In recent years,along with the rapid expansion of power grids,the increasing complication of grid structures,and the development of smart grids and energy technologies,the lightning protection of power grids becomes i...In recent years,along with the rapid expansion of power grids,the increasing complication of grid structures,and the development of smart grids and energy technologies,the lightning protection of power grids becomes increasingly prominent.Power grids of China have acquired significant achievements on lightning protection technologies,which are reviewed in this paper.A technical route of lightning protection is introduced in detail; it allows us to find problems through detection and measurement of lightning,to analyze problems through evaluation and simulation of lightning,to solve problems through lightning protection measures,and to prevent problems through hazard risk warning of lightning.Following the route,the technical breakthroughs of these four aspects in China are presented,including the chinese lightning detection network(CLDN),natural lightning observations,lightning faults detection at transmission lines,lightning current measurements,progresses in lightning distribution maps,lightning fault replays,lightning hazard risk evaluations,and lightning simulated experiments,as well as novel lightning protection measures.The practical devices and systems corresponding to the technologies mentioned above are also introduced and discussed.Due to the progress of lightning protection technologies in recent years,despite the rapidly growing length of transmission lines in China,the lightning accident rate is controlled at a certain level.展开更多
In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calcu...In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calculated with finite element method for field simulation.Tests on artificial pollution insulators are conducted to study the 50% withstand voltage U50 of artificial pollution suspension insulators under different NSDD(non-soluble deposit density)and asymmetric pollution on the top/bottom surface,and study the change of leakage current with air humidity under different voltage and different ESDD(equivalent salt deposit density).The result shows that asymmetric top/bottom surface pollution has a greater impact on the insulator electrical field distribution,and the leakage current will jump under low air humidity,if had large ESDD,which has practical meanings to the anti-pollution design of the transmission line under different pollution levels across the country.展开更多
The impacts of large-scale grid-connected wind farm on direct-driven permanent magnet synchronous generator(PMSG)type are discussed on the small signal stability performances of power systems.Firstly,a simplified prac...The impacts of large-scale grid-connected wind farm on direct-driven permanent magnet synchronous generator(PMSG)type are discussed on the small signal stability performances of power systems.Firstly,a simplified practical model of wind farm of PMSG type is derived for analyzing small signal stability.The rotor-fluxoriented control strategy is applied to the modelling of PMSG.Secondly,the framework of small signal stability analysis incorporating wind farm of PMSG type is built.Finally,the different simulation scenarios based on the IEEE 3-generator-9-bus test system as benchmark are designed to conduct the eigenvalue analysis and to assess the impacts of wind farm of PMSG type on power system small signal stability.Some conclusions are drawn with simulation results.展开更多
Besides common characteristics of wind power,there are some special characteristics in China power system,including large-scale,long distance transmission and lack of flexible regulating power sources.These special ch...Besides common characteristics of wind power,there are some special characteristics in China power system,including large-scale,long distance transmission and lack of flexible regulating power sources.These special characteristics make power dispatch more challenging in China.Many studies have been carried out and some improvements are presented including wind power monitoring and control as well as evaluation of wind power integration capabilities.As a demonstration project,the technologies are integrated into the energy management system and are implemented in the Northwest China power system.They provide effective measures for wind power dispatch in the grid.展开更多
The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodica...The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodically time-varying mesh stiffness, the nonlinear tooth backlash, the lump-parameter model of the gear system is developed with one rotational and two translational freedoms of each gear. The eigen-values and eigenvectors are derived and analyzed on the basis of the real modal theory. The sensitivities of natural frequencies to design parameters including supporting and meshing stiffnesses, gear masses, and moments of inertia by the direct differential method are also calculated. The results show the quantitative and qualitative impact of the parameters to the natural characteristics of the gear system. Furthermore, the periodic steady state solutions are obtained by the numerical approach based on the nonlinear model. These results are employed to gain insights into the primary controlling parameters, to forecast the severity of the dynamic response, and to assess the acceptability of the gear design.展开更多
