The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on...The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on analyzing the existing TEF sensors and the measurement principle of ion-current density,the influence from ions on TEF measurements is quantitively studied.The results show that the ions generated by the corona from a HVDC transmission line in operation cause errors in the measurement of TEF.This error is determined through analyzing the component of total measuring current on the filed mill's sensing electrode: if no appropriate approach taken,the maximum measurement error reaches up to 4.3%.Furthermore,a method that can eliminate such error,and hence improve the accuracy of TEF sensors is designed.展开更多
A long-standing mystery in the study of Field-Aligned Currents(FACs) has been that: how the currents are generated and why they appear to be much stronger at high altitudes than in the ionosphere. Here we present two ...A long-standing mystery in the study of Field-Aligned Currents(FACs) has been that: how the currents are generated and why they appear to be much stronger at high altitudes than in the ionosphere. Here we present two events of magnetotail FACs observed by the Magnetospheric Multiscale Spacecraft(MMS) on 1 st July and 14 th July 2016, to show how the Substorm Current Wedges(SCW) were formed. The results show that particles were transferred heading towards the Earth during the expansion phase of substorms.The azimuthal flow formed clockwise(counter-clockwise) vortex-like motion, and then generated downward(upward) FACs on the tailward/poleward side of the distorted field with opposite vorticity on their Earthward/equatorward side. We also analyzed the Region 1 FACs observed by the Earth Explorer Swarm spacecraft on 1 st July 2016 and found that they were associated with FACs observed by MMS, although differing by a factor of 10. This difference suggests that either there was the closure of the currents at altitudes above 500 km or the currents were not strictly parallel to B and closed at longitudes away from where they were generated.展开更多
The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling syst...The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling system is implemented. The mathematic model is established for thermal current field computation, simulation and analysis in the powertrain cabin. The three-dimensional structure of the powertrain cabin is optimized. The validity of the cooling system design is proved. The foundation for optimizing the whole electric transmission system configuration is laid.展开更多
An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so deta...An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.展开更多
In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calcu...In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calculated with finite element method for field simulation.Tests on artificial pollution insulators are conducted to study the 50% withstand voltage U50 of artificial pollution suspension insulators under different NSDD(non-soluble deposit density)and asymmetric pollution on the top/bottom surface,and study the change of leakage current with air humidity under different voltage and different ESDD(equivalent salt deposit density).The result shows that asymmetric top/bottom surface pollution has a greater impact on the insulator electrical field distribution,and the leakage current will jump under low air humidity,if had large ESDD,which has practical meanings to the anti-pollution design of the transmission line under different pollution levels across the country.展开更多
There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cab...There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cable simultaneously, a double differential-mode current in- jection test method (DDMCI) is proposed. The method adopted the equivalence source wave theorem and Baum-Liu-Tesche(BLT) equation as its theory foundation. The equivalent corresponding relation between injection voltage and radiation electric field intensity is derived, and the phase relation between the two injection voltage sources is confirmed. The results indicate that the amplitude and phase of the equivalent injection voltage source is closely related to the S parameter of directional coupling device, the transmission line length, and the source vector in BLT equation, but has nothing to do with the reflection coefficient between the two equipment pieces. Therefore, by choosing the right amplitude and phase of the double injection voltage sources, the DDMCI test is equivalent to the radiation test for two interconnected equipment of a system.展开更多
Investigations are reported into the use of an electromagnetically convoluted arc,external to a magnetic field(B-field)producing coil,in combination with a parallel R,L,C resonant circuit for interrupting quasi-steady...Investigations are reported into the use of an electromagnetically convoluted arc,external to a magnetic field(B-field)producing coil,in combination with a parallel R,L,C resonant circuit for interrupting quasi-steady currents.In order to elucidate the complex interactions between the arc,B-field and R,L,C circuit,the B-field producing coil is energised independently from the current to be interrupted and the R,L,C circuit.Experimental results are presented for the time variation of the currents flowing through the arc gap,the B-field coil and the parallel R,L,C circuit,along with the voltage across the arc gap.An insight is gained into the role of various effects,which are produced by the complex interactions and which might be used to advantage for direct current interruption.展开更多
本文研究了2000年10月5日磁暴主相两个不同时段期间环电流的变化速度与相应太阳风参数的关系.研究发现,磁暴主相期间环电流的变化速度并不取决于行星际磁场南向分量的平均值和最大值,也不取决于太阳风电场的平均值和最大值.本文的研究证...本文研究了2000年10月5日磁暴主相两个不同时段期间环电流的变化速度与相应太阳风参数的关系.研究发现,磁暴主相期间环电流的变化速度并不取决于行星际磁场南向分量的平均值和最大值,也不取决于太阳风电场的平均值和最大值.本文的研究证明,磁暴环电流增强期间环电流的变化速度,不仅取决于行星际磁场南向分量和太阳风的速度,还取决于太阳风的动压,而且太阳风的动压起着非常重要的作用.研究还发现,采用Burton et al.(1975)方程和O′Brien,McPherron (2000a)方程估算得到的2000年10月5日的两次地磁活动的强度远低于实际的观测值.展开更多
基金Project supported by National Natural Science Foundation of China (61273165 51207005).
