期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Dynamic test on waste heat recovery system with organic Rankine cycle 被引量:3
1
作者 王志奇 刘力文 +1 位作者 夏小霞 周乃君 《Journal of Central South University》 SCIE EI CAS 2014年第12期4607-4612,共6页
Dynamic performance is important to the controlling and monitoring of the organic Rankine cycle(ORC) system so to avoid the occurrence of unwanted conditions. A small scale waste heat recovery system with organic Rank... Dynamic performance is important to the controlling and monitoring of the organic Rankine cycle(ORC) system so to avoid the occurrence of unwanted conditions. A small scale waste heat recovery system with organic Rankine cycle was constructed and the dynamic behavior was presented. In the dynamic test, the pump was stopped and then started. In addition, there was a step change of the flue gas volume flow rate and the converter frequency of multistage pump, respectively. The results indicate that the working fluid flow rate has the shortest response time, followed by the expander inlet pressure and the expander inlet temperature.The operation frequency of pump is a key parameter for the ORC system. Due to a step change of pump frequency(39.49-35.24 Hz),the expander efficiency and thermal efficiency drop by 16% and 21% within 2 min, respectively. Besides, the saturated mixture can lead to an increase of the expander rotation speed. 展开更多
关键词 organic Rankine cycle waste heat recovery dynamic performance
在线阅读 下载PDF
Waste heat water pumping model with direct contact cooling
2
作者 Kittiwoot Sutthivirode Naris Pratinthong +2 位作者 Pichai Namprakai Natthaphon Roonprasang Taveewat Suparos 《Journal of Central South University》 SCIE EI CAS 2014年第10期3896-3910,共15页
The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for u... The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for underground water. In this model, a heater installed within the heat tank represented sources of waste heat as energy input for finding appropriate conditions of the 10 L pump model. The system operation had five stages: heating, pumping, vapor flow, cooling, and water suction. The overall water heads of 3, 4.5, 6 and 7.5 m were tested. At the same time, it was found that the pump with 50% air volume is sufficient for pumping water to a desired level. In the experiment, the temperatures in the heating and pumping stages were 100-103 ℃and 80-90 ℃, respectively. The pressure in the pumping stage was 12-18 kPa, and the pressure in the suction stage was about-80 kPa, sufficient for the best performance. It could pump 170 L of water at a 2 m suction head, 120 L at a 3.5 m suction head, 100 L at a 5 m suction head, and 65 L at a 6.5 m suction head in 2 h. A mathematical model for larger pumps was also presented, which operates nearly the same as the present system. Economic analysis of the 10 L pump was also included. 展开更多
关键词 direct contact cooling driving tank steam-air power liquid piston waste heat
在线阅读 下载PDF
Efficiency analysis of trilateral-cycle power systems for waste heat recovery-to-power generation
3
作者 Habeeb A.AJIMOTOKAN 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第12期3160-3170,共11页
Numerous innovative heat recovery-to-power technologies have been resourcefully and technologically exploited to bridge the growing gap between energy needs and its sustainable and affordable supply.Among them,the pro... Numerous innovative heat recovery-to-power technologies have been resourcefully and technologically exploited to bridge the growing gap between energy needs and its sustainable and affordable supply.Among them,the proposed trilateral-cycle(TLC) power system exhibits high thermodynamic efficiency during heat recovery-to-power from low-to-medium temperature heat sources.The TLCs are proposed and analysed using n-pentane as working fluid for waste heat recovery-to-power generation from low-grade heat source to evaluate the thermodynamic efficiency of the cycles.Four different single stage TLC configurations with distinct working principles are modelled thermodynamically using engineering equation solver.Based on the thermodynamic framework,thermodynamic performance simulation and efficiency analysis of the cycles as well as the exergy efficiencies of the heating and condensing processes are carried out and compared in their efficiency.The results show that the simple TLC,recuperated TLC,reheat TLC and regenerative TLC operating at subcritical conditions with cycle high temperature of 473 K can attain thermal efficiencies of 21.97%,23.91%,22.07% and 22.9%,respectively.The recuperated TLC attains the highest thermodynamic efficiency at the cycle high temperature because of its lowest exergy destruction rates in the heat exchanger and condenser.The efficiency analysis carried out would assist in guiding thermodynamic process development and thermal integration of the proposed cycles. 展开更多
关键词 trilateral cycle waste heat recovery-to-power generation thermodynamic performance simulation efficiency analysis process development and integration
在线阅读 下载PDF
Deep Utilization of Exhaust Heat and Comprehensive Optimization of Tail Heating Surfaces for Utility Boilers
4
作者 Xu Gang XU Cheng +2 位作者 YANG Yongping HUANG Shengwei ZHANG Kai 《中国电机工程学报》 EI CSCD 北大核心 2013年第14期I0001-I0016,共16页
