期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Langmuir probe diagnostics in multi-Maxwellian EEDF plasmas
1
作者 YIP Chi-shung JIN Chenyao +1 位作者 JIANG Di ZHANG Wei 《推进技术》 北大核心 2025年第6期254-274,共21页
This article provides a short review on the importance of the detailed analysis of a Langmuir probe I-V trace in a multi-Maxwellian plasma,and discuss proper procedures analyzing Langmuir probe I-V traces in bi-Maxwel... This article provides a short review on the importance of the detailed analysis of a Langmuir probe I-V trace in a multi-Maxwellian plasma,and discuss proper procedures analyzing Langmuir probe I-V traces in bi-Maxwellian and triple-Maxwellian Electron Energy Distribution Function(EEDF)plasmas.Discus⁃sion and demonstration of procedures include the treatment of the ion saturation current,electron saturation cur⁃rent,space-charge effects on the I-V trace,and most importantly how to properly isolate and fit for each electron group present in an I-V trace reflecting a mult-Maxwellian EEDF,as well as how having a multi-Maxwellian EEDF affects the procedures of treating the ion and electron saturation currents.Shortcomings of common improp⁃er procedures are discussed and demonstrated with simulated I-V traces to show how these procedures gives false measurements. 展开更多
关键词 Plasma diagnostics Langmuir probes EEDFs I-V characteristics Electron temperature
在线阅读 下载PDF
Seismic response analysis for equatorial diagnostic port plug of international thermonuclear experimental reactor 被引量:1
2
作者 余东满 姚达毛 +5 位作者 谢韩 鲍立曼 许铁军 彭玉华 刘素梅 杨庆喜 《Journal of Central South University》 SCIE EI CAS 2009年第1期112-118,共7页
Modal analysis and seismic response analysis were carried out for the equatorial diagnostic port plug of international thermonuclear experimental reactor (ITER). The aim of the theoretical analysis is to verify struct... Modal analysis and seismic response analysis were carried out for the equatorial diagnostic port plug of international thermonuclear experimental reactor (ITER). The aim of the theoretical analysis is to verify structural strength and reliability of the device. The working condition includes one-dimensional seismic wave and two-dimensional seismic wave. Modal analysis of the device shows that primary vibration is inclined to occur in low-order modes. The horizontal (X-direction, Y-direction) maximum vibration appears at the first and the fourth eigen modes, with the natural frequency of 70.59 and 215.88 Hz respectively, and the vertical (Z-direction) primary vibration appears at the second eigen mode with the natural frequency of 82.85 Hz. According to the results of the finite element analysis (FEA) program, the weak portions of the device are distributed in the joint of port body with blanket shielding module (BSM) and inner side wall of ribbed plate for lifting flange, the maximum von Mises stress is 14.8 MPa with the Y-direction seismic wave. In accordance with the design criteria, the destructive effect is far below the failure boundary, and the structural reliability of the equatorial diagnostic port plug can meet the requirements of the design specifications. 展开更多
关键词 diagnostic port plug seismic response finite element analysis nuclear fusion
在线阅读 下载PDF
室温长波光导探测器研究
3
作者 Jozef Piotrowski 《红外研究》 CSCD 北大核心 1990年第1期1-6,共6页
从理论和实验上详细研究了室温长波HgCdTe光导探测器,提出了室温光导半导体的广义优值,计算了10.6μm HgCdTe探测器的优值和极限性能与组分和掺杂的关系。用HgCdTe外延层制作了光导探测器,描述了它的性能。结果表明10.6μm室温光导探测... 从理论和实验上详细研究了室温长波HgCdTe光导探测器,提出了室温光导半导体的广义优值,计算了10.6μm HgCdTe探测器的优值和极限性能与组分和掺杂的关系。用HgCdTe外延层制作了光导探测器,描述了它的性能。结果表明10.6μm室温光导探测器的最佳探测率可高于1×10~8cmHz^(1/2)/W,已接近一般的热敏型探测器性能。 展开更多
关键词 HGCDTE 室温光导探测器 优值 极限性能 碲镉汞
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部