子发射断层扫描 象限
在线阅读 下载PDF
Application of the asynchronous advantage actor–critic machine learning algorithm to real-time accelerator tuning 被引量:3
9
作者 Yun Zou Qing-Zi Xing +4 位作者 Bai-Chuan Wang Shu-Xin Zheng Cheng Cheng Zhong-Ming Wang Xue-Wu Wang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期133-141,共9页
This paper describes a real-time beam tuning method with an improved asynchronous advantage actor–critic(A3C)algorithm for accelerator systems.The operating parameters of devices are usually inconsistent with the pre... This paper describes a real-time beam tuning method with an improved asynchronous advantage actor–critic(A3C)algorithm for accelerator systems.The operating parameters of devices are usually inconsistent with the predictions of physical designs because of errors in mechanical matching and installation.Therefore,parameter optimization methods such as pointwise scanning,evolutionary algorithms(EAs),and robust conjugate direction search are widely used in beam tuning to compensate for this inconsistency.However,it is difficult for them to deal with a large number of discrete local optima.The A3C algorithm,which has been applied in the automated control field,provides an approach for improving multi-dimensional optimization.The A3C algorithm is introduced and improved for the real-time beam tuning code for accelerators.Experiments in which optimization is achieved by using pointwise scanning,the genetic algorithm(one kind of EAs),and the A3C-algorithm are conducted and compared to optimize the currents of four steering magnets and two solenoids in the low-energy beam transport section(LEBT)of the Xi’an Proton Application Facility.Optimal currents are determined when the highest transmission of a radio frequency quadrupole(RFQ)accelerator downstream of the LEBT is achieved.The optimal work points of the tuned accelerator were obtained with currents of 0 A,0 A,0 A,and 0.1 A,for the four steering magnets,and 107 A and 96 A for the two solenoids.Furthermore,the highest transmission of the RFQ was 91.2%.Meanwhile,the lower time required for the optimization with the A3C algorithm was successfully verified.Optimization with the A3C algorithm consumed 42%and 78%less time than pointwise scanning with random initialization and pre-trained initialization of weights,respectively. 展开更多
关键词 REAL-TIME BEAM tuning Parameter optimization ASYNCHRONOUS ADVANTAGE actor–critic algorithm Low-energy BEAM transport
在线阅读 下载PDF
Study of a GPU-based parallel computing method for the Monte Carlo program 被引量:2
10
作者 罗志飞 邱睿 +3 位作者 李明 武祯 曾志 李君利 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第A01期27-30,共4页
关键词 并行计算方法 蒙特卡罗程序 GPU GEANT4 模拟程序 蒙特卡洛方法 并行处理能力 图形处理单元
在线阅读 下载PDF
Fabrication,tuning,and high-gradient testing of an X-band traveling-wave accelerating structure for VIGAS 被引量:2
11
作者 Xian-Cai Lin Hao Zha +6 位作者 Jia-Ru Shi Qiang Gao Jia-Yang Liu Liu-Yuan Zhou Jian Gao Huai-Bi Chen Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第8期77-88,共12页
X-band high-gradient linear accelerators are a challenging and attractive technology for compact electron linear-accelerator facilities.The Very Compact Inverse Compton Scattering Gamma-ray Source(VIGAS)program at Tsi... X-band high-gradient linear accelerators are a challenging and attractive technology for compact electron linear-accelerator facilities.The Very Compact Inverse Compton Scattering Gamma-ray Source(VIGAS)program at Tsinghua University will utilize X-band high-gradient accelerating structures to boost the electron beam from 50 to 350 MeV over a short distance.A constant-impedance traveling-wave structure consisting of 72 cells working in the 2π/3 mode was designed and fabricated for this project.Precise tuning and detailed measurements were successfully applied to the structure.After 180 h of conditioning in the Tsinghua high-power test stand,the structure reached a target gradient of 80 MV/m.The breakdown rate versus gradient of this structure was measured and analyzed. 展开更多
关键词 Traveling-wave accelerating structure X-band high gradient Tuning method High-power test
在线阅读 下载PDF
Design, fabrication, and testing of low-group-velocity S-band traveling-wave accelerating structure 被引量:2
12
作者 Xian-Cai Lin Hao Zha +6 位作者 Jia-Ru Shi Liu-Yuan Zhou Yi-Fan Liang Jian Gao Qiang Gao Huai-Bi Chen Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第11期133-143,共11页