In common,the waste heat of the flue gas is recovered and utilized to heat the low temperature feedwater by installing the low temperature economizer(LTE),which can save the steam extracted from the steam turbine and ... In common,the waste heat of the flue gas is recovered and utilized to heat the low temperature feedwater by installing the low temperature economizer(LTE),which can save the steam extracted from the steam turbine and then increase the unit output.However,restricted by the low temperature of waste flue gas,the energy-saving efect is inconspicuous.Based on the common waste heat utilization system of the flue gas. 展开更多
关键词 utility boiler tail heating surface comprehensive optimization waste heat recovery low temperature economizer
在线阅读 下载PDF
Effects of working parameters on gasoline engine exergy balance 被引量:9
5
作者 LIU Jing-ping FU Jian-qin +1 位作者 FENG Ren-hua ZHU Guo-hui 《Journal of Central South University》 SCIE EI CAS 2013年第7期1938-1946,共9页
To improve the energy utilization efficiency of internal combustion (IC) engine, exergy analysis was conducted on a passenger car gasoline engine. According to the thermodynamic theory of IC engine, in-cylinder exer... To improve the energy utilization efficiency of internal combustion (IC) engine, exergy analysis was conducted on a passenger car gasoline engine. According to the thermodynamic theory of IC engine, in-cylinder exergy balance model was built. The working processes of gasoline engine were simulated by using the GT-power. In this way, the required parameters were calculated and then gasoline engine exergy balance was obtained by programming on computer. On this basis, the influences of various parameters on exergy balance were analyzed. Results show that, the proportions of various forms of exergy in gasoline engine from high to low are irreversible loss, effective work, exhaust gas exergy and heat transfer exergy. Effective exergy proportion fluctuates with cylinder volumetric efficiency at full load, while it always increases with break mean effective pressure (BMEP) at part load. Exhaust gas exergy proportion is more sensitive to speed, and it increases with speed increasing except at the highest speed. The lower proportion of heat transfer exergy appears at high speed and high load. Irreversible loss is mainly influenced by load. At part load, higher BMEP results in lower proportion of irreversible loss; at full load, the proportion of irreversible loss changes little except at the highest speed. 展开更多
关键词 gasoline engine exergy balance waste heat recovery thermal efficiency energy conservation
在线阅读 下载PDF
Performance comparison and analysis of a combined power and cooling system based on organic Rankine cycle 被引量:2
6
作者 王志奇 周奇遇 +2 位作者 夏小霞 刘斌 张欣 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第2期353-359,共7页
A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the po... A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the power and refrigeration cycle, respectively. A performance comparison and analysis for the combined system was presented. The results show that dual-pressure ORC-VCRC system can achieve an increase of 7.1% in thermal efficiency and 6.7% in exergy efficiency than that of basic ORC-VCRC. Intermediate pressure is a key parameter to both net power and exergy efficiency of dual-pressure ORC-VCRC system. Combined system can produce maximum net power and exergy efficiency at 0.85 MPa for intermediate pressure and 2.4 MPa for high pressure, respectively. However, superheated temperature at expander inlet has little impact on the two indicators. It can achieve higher overall COP, net power and exergy efficiency at smaller difference between condensation temperature and evaporation temperature of VCRC. 展开更多
关键词 dual-pressure organic Rankine cycle vapor compression refrigeration waste heat performance analysis
在线阅读 下载PDF
An approach for IC engine coolant energy recovery based on low-temperature organic Rankine cycle 被引量:1
7
作者 付建勤 刘敬平 +2 位作者 徐政欣 邓帮林 刘琦 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期727-734,共8页
To promote the fuel utilization efficiency of IC engine, an approach was proposed for IC engine coolant energy recovery based on low-temperature organic Rankine cycle(ORC). The ORC system uses IC engine coolant as hea... To promote the fuel utilization efficiency of IC engine, an approach was proposed for IC engine coolant energy recovery based on low-temperature organic Rankine cycle(ORC). The ORC system uses IC engine coolant as heat source, and it is coupled to the IC engine cooling system. After various kinds of organic working media were compared, R124 was selected as the ORC working medium. According to IC engine operating conditions and coolant energy characteristics, the major parameters of ORC system were preliminary designed. Then, the effects of various parameters on cycle performance and recovery potential of coolant energy were analyzed via cycle process calculation. The results indicate that cycle efficiency is mainly influenced by the working pressure of ORC, while the maximum working pressure is limited by IC engine coolant temperature. At the same working pressure, cycle efficiency is hardly affected by both the mass flow rate and temperature of working medium. When the bottom cycle working pressure arrives at the maximum allowable value of 1.6 MPa, the fuel utilization efficiency of IC engine could be improved by 12.1%.All these demonstrate that this low-temperature ORC is a useful energy-saving technology for IC engine. 展开更多
关键词 IC engine waste heat recovery organic Rankine cycle cycle efficiency coolant energy
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部