Diffracted seismic waves may be used to help identify and track geologically heterogeneous bodies or zones.However,the energy of diffracted waves is weaker than that of reflections.Therefore,the extraction of diffract...Diffracted seismic waves may be used to help identify and track geologically heterogeneous bodies or zones.However,the energy of diffracted waves is weaker than that of reflections.Therefore,the extraction of diffracted waves is the basis for the effective utilization of diffracted waves.Based on the difference in travel times between diffracted and reflected waves,we developed a method for separating the diffracted waves via singular value decomposition filters and presented an effective processing flowchart for diffracted wave separation and imaging.The research results show that the horizontally coherent difference between the reflected and diffracted waves can be further improved using normal move-out(NMO) correction.Then,a band-rank or high-rank approximation is used to suppress the reflected waves with better transverse coherence.Following,separation of reflected and diffracted waves is achieved after the filtered data are transformed into the original data domain by inverse NMO.Synthetic and field examples show that our proposed method has the advantages of fewer constraints,fast processing speed and complete extraction of diffracted waves.And the diffracted wave imaging results can effectively improve the identification accuracy of geological heterogeneous bodies or zones.展开更多
Ultrasonic Lamb waves are considered as a sensitive and effective tool for nondestructive testing and evaluation of plate-like or pipe-like structures. The nature of multimode and dispersion causes the wave packets to...Ultrasonic Lamb waves are considered as a sensitive and effective tool for nondestructive testing and evaluation of plate-like or pipe-like structures. The nature of multimode and dispersion causes the wave packets to spread, and the modes overlap in both time and frequency domains as they propagate through the structures. By using a two-component laser interferometer technique, in combination with a priori knowledge of the dispersion characteristics and wave structure information of Lamb wave modes, a two-component signal processing technique is presented for implementing dispersion removal and mode separation simultaneously for two modes mixture signals of Lamb waves. The proposed algorithm is first processed and verified using synthetic Lamb wave signals. Then, the two-component displacements test experiment is conducted using different aluminum plate samples. Moreover, we confirm the effectiveness and robustness of this method.展开更多
Transcranial focused ultrasound is a booming noninvasive therapy for brain stimuli. The Kelvin–Voigt equations are employed to calculate the sound field created by focusing a 256-element planar phased array through a...Transcranial focused ultrasound is a booming noninvasive therapy for brain stimuli. The Kelvin–Voigt equations are employed to calculate the sound field created by focusing a 256-element planar phased array through a monkey skull with the time-reversal method. Mode conversions between compressional and shear waves exist in the skull. Therefore, the wave field separation method is introduced to calculate the contributions of the two waves to the acoustic intensity and the heat source, respectively. The Pennes equation is used to depict the temperature field induced by ultrasound. Five computational models with the same incident angle of 0?and different distances from the focus for the skull and three computational models at different incident angles and the same distance from the focus for the skull are studied. Numerical results indicate that for all computational models, the acoustic intensity at the focus with mode conversions is 12.05%less than that without mode conversions on average. For the temperature rise, this percentage is 12.02%. Besides, an underestimation of both the acoustic intensity and the temperature rise in the skull tends to occur if mode conversions are ignored. However, if the incident angle exceeds 30?, the rules of the over-and under-estimation may be reversed. Moreover,shear waves contribute 20.54% of the acoustic intensity and 20.74% of the temperature rise in the skull on average for all computational models. The percentage of the temperature rise in the skull from shear waves declines with the increase of the duration of the ultrasound.展开更多
基金supported by the National Natural Science Foundation of China(41874123)Shaanxi Province Natural Science Basic Research Project(2017JZ007)PetroChina Innovation Foundation(2014D-5006-0303)。
文摘Diffracted seismic waves may be used to help identify and track geologically heterogeneous bodies or zones.However,the energy of diffracted waves is weaker than that of reflections.Therefore,the extraction of diffracted waves is the basis for the effective utilization of diffracted waves.Based on the difference in travel times between diffracted and reflected waves,we developed a method for separating the diffracted waves via singular value decomposition filters and presented an effective processing flowchart for diffracted wave separation and imaging.The research results show that the horizontally coherent difference between the reflected and diffracted waves can be further improved using normal move-out(NMO) correction.Then,a band-rank or high-rank approximation is used to suppress the reflected waves with better transverse coherence.Following,separation of reflected and diffracted waves is achieved after the filtered data are transformed into the original data domain by inverse NMO.Synthetic and field examples show that our proposed method has the advantages of fewer constraints,fast processing speed and complete extraction of diffracted waves.And the diffracted wave imaging results can effectively improve the identification accuracy of geological heterogeneous bodies or zones.
基金Project supported by the National Natural Science Foundation of China(Grant No.11374230)
文摘Ultrasonic Lamb waves are considered as a sensitive and effective tool for nondestructive testing and evaluation of plate-like or pipe-like structures. The nature of multimode and dispersion causes the wave packets to spread, and the modes overlap in both time and frequency domains as they propagate through the structures. By using a two-component laser interferometer technique, in combination with a priori knowledge of the dispersion characteristics and wave structure information of Lamb wave modes, a two-component signal processing technique is presented for implementing dispersion removal and mode separation simultaneously for two modes mixture signals of Lamb waves. The proposed algorithm is first processed and verified using synthetic Lamb wave signals. Then, the two-component displacements test experiment is conducted using different aluminum plate samples. Moreover, we confirm the effectiveness and robustness of this method.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.81527901,11604361,and 91630309)
文摘Transcranial focused ultrasound is a booming noninvasive therapy for brain stimuli. The Kelvin–Voigt equations are employed to calculate the sound field created by focusing a 256-element planar phased array through a monkey skull with the time-reversal method. Mode conversions between compressional and shear waves exist in the skull. Therefore, the wave field separation method is introduced to calculate the contributions of the two waves to the acoustic intensity and the heat source, respectively. The Pennes equation is used to depict the temperature field induced by ultrasound. Five computational models with the same incident angle of 0?and different distances from the focus for the skull and three computational models at different incident angles and the same distance from the focus for the skull are studied. Numerical results indicate that for all computational models, the acoustic intensity at the focus with mode conversions is 12.05%less than that without mode conversions on average. For the temperature rise, this percentage is 12.02%. Besides, an underestimation of both the acoustic intensity and the temperature rise in the skull tends to occur if mode conversions are ignored. However, if the incident angle exceeds 30?, the rules of the over-and under-estimation may be reversed. Moreover,shear waves contribute 20.54% of the acoustic intensity and 20.74% of the temperature rise in the skull on average for all computational models. The percentage of the temperature rise in the skull from shear waves declines with the increase of the duration of the ultrasound.