文摘The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on analyzing the existing TEF sensors and the measurement principle of ion-current density,the influence from ions on TEF measurements is quantitively studied.The results show that the ions generated by the corona from a HVDC transmission line in operation cause errors in the measurement of TEF.This error is determined through analyzing the component of total measuring current on the filed mill's sensing electrode: if no appropriate approach taken,the maximum measurement error reaches up to 4.3%.Furthermore,a method that can eliminate such error,and hence improve the accuracy of TEF sensors is designed.
基金Supported by National Natural Science Foundation of China(41874190,41231066)
文摘A long-standing mystery in the study of Field-Aligned Currents(FACs) has been that: how the currents are generated and why they appear to be much stronger at high altitudes than in the ionosphere. Here we present two events of magnetotail FACs observed by the Magnetospheric Multiscale Spacecraft(MMS) on 1 st July and 14 th July 2016, to show how the Substorm Current Wedges(SCW) were formed. The results show that particles were transferred heading towards the Earth during the expansion phase of substorms.The azimuthal flow formed clockwise(counter-clockwise) vortex-like motion, and then generated downward(upward) FACs on the tailward/poleward side of the distorted field with opposite vorticity on their Earthward/equatorward side. We also analyzed the Region 1 FACs observed by the Earth Explorer Swarm spacecraft on 1 st July 2016 and found that they were associated with FACs observed by MMS, although differing by a factor of 10. This difference suggests that either there was the closure of the currents at altitudes above 500 km or the currents were not strictly parallel to B and closed at longitudes away from where they were generated.
文摘The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling system is implemented. The mathematic model is established for thermal current field computation, simulation and analysis in the powertrain cabin. The three-dimensional structure of the powertrain cabin is optimized. The validity of the cooling system design is proved. The foundation for optimizing the whole electric transmission system configuration is laid.
基金Project Supported by China11th Five-year National Key Technologies R&D Program(2006BAA02A20)
文摘An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.
基金Project Supported by Key Technology Research Programof SGCC(SGSC[2005]115)
文摘In this paper,the electrical fields along the insulator surface under different scenarios,such as asymmetric pollution on top/bottom surface,and uneven circumferential distribution of surface pollution,have been calculated with finite element method for field simulation.Tests on artificial pollution insulators are conducted to study the 50% withstand voltage U50 of artificial pollution suspension insulators under different NSDD(non-soluble deposit density)and asymmetric pollution on the top/bottom surface,and study the change of leakage current with air humidity under different voltage and different ESDD(equivalent salt deposit density).The result shows that asymmetric top/bottom surface pollution has a greater impact on the insulator electrical field distribution,and the leakage current will jump under low air humidity,if had large ESDD,which has practical meanings to the anti-pollution design of the transmission line under different pollution levels across the country.
基金Project supported by Arm Pre-research Program (51333040101), National Defense 973 Program (6131380301 ), National Natural Science Foundation of China (61040003).
文摘There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cable simultaneously, a double differential-mode current in- jection test method (DDMCI) is proposed. The method adopted the equivalence source wave theorem and Baum-Liu-Tesche(BLT) equation as its theory foundation. The equivalent corresponding relation between injection voltage and radiation electric field intensity is derived, and the phase relation between the two injection voltage sources is confirmed. The results indicate that the amplitude and phase of the equivalent injection voltage source is closely related to the S parameter of directional coupling device, the transmission line length, and the source vector in BLT equation, but has nothing to do with the reflection coefficient between the two equipment pieces. Therefore, by choosing the right amplitude and phase of the double injection voltage sources, the DDMCI test is equivalent to the radiation test for two interconnected equipment of a system.
文摘Investigations are reported into the use of an electromagnetically convoluted arc,external to a magnetic field(B-field)producing coil,in combination with a parallel R,L,C resonant circuit for interrupting quasi-steady currents.In order to elucidate the complex interactions between the arc,B-field and R,L,C circuit,the B-field producing coil is energised independently from the current to be interrupted and the R,L,C circuit.Experimental results are presented for the time variation of the currents flowing through the arc gap,the B-field coil and the parallel R,L,C circuit,along with the voltage across the arc gap.An insight is gained into the role of various effects,which are produced by the complex interactions and which might be used to advantage for direct current interruption.
文摘本文研究了2000年10月5日磁暴主相两个不同时段期间环电流的变化速度与相应太阳风参数的关系.研究发现,磁暴主相期间环电流的变化速度并不取决于行星际磁场南向分量的平均值和最大值,也不取决于太阳风电场的平均值和最大值.本文的研究证明,磁暴环电流增强期间环电流的变化速度,不仅取决于行星际磁场南向分量和太阳风的速度,还取决于太阳风的动压,而且太阳风的动压起着非常重要的作用.研究还发现,采用Burton et al.(1975)方程和O′Brien,McPherron (2000a)方程估算得到的2000年10月5日的两次地磁活动的强度远低于实际的观测值.