Forest fire accidents caused by distribution line faults occur frequently,resulting in heavy impacts on people’s safety and social and economic development.Currently,there are few risk assessments for forest fires in...Forest fire accidents caused by distribution line faults occur frequently,resulting in heavy impacts on people’s safety and social and economic development.Currently,there are few risk assessments for forest fires induced by over-head distribution lines,and existing assessment methods may have difficulties in data acquisition.On this basis,a novel as-sessment framework based on an analytic hierarchy process,a Bayesian network and a Fussel-Vesely importance metric is proposed in this paper.The framework combines field research and historical operation and maintenance data to assess the regional-scale risk of forest fires induced by overhead distribution lines to derive the probability of forest fires and to identify high-risk lines and key hazard events in the assessment region.Finally,taking the southern Anhui region as an ex-ample,the annual fire probability of forest fires induced by overhead distribution lines in the southern Anhui region is 5.88%,and rectification measures are proposed.This study provides management with a complete assessment framework that optimizes the difficulty of data collection and allows for additional targeted corrective measures to be proposed for the entire region and route on the basis of the assessment results.展开更多
It is one of the most effective ways to use laboratory long air gap discharges for investigating the fundamental process involved in the lightning strike.During the 1960s and the 1970s,the electro-geometrical method(E...It is one of the most effective ways to use laboratory long air gap discharges for investigating the fundamental process involved in the lightning strike.During the 1960s and the 1970s,the electro-geometrical method(EGM)and the rolling sphere method were developed base on the breakdowncharacteristics of negative long spark discharges,which have been widely used to design the lightning shielding system of transmission lines and structures.In recent years,the scale of the power facilities is increased dramatically with the rising of power grid's voltage level.The impact of upward connecting leader launched from those large-scale facilities on the lightning shielding performance cannot be neglected;otherwise,the validity of the EGM in the lightning shielding design of EHV and UHV transmission lines will be challenged.The research evolutions on the lightning striking distance,the lightning simulation experiments and the positive upward connecting leader process by using laboratory long sparks are reviewed and discussed in this paper.展开更多
The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments wi...The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.展开更多
The stochastic convergence of the cubature Kalmanfilter with intermittent observations (CKFI) for general nonlinearstochastic systems is investigated. The Bernoulli distributed ran-dom variable is employed to descri...The stochastic convergence of the cubature Kalmanfilter with intermittent observations (CKFI) for general nonlinearstochastic systems is investigated. The Bernoulli distributed ran-dom variable is employed to describe the phenomenon of intermit-tent observations. According to the cubature sample principle, theestimation error and the error covariance matrix (ECM) of CKFIare derived by Taylor series expansion, respectively. Afterwards, itis theoretically proved that the ECM will be bounded if the obser-vation arrival probability exceeds a critical minimum observationarrival probability. Meanwhile, under proper assumption corre-sponding with real engineering situations, the stochastic stabilityof the estimation error can be guaranteed when the initial estima-tion error and the stochastic noise terms are sufficiently small. Thetheoretical conclusions are verified by numerical simulations fortwo illustrative examples; also by evaluating the tracking perfor-mance of the optical-electric target tracking system implementedby CKFI and unscented Kalman filter with intermittent observa-tions (UKFI) separately, it is demonstrated that the proposed CKFIslightly outperforms the UKFI with respect to tracking accuracy aswell as real time performance.展开更多
Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the sta...Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.展开更多
Saturator is one of the core components of humid air turbine (HAT) and is the main feature of HAT making it different from other gas turbine cycles. Due to the lack of sufficient experience in commercial plant opera...Saturator is one of the core components of humid air turbine (HAT) and is the main feature of HAT making it different from other gas turbine cycles. Due to the lack of sufficient experience in commercial plant operation, HAT cycle has a great demand for modeling and simulation of the system and its components, especially the saturator, to provide reference for system design and optimization. The conventional saturator models are usually based on the theory of heat and mass transfer, which need two accurate coefficients to ensure convincing results. This work proposes a global heat and mass transfer coefficient based on cooling tower technology to model the saturator in small-scale HAT cycle. Compared with the experimental data, the simulation results show that the proposed model well predicts the dynamic humidity and temperature distribution characteristics of saturator at low air pressure and temperature.展开更多
Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle...Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle provides a new choice for aeroderivative gas turbine because the humidification process does not require high temperature.Existing HAT cycle plants are all based on single-shaft gas turbines due to their simple structures,therefore converting aeroderivative three-shaft gas turbine into HAT cycle still lacks sufficient research.This paper proposes a HAT cycle model on a basis of an aeroderivative three-shaft gas turbine.Detailed HAT cycle modelling of saturator,gas turbine and heat exchanger are carried out based on the modular modeling method.The models are verified by simulations on the aeroderivative three-shaft gas turbine.Simulation results show that the studied gas turbine with original size and characteristics could not reach the original turbine inlet temperature because of the introduction of water.However,the efficiency still increases by 0.16%when the HAT cycle runs at the designed power of the simple cycle.Furthermore,simulations considering turbine modifications show that the efficiency could be significantly improved.The results obtained in the paper can provide reference for design and analysis of HAT cycle based on multi-shaft gas turbine especially the aeroderivative gas turbine.展开更多
High-speed impact threats and terrorist actions on the battlefield require the development of more effective protective materials and structures,and various protective structure is designed according their energy-abso...High-speed impact threats and terrorist actions on the battlefield require the development of more effective protective materials and structures,and various protective structure is designed according their energy-absorbing characteristics.In this research,the deformation behavior,microscopic failure modes and energy absorption characteristics of re-entrant hexagonal structure,regular hexagonal structure and regular quadrilateral structure are studied under different strain rates impact.The re-entrant hexagonal structure forms a“X”-shaped deformation zone,the regular quadrilateral and regular hexagonal structure form an“I”-shaped deformation zone.The microscopic appearance of the section is a mixed fracture form.The effects of the topological shape,cell angle,and cell height on the impact behavior of the structure were evaluated.When the cell height is fixed and the cell angle is changed,the energy absorption of the structure increase and then decrease as the relative density increase.The mechanical properties of the structure are optimal when the relative density is about 18.6%and the cell angle is22.5°.When the cell angle is fixed and the cell height is changed,as the relative density increases,the energy absorption of the structure gradually increases.The regular quadrilateral structure and the reentrant hexagonal structure experienced clear strain rate effects under dynamic impact conditions;the regular hexagonal structure did not exhibit obvious strain rate effects.The results presented herein provide a basis for further rational design and selection of shock-resistant protective structures that perform well in high-speed impact environments.展开更多
The space charge behavior of a dielectric under HVDC is influenced by the charge trap energy distribution in it. Hence, we in- vestigated the charge trap distributions in several kinds of typical polymer materials usi...The space charge behavior of a dielectric under HVDC is influenced by the charge trap energy distribution in it. Hence, we in- vestigated the charge trap distributions in several kinds of typical polymer materials using thermally stimulated discharge (TSD) and photo-stimulated discharge (PSD) methods, respectively. The experimental results show that,there is a significant difference between the trap energy distributions obtained by the two methods, but the difference decreases with the increase of the melting point of polymers. This is attributed to the change of the trap center environment during TSD caused by the increasing movements of both main chains and branched chains in polymers. PSD method is more accurate for investigating charge trap distribution in dielectrics, especially for polymers with low melting points.展开更多
The optimization of black-start decision-making plays an important role in the rapid restoration of a power system after a major failure/outage.With the introduction of the concept of smart grids and the development o...The optimization of black-start decision-making plays an important role in the rapid restoration of a power system after a major failure/outage.With the introduction of the concept of smart grids and the development of real-time communication networks,the black-start decision-makers are no longer limited to only one or a few power system experts such as dispatchers,but rather a large group of professional people in practice.The overall behaviors of a large decision-making group of decision-makers/experts are more complicated and unpredictable.However,the existing methods for black-start decision-making cannot handle the situations with a large group of decision-makers.Given this background,a clustering algorithm is presented to optimize the black-start decision-making problem with a large group of decision-makers.Group decision-making preferences are obtained by clustering analysis,and the final black-start decision-making results are achieved by combining the weights of black-start indexes and the preferences of the decision-making group.The effectiveness of the proposed method is validated by a practical case.This work extends the black-start decision-making problem to situations with a large group of decision-makers.展开更多