To implement the Tsinghua Thomson Scattering X-ray Source upgrade plan and the Very Compact Inverse Compton Scattering Gamma-ray Source (VIGAS) program, a new 1.5-m traveling-wave accelerating structure was designed t... To implement the Tsinghua Thomson Scattering X-ray Source upgrade plan and the Very Compact Inverse Compton Scattering Gamma-ray Source (VIGAS) program, a new 1.5-m traveling-wave accelerating structure was designed to replace the old 3-m SLAC-type structure with the aim of increasing the accelerating gradient from15 to 30 MV/m. The new type of structure works in the 3π/4 mode with a comparatively low group velocity varying from 0.007c to 0.003c to increase the accelerating gradient at a given power. An elliptical iris was employed to reduce the surface field enhancement. The filling process of the low-group-velocity structure was analyzed using a circuit model. After fabrication, the structure was precisely tuned using the non-contact tuning method, followed by detailed low-power radiofrequency measurements. The structure was first installed and utilized at a beamline for the terahertz experiment at Tsinghua University. After 120 h of conditioning, it is now operating at a gradient of 24.2 MV/m and a 20.7-MW input power, with the klystron operating at its full power. It is expected to generate an accelerating gradient of 30 MV/m when the klystron power is upgraded to 30 MW in the near future. 展开更多
关键词 Traveling-wave accelerating structure Cavity optimization Tuning method High-power test
在线阅读 下载PDF
Analytic RF design of a linear accelerator with a SLED-Ⅰ type RF pulse compressor 被引量:2
13
作者 Jia-Yang Liu Jia-Ru Shi +4 位作者 Hao Zha Alexej Grudiev Ping Wang Ying-Chao Du Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第11期12-22,共11页
This study presents the RF design of a linear accelerator(linac)operated in single-bunch mode.The accelerator is powered by a compressed RF pulse produced from a SLED-I type RF pulse compressor.The compressed RF pulse... This study presents the RF design of a linear accelerator(linac)operated in single-bunch mode.The accelerator is powered by a compressed RF pulse produced from a SLED-I type RF pulse compressor.The compressed RF pulse has an unflattened shape with a gradient distribution which varies over the structure cells.An analytical study to optimize the accelerating structure together with the RF pulse compressor is performed.The optimization aims to maximize the efficiency by minimizing the required RF power from the generator for a given average accelerating gradient.The study shows that,owing to the compressed RF pulse shape,the constant-impedance structure has a similar efficiency to the optimal structure using varying iris apertures.The constant-impedance structure is easily fabricated and is favorable for the design of a linac with a pulse compressor.We utilize these findings to optimize the RF design of a X-band linac using the constant-impedance accelerating structure for the Tsinghua Thomson X-ray source facility. 展开更多
关键词 X-band linac High gradient structure RF pulse compressor Thomson X-ray source Single-bunch mode
在线阅读 下载PDF
A practical image reconstruction and processing method for symmetrically off-center detector CBCT system 被引量:1
14
作者 HAO Jia ZHANG Li +2 位作者 LI Liang CHEN Zhiqiang KANG Kejun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第4期17-22,共6页
CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the... CBCT scanners have been widely used in angiography,radiotherapy guidance,mammography and oral maxillofacial imaging.To cut detector size,reduce manufacturing costs and radiation dose while keeping a reasonable FOV,the flat panel detector can be placed off-center horizontally.This scanning configuration extends the FOV effectively.However,each projection is transversely truncated,bringing errors and artifacts in reconstruction.In this paper,a simple but practical method is proposed for this scanning geometry based on truncation compensation and the modified FDK algorithm.Numerical simulations with jaw phantom were conducted to evaluate the accuracy and practicability of the proposed method.A novel CBCT system for maxillofacial imaging is used for clinical test,which is equipped with an off-center small size flat panel detector.Results show that reconstruction accuracy is acceptable for clinical use,and the image quality appears sufficient for specific diagnostic requirements.It provides a novel solution for clinical CBCT system,in order to reduce radiation dose and manufacturing cost. 展开更多
