Numerical simulation on heat transfer performance of vertical U-tube with different borehole fill materials 被引量:2
1
作者 刘方 郭涛 +1 位作者 王勇 翁庙成 《Journal of Central South University of Technology》 EI 2006年第3期234-237,共4页
Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on th... Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials. 展开更多
关键词 vertical U-tube heat exchanger ground-source heat pump numerical simulation
在线阅读 下载PDF
Applied analysis of ventilation technology in residential buildings in Changjiang river valley
2
作者 杨露露 卢军 +1 位作者 王曦 甘灵丽 《Journal of Central South University》 SCIE EI CAS 2009年第S1期197-203,共7页
Making the use of ventilation technology may decrease building energy consumption,improve indoor thermal environment,and ameliorate indoor air quality. Combining with the meteorological characteristics in the Changjia... Making the use of ventilation technology may decrease building energy consumption,improve indoor thermal environment,and ameliorate indoor air quality. Combining with the meteorological characteristics in the Changjiang river valley and focusing on Chongqing,this work makes an applied analysis of the feasibility of intermittent mechanical ventilation. By comparison of various ventilation modes,it gives a summary of the suitable ventilation ways for different weather conditions with the combination of testing data and experimental data. 展开更多
关键词 CHANGJIANG RIVER VALLEY BUILDING ventilation ventilation MODE EXPERIMENTAL analysis
在线阅读 下载PDF
Building cooling by night-time ventilation
3
作者 卢军 王曦 甘灵丽 《Journal of Central South University》 SCIE EI CAS 2009年第S1期84-88,共5页
Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but a... Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but also arcology energy technology based on green and sustainable thought should be advocated. Considering the ever growing energy consumption of residential buildings,intermittent ventilation is a solution to saving energy consumption and improving indoor thermal comfort. Aiming at reducing indoor air temperature by intermittent ventilation and decrease energy consumption of air conditioning system,with the help of DeST (Designer's Simulation Toolkit) this paper analyzes the characteristics of air conditioning load and year round air conditioning time in Chongqing located in hot summer and cold winter zone,obtains the amount of energy consumption saved at different ventilation rates,and recommends suitable ventilation rate in hot summer and cold winter zone. 展开更多
关键词 RESIDENTIAL building INTERMITTENT ventilation AIR CONDITIONING LOAD AIR CONDITIONING time
在线阅读 下载PDF
Investigation on balcony plume entrainment
4
作者 刘方 NIELSEN P V +1 位作者 HEILSELBERG P BROHUS H 《Journal of Central South University》 SCIE EI CAS 2009年第S1期105-110,共6页
An investigation on the scenarios of the spill plume and its equation was presented,including two aspects,i.e.,the small-scale experiment and the numerical simulation. Two balcony spill plume models are assessed by co... An investigation on the scenarios of the spill plume and its equation was presented,including two aspects,i.e.,the small-scale experiment and the numerical simulation. Two balcony spill plume models are assessed by comparing with the fire dynamic simulation (FDS) and small scale model experiment results. Besides validating the spill model by experiments,the effect of different fire locations on balcony plume is also discussed. The results show that the balcony equation in NFPA gives good predictions on the mass flow rate. And the balcony plume entrainment coefficient is independent of the fire location. This investigation is useful for the fire engineers in designing smoke control systems. 展开更多
关键词 FIRE PLUME ENTRAINMENT ATRIUM