Discharge branching is a general phenomenon in atmospheric-pressure air,dense gases,and two-phase mixtures(TPMs).In this work,an ultraviolet imaging device is utilized to investigate the branching of positive pulsed d...Discharge branching is a general phenomenon in atmospheric-pressure air,dense gases,and two-phase mixtures(TPMs).In this work,an ultraviolet imaging device is utilized to investigate the branching of positive pulsed discharges in TPMs.Comparison among the captured images indicates that the branching is caused by the voltages and the macropartilces in the discharge channels combining together.The interaction of macroparticles with ions,electrons or photons is one reason for the branching behavior of pulsed discharges.The generation of electrons at the discharge front closely relates to the work function of dielectric macroparticles,which is a key parameter influencing the electron-emission ability of macroparticle surfaces.The electric field alteration under various applied voltage in TPMs,which is calculated by a two-dimension finite element method,is the other reason for the guiding effect of macroparticles on the streamers compared with in the air.展开更多
Contaminations adhering on HVDC transmission line will change its corona characteristics to generate electromagnetic pollution. The corona-induced radio interference and audible noise become important factors influenc...Contaminations adhering on HVDC transmission line will change its corona characteristics to generate electromagnetic pollution. The corona-induced radio interference and audible noise become important factors influencing the configuration and costs of transmission project. For understanding the effects of contaminations on the corona pulse characteristics of an HVDC transmission line,a corona cage was adopted to experimentally investigate corona pulse inception voltage and corona pulse characteristics of the conductors with different contaminations on surfaces. The contaminations include simulated contaminations,carbon powder,cement and fine sand. The results show that when conductor is covered with contaminations,the positive polarity corona pulses have high amplitude and low frequency,while the negative polarity corona pulses have low amplitude and incremental high frequency components. The corona pulse inception voltage presents a negatively exponential decrease with the increase of contamination density,showing a saturation trend. Fine sand shows the greatest effect on the corona pulse inception voltage with positive polarity,while cement shows the least effect. A function of corona inception voltage and surface contamination density is given. This study may provide reference for design of transmission lines.展开更多
基金Project supported by National Basic Research Program of China (973 Program) (2011CB209400), National Fligh-tech Research and Developmerit Program of China (863 Program (2011AA040405), National Natural Science Foundation of China (Ul134106), 3551 Optics Valley Personal Plan of Wuhan East Lake High-tech Development Zone, Science and Technology Program of SGCC(SG[2009], SG[2013]).
文摘In recent years,along with the rapid expansion of power grids,the increasing complication of grid structures,and the development of smart grids and energy technologies,the lightning protection of power grids becomes increasingly prominent.Power grids of China have acquired significant achievements on lightning protection technologies,which are reviewed in this paper.A technical route of lightning protection is introduced in detail; it allows us to find problems through detection and measurement of lightning,to analyze problems through evaluation and simulation of lightning,to solve problems through lightning protection measures,and to prevent problems through hazard risk warning of lightning.Following the route,the technical breakthroughs of these four aspects in China are presented,including the chinese lightning detection network(CLDN),natural lightning observations,lightning faults detection at transmission lines,lightning current measurements,progresses in lightning distribution maps,lightning fault replays,lightning hazard risk evaluations,and lightning simulated experiments,as well as novel lightning protection measures.The practical devices and systems corresponding to the technologies mentioned above are also introduced and discussed.Due to the progress of lightning protection technologies in recent years,despite the rapidly growing length of transmission lines in China,the lightning accident rate is controlled at a certain level.
基金Project Supported by Key Technology Research Programof SGCC(SGSC[2005]115)
文摘In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calculated with finite element method for field simulation.Tests on artificial pollution insulators are conducted to study the 50% withstand voltage U50 of artificial pollution suspension insulators under different NSDD(non-soluble deposit density)and asymmetric pollution on the top/bottom surface,and study the change of leakage current with air humidity under different voltage and different ESDD(equivalent salt deposit density).The result shows that asymmetric top/bottom surface pollution has a greater impact on the insulator electrical field distribution,and the leakage current will jump under low air humidity,if had large ESDD,which has practical meanings to the anti-pollution design of the transmission line under different pollution levels across the country.
基金supported by Research Project of Science and Technology from Shenzhen Government of China(No.JC200903180528A)
文摘The impacts of large-scale grid-connected wind farm on direct-driven permanent magnet synchronous generator(PMSG)type are discussed on the small signal stability performances of power systems.Firstly,a simplified practical model of wind farm of PMSG type is derived for analyzing small signal stability.The rotor-fluxoriented control strategy is applied to the modelling of PMSG.Secondly,the framework of small signal stability analysis incorporating wind farm of PMSG type is built.Finally,the different simulation scenarios based on the IEEE 3-generator-9-bus test system as benchmark are designed to conduct the eigenvalue analysis and to assess the impacts of wind farm of PMSG type on power system small signal stability.Some conclusions are drawn with simulation results.