关键词 CT系统 检测器 CB 图像重建 CT扫描仪 平板探测器 对称 辐射剂量
在线阅读 下载PDF
Performance simulation and structure design of Binode CdZnTe gamma-ray detector 被引量:1
15
作者 牛莉博 李玉兰 +4 位作者 张岚 傅楗强 江灏 何彬 李元景 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第1期53-58,共6页
A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma ... A new electrode structure CdZnTe(Cadmium Zinc Telluride) detector named Binode CdZnTe has been proposed in this paper.Together with the softwares of MAXWELL,GEANT4,and ROOT,the charge collection process and its gamma spectrum of the detector have been simulated and the detector structure has been optimized.In order to improve its performance further,Compton scattering effect correction has been used.The simulation results demonstrate that with refined design and Compton scattering effect correction,Binode CdZnTe detectors is capable of achieving 3.92%FWHM at 122 keV,and 1.27%FWHM at 662 keV.Compared with other single-polarity(electron-only) detector configurations,Binode CdZnTe detector offers a cost effective and simple structure alternative with comparable energy resolution. 展开更多
关键词 结构设计 性能模拟 检测器 阳极 ZNTE 碲锌镉探测器 Γ射线 CD
在线阅读 下载PDF
Development and preliminary results of a large-pixel two-layer LaBr_(3) Compton camera prototype 被引量:1
16
作者 Ming-Hao Dong Zhi-Yang Yao Yong-Shun Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期100-114,共15页
Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because L... Lanthanum bromide(LaBr_(3))crystal has a high energy resolution and time resolution and has been used in Compton cameras(CCs)over the past few decades.However,LaBr_(3) crystal arrays are difficult to process because LaBr_(3) is easy to crack and break;thus,few LaBr_(3)-based CC prototypes have been built.In this study,we designed and fabricated a large-pixel LaBr_(3) CC prototype and evaluated its performance with regard to position,energy,and angular resolution.We used two 10×10 LaBr_(3) crystal arrays with a pixel size of 5 mm×5 mm,silicon photomultipliers(SiPMs),and corresponding decoding circuits to construct our prototype.Additionally,a framework based on a Voronoi diagram and a lookup table was developed for list-mode projection data acquisition.Monte Carlo(MC)simulations based on Geant4 and experiments were conducted to evaluate the performance of our CC prototype.The lateral position resolution was 5 mm,and the maximum deviation in the depth direction was 2.5 and 5 mm for the scatterer and absorber,respectively.The corresponding measured energy resolu-tions were 7.65%and 8.44%,respectively,at 511 keV.The experimental results of ^(137)Cs point-like sources were consistent with the MC simulation results with regard to the spatial positions and full widths at half maximum(FWHMs).The angular resolution of the fabricated prototype was approximately 6°when a point-like ^(137)Cs source was centrally placed at a distance of 5 cm from the scatterer.We proposed and investigated a large-pixel LaBr_(3) CC for the first time and verified its feasibility for use in accurate spatial positioning of radiative sources with a high angular resolution.The proposed CC can satisfy the requirements of radiative source imaging and positioning in the nuclear industry and medical applications. 展开更多
关键词 Compton camera Large pixel Gamma camera LaBr_(3)detector Prototype evaluation
在线阅读 下载PDF
Design,fabrication,and testing of an X-band 9-MeV standing-wave electron linear accelerator 被引量:1
17
作者 Jian Gao Hao Zha +5 位作者 Jia-Ru Shi Qiang Gao Xian-Cai Lin Fang-Jun Hu Qing-Zhu Li Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第7期219-230,共12页
In this study,an X-band standing-wave biperiodic linear accelerator was developed for medical radiotherapy that can accel-erate electrons to 9 MeV using a 2.4-MW klystron.The structure works atπ/2 mode and adopts mag... In this study,an X-band standing-wave biperiodic linear accelerator was developed for medical radiotherapy that can accel-erate electrons to 9 MeV using a 2.4-MW klystron.The structure works atπ/2 mode and adopts magnetic coupling between cavities,generating the appropriate adjacent mode separation of 10 MHz.The accelerator is less than 600-mm long and constitutes four bunching cells and 29 normal cells.Geometry optimizations,full-scale radiofrequency(RF)simulations,and beam dynamics calculations were performed.The accelerator was fabricated and examined using a low-power RF test.The cold test results showed a good agreement with the simulation and actual measurement results.In the high-power RF test,the output beam current,energy spectrum,capture ratio,and spot size at the accelerator exit were measured.With the input power of 2.4 MW,the pulse current was 100 mA,and the output spot root-mean-square radius was approximately 0.5 mm.The output kinetic energy was 9.04 MeV with the spectral FWHM of 3.5%,demonstrating the good performance of this accelerator. 展开更多