基金supported by National Natural Science Foundation of China(No.51177019,61074100,60974036)Doctoral Fund of Ministry of Education of China(No.20090092110020)and the State Grid Corporation of China
文摘Besides common characteristics of wind power,there are some special characteristics in China power system,including large-scale,long distance transmission and lack of flexible regulating power sources.These special characteristics make power dispatch more challenging in China.Many studies have been carried out and some improvements are presented including wind power monitoring and control as well as evaluation of wind power integration capabilities.As a demonstration project,the technologies are integrated into the energy management system and are implemented in the Northwest China power system.They provide effective measures for wind power dispatch in the grid.
文摘The dynamic transmission characteristics and the sensitivities of the three stage idler gear system of the new NC power turret are studied in the paper. Considering the strongly nonlinear factors such as the periodically time-varying mesh stiffness, the nonlinear tooth backlash, the lump-parameter model of the gear system is developed with one rotational and two translational freedoms of each gear. The eigen-values and eigenvectors are derived and analyzed on the basis of the real modal theory. The sensitivities of natural frequencies to design parameters including supporting and meshing stiffnesses, gear masses, and moments of inertia by the direct differential method are also calculated. The results show the quantitative and qualitative impact of the parameters to the natural characteristics of the gear system. Furthermore, the periodic steady state solutions are obtained by the numerical approach based on the nonlinear model. These results are employed to gain insights into the primary controlling parameters, to forecast the severity of the dynamic response, and to assess the acceptability of the gear design.
基金This work was supported by the National Key Research and Development Program of China(2022YFC3003101)the Fundamental Research Funds for the Central Universities(WK2320000050)the Science and Technology Program of State Grid Anhui Electric Power Co.,Ltd.(521205220001).
文摘Forest fire accidents caused by distribution line faults occur frequently,resulting in heavy impacts on people’s safety and social and economic development.Currently,there are few risk assessments for forest fires induced by over-head distribution lines,and existing assessment methods may have difficulties in data acquisition.On this basis,a novel as-sessment framework based on an analytic hierarchy process,a Bayesian network and a Fussel-Vesely importance metric is proposed in this paper.The framework combines field research and historical operation and maintenance data to assess the regional-scale risk of forest fires induced by overhead distribution lines to derive the probability of forest fires and to identify high-risk lines and key hazard events in the assessment region.Finally,taking the southern Anhui region as an ex-ample,the annual fire probability of forest fires induced by overhead distribution lines in the southern Anhui region is 5.88%,and rectification measures are proposed.This study provides management with a complete assessment framework that optimizes the difficulty of data collection and allows for additional targeted corrective measures to be proposed for the entire region and route on the basis of the assessment results.
文摘It is one of the most effective ways to use laboratory long air gap discharges for investigating the fundamental process involved in the lightning strike.During the 1960s and the 1970s,the electro-geometrical method(EGM)and the rolling sphere method were developed base on the breakdowncharacteristics of negative long spark discharges,which have been widely used to design the lightning shielding system of transmission lines and structures.In recent years,the scale of the power facilities is increased dramatically with the rising of power grid's voltage level.The impact of upward connecting leader launched from those large-scale facilities on the lightning shielding performance cannot be neglected;otherwise,the validity of the EGM in the lightning shielding design of EHV and UHV transmission lines will be challenged.The research evolutions on the lightning striking distance,the lightning simulation experiments and the positive upward connecting leader process by using laboratory long sparks are reviewed and discussed in this paper.
基金Project supported by National Basic Research Program of China(973 Program) (2011CB 209400)Program of State Key Laboratory of Power Systems for ±1 100 kV UHVDC Technology(SKLD10M09)
文摘The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.
基金supported by the National Natural Science Foundation of China(6110418661273076)
文摘The stochastic convergence of the cubature Kalmanfilter with intermittent observations (CKFI) for general nonlinearstochastic systems is investigated. The Bernoulli distributed ran-dom variable is employed to describe the phenomenon of intermit-tent observations. According to the cubature sample principle, theestimation error and the error covariance matrix (ECM) of CKFIare derived by Taylor series expansion, respectively. Afterwards, itis theoretically proved that the ECM will be bounded if the obser-vation arrival probability exceeds a critical minimum observationarrival probability. Meanwhile, under proper assumption corre-sponding with real engineering situations, the stochastic stabilityof the estimation error can be guaranteed when the initial estima-tion error and the stochastic noise terms are sufficiently small. Thetheoretical conclusions are verified by numerical simulations fortwo illustrative examples; also by evaluating the tracking perfor-mance of the optical-electric target tracking system implementedby CKFI and unscented Kalman filter with intermittent observa-tions (UKFI) separately, it is demonstrated that the proposed CKFIslightly outperforms the UKFI with respect to tracking accuracy aswell as real time performance.
基金Project supported by National Basic Research Program of China (973 Program) (2011CB 209400)State Key Laboratory of Control and Simulation of Power Systems and Generation Equipments (SKLD10M09)Program for ±1 100 kV UHVDC Technology
文摘Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.
基金Project(2017YFB0903300)supported by National Key R&D Program of ChinaProject(2016M601593)supported by China Postdoctoral Science Foundation
文摘Saturator is one of the core components of humid air turbine (HAT) and is the main feature of HAT making it different from other gas turbine cycles. Due to the lack of sufficient experience in commercial plant operation, HAT cycle has a great demand for modeling and simulation of the system and its components, especially the saturator, to provide reference for system design and optimization. The conventional saturator models are usually based on the theory of heat and mass transfer, which need two accurate coefficients to ensure convincing results. This work proposes a global heat and mass transfer coefficient based on cooling tower technology to model the saturator in small-scale HAT cycle. Compared with the experimental data, the simulation results show that the proposed model well predicts the dynamic humidity and temperature distribution characteristics of saturator at low air pressure and temperature.
基金Project(2017YFB0903300)supported by the National Key R&D Program of ChinaProject(2016M601593)supported by the China Postdoctoral Science Foundation
文摘Due to the fact that the turbine outlet temperature of aeroderivative three-shaft gas turbine is low,the conventional combined cycle is not suitable for three-shaft gas turbines.However,the humid air turbine(HAT)cycle provides a new choice for aeroderivative gas turbine because the humidification process does not require high temperature.Existing HAT cycle plants are all based on single-shaft gas turbines due to their simple structures,therefore converting aeroderivative three-shaft gas turbine into HAT cycle still lacks sufficient research.This paper proposes a HAT cycle model on a basis of an aeroderivative three-shaft gas turbine.Detailed HAT cycle modelling of saturator,gas turbine and heat exchanger are carried out based on the modular modeling method.The models are verified by simulations on the aeroderivative three-shaft gas turbine.Simulation results show that the studied gas turbine with original size and characteristics could not reach the original turbine inlet temperature because of the introduction of water.However,the efficiency still increases by 0.16%when the HAT cycle runs at the designed power of the simple cycle.Furthermore,simulations considering turbine modifications show that the efficiency could be significantly improved.The results obtained in the paper can provide reference for design and analysis of HAT cycle based on multi-shaft gas turbine especially the aeroderivative gas turbine.
基金supported by the National Natural Science Foundation of China(Grant No.51874041)the National Outstanding Youth Science Fund Project of National Natural Science Foundation of China(Grant No.52202012)。
文摘High-speed impact threats and terrorist actions on the battlefield require the development of more effective protective materials and structures,and various protective structure is designed according their energy-absorbing characteristics.In this research,the deformation behavior,microscopic failure modes and energy absorption characteristics of re-entrant hexagonal structure,regular hexagonal structure and regular quadrilateral structure are studied under different strain rates impact.The re-entrant hexagonal structure forms a“X”-shaped deformation zone,the regular quadrilateral and regular hexagonal structure form an“I”-shaped deformation zone.The microscopic appearance of the section is a mixed fracture form.The effects of the topological shape,cell angle,and cell height on the impact behavior of the structure were evaluated.When the cell height is fixed and the cell angle is changed,the energy absorption of the structure increase and then decrease as the relative density increase.The mechanical properties of the structure are optimal when the relative density is about 18.6%and the cell angle is22.5°.When the cell angle is fixed and the cell height is changed,as the relative density increases,the energy absorption of the structure gradually increases.The regular quadrilateral structure and the reentrant hexagonal structure experienced clear strain rate effects under dynamic impact conditions;the regular hexagonal structure did not exhibit obvious strain rate effects.The results presented herein provide a basis for further rational design and selection of shock-resistant protective structures that perform well in high-speed impact environments.