关键词 Standing-wave accelerating structure RF analysis Thermal DC gun Low-power RF test High-power experiment
在线阅读 下载PDF
Analysis and simulation of the tune ripple effect on beam spill ripple in RF-KO slow extraction 被引量:1
18
作者 Wen-Bo Ye Hong-Juan Yao +2 位作者 Shu-Xin Zheng Xia-Ling Guan Xue-Wu Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第5期91-101,共11页
Tune ripple has a significant influence on beam spill ripple in RF-knockout(RF-KO)slow extraction.In this study,a model was proposed to explain how the tune ripple affects the beam spill in RF-KO slow extraction;conse... Tune ripple has a significant influence on beam spill ripple in RF-knockout(RF-KO)slow extraction.In this study,a model was proposed to explain how the tune ripple affects the beam spill in RF-KO slow extraction;consequently,a simulation was performed using the lattice of the Xi’an Proton Application Facility(XiPAF)synchrotron to verify the model.The simulation demonstrates that the tune ripple influences the beam spill in two ways.On the one hand,the tune ripple causes a direct fluctuation in the separatrix area,which induces beam spill ripple.On the other hand,the tune ripple influences the emittance growth rate in RF-knockout slow extraction.These two aspects simultaneously contribute to the beam spill ripple. 展开更多
关键词 RF-knockout slow extraction Synchrotron Tune ripple Power supply ripple Beam spillripple
在线阅读 下载PDF
Effects of systematic octupole coupling resonances 被引量:1
19
作者 Hong-Jin Zeng Shyh-Yuan Lee +4 位作者 Shu-Xin Zheng Hong-Juan Yao Xue-Wu Wang Hui Ning Xiao-Jun Meng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第7期10-15,共6页
The Xi’an proton accelerator facility synchrotron lattice has a systematic fourth-order resonance. The systematic octupole component in dipole magnets is found to have no adverse effect on the dynamic aperture in mul... The Xi’an proton accelerator facility synchrotron lattice has a systematic fourth-order resonance. The systematic octupole component in dipole magnets is found to have no adverse effect on the dynamic aperture in multiparticle tracking. The frequency map shows particles locked onto the 2v x 2v z-0 resonance. However, we will show that the instantaneous betatron tunes can vary widely around the resonance line for particles locked onto the resonance. 展开更多
关键词 OCTUPOLE COUPLING RESONANCE DYNAMIC APERTURE XiPAF
在线阅读 下载PDF
Analysis and optimization of energy resolution of neutron-TPC
20
作者 黄孟 李玉兰 +2 位作者 牛莉博 李金 李元景 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第4期102-108,共7页
Neutron-TPC(n TPC)is a fast neutron spectrometer based on GEM-TPC(Gas Electron Multiplier-Time Projection Chamber)and expected to be used in nuclear physics,nuclear reactor operation monitoring,and thermonuclear fusio... Neutron-TPC(n TPC)is a fast neutron spectrometer based on GEM-TPC(Gas Electron Multiplier-Time Projection Chamber)and expected to be used in nuclear physics,nuclear reactor operation monitoring,and thermonuclear fusion plasma diagnostics.By measuring the recoiled proton energy and slopes of the proton tracks,the incident neutron energy can be deduced.It has higher n/γseparation ability and higher detection efficiency than conventional neutron spectrometers.In this paper,neutron energy resolution of n TPC is studied using the analytical method.It is found that the neutron energy resolution is determined by 1)the proton energy resolution(σEp/Ep),and 2)standard deviation of slopes of the proton tracks caused by multiple Coulomb scattering(σk(scattering))and by the track fitting accuracy(σk(fit)).Suggestions are made for optimizing energy resolution of n TPC.Proper choices of the cut parameters of reconstructed proton scattering angles(θcut),the number of fitting track points(N),and the working gas help to improve the neutron energy resolution. 展开更多
关键词 能量分辨率 TPC 优化分析 中子 PROJECTION multiple REACTOR TRACK
在线阅读 下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部