基金Project supported by National Natural Science Foundation of China (51077101, 51277133), National Basic Research Program of China (973 Program) (2009CB 724505).
文摘The space charge behavior of a dielectric under HVDC is influenced by the charge trap energy distribution in it. Hence, we in- vestigated the charge trap distributions in several kinds of typical polymer materials using thermally stimulated discharge (TSD) and photo-stimulated discharge (PSD) methods, respectively. The experimental results show that,there is a significant difference between the trap energy distributions obtained by the two methods, but the difference decreases with the increase of the melting point of polymers. This is attributed to the change of the trap center environment during TSD caused by the increasing movements of both main chains and branched chains in polymers. PSD method is more accurate for investigating charge trap distribution in dielectrics, especially for polymers with low melting points.
基金supported by National Natural Science Foundation of China (No.51007080)National High Technology Research and Development Program of China (863 Program) (No.2011AA05A105)+1 种基金the Fundamental Research Funds for the Central Universities (No.2012QNA4011)key project from Zhejiang Electric Power Corporation
文摘The optimization of black-start decision-making plays an important role in the rapid restoration of a power system after a major failure/outage.With the introduction of the concept of smart grids and the development of real-time communication networks,the black-start decision-makers are no longer limited to only one or a few power system experts such as dispatchers,but rather a large group of professional people in practice.The overall behaviors of a large decision-making group of decision-makers/experts are more complicated and unpredictable.However,the existing methods for black-start decision-making cannot handle the situations with a large group of decision-makers.Given this background,a clustering algorithm is presented to optimize the black-start decision-making problem with a large group of decision-makers.Group decision-making preferences are obtained by clustering analysis,and the final black-start decision-making results are achieved by combining the weights of black-start indexes and the preferences of the decision-making group.The effectiveness of the proposed method is validated by a practical case.This work extends the black-start decision-making problem to situations with a large group of decision-makers.
基金Project supported by National Natural Science Foundation of China(50237010),National Basic Research Program of China(973 Program)(2011CB209400)
文摘Discharge branching is a general phenomenon in atmospheric-pressure air,dense gases,and two-phase mixtures(TPMs).In this work,an ultraviolet imaging device is utilized to investigate the branching of positive pulsed discharges in TPMs.Comparison among the captured images indicates that the branching is caused by the voltages and the macropartilces in the discharge channels combining together.The interaction of macroparticles with ions,electrons or photons is one reason for the branching behavior of pulsed discharges.The generation of electrons at the discharge front closely relates to the work function of dielectric macroparticles,which is a key parameter influencing the electron-emission ability of macroparticle surfaces.The electric field alteration under various applied voltage in TPMs,which is calculated by a two-dimension finite element method,is the other reason for the guiding effect of macroparticles on the streamers compared with in the air.
基金Project Supported by Science and Technology Foundation of State Grid Corporation of China(SGSC[2005]81)
文摘Contaminations adhering on HVDC transmission line will change its corona characteristics to generate electromagnetic pollution. The corona-induced radio interference and audible noise become important factors influencing the configuration and costs of transmission project. For understanding the effects of contaminations on the corona pulse characteristics of an HVDC transmission line,a corona cage was adopted to experimentally investigate corona pulse inception voltage and corona pulse characteristics of the conductors with different contaminations on surfaces. The contaminations include simulated contaminations,carbon powder,cement and fine sand. The results show that when conductor is covered with contaminations,the positive polarity corona pulses have high amplitude and low frequency,while the negative polarity corona pulses have low amplitude and incremental high frequency components. The corona pulse inception voltage presents a negatively exponential decrease with the increase of contamination density,showing a saturation trend. Fine sand shows the greatest effect on the corona pulse inception voltage with positive polarity,while cement shows the least effect. A function of corona inception voltage and surface contamination density is given. This study may provide reference for design of transmission lines.