期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Equilibrium Strategies in M/M/1 Retrial Queues with Variable Service Rate
1
作者 LIU Yuanyuan YAN Zhaozeng YANG Qin 《应用概率统计》 北大核心 2025年第3期448-466,共19页
We consider a single server constant retrial queue,in which a state-dependent service policy is used to control the service rate.Customer arrival follows Poisson process,while service time and retrial time are exponen... We consider a single server constant retrial queue,in which a state-dependent service policy is used to control the service rate.Customer arrival follows Poisson process,while service time and retrial time are exponential distributions.Whenever the server is available,it admits the retrial customers into service based on a first-come first-served rule.The service rate adjusts in real-time based on the retrial queue length.An iterative algorithm is proposed to numerically solve the personal optimal problem in the fully observable scenario.Furthermore,we investigate the impact of parameters on the social optimal threshold.The effectiveness of the results is illustrated by two examples. 展开更多
关键词 variable service rate retrial queues real-time adaptability equilibrium strategies ALGORITHM
在线阅读 下载PDF
Switching variability index based multiple strategy CFAR detector 被引量:5
2
作者 Yang Li Zhenyuan Ji +1 位作者 Bingfei Li Gil Alterovitz 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第4期580-587,共8页
A switching variability index (SVl) constant false alarm rate (CFAR) detector is proposed for improving the detection performance of VI-CFAR detectors in multiple targets backgrounds. When the presence of non-homo... A switching variability index (SVl) constant false alarm rate (CFAR) detector is proposed for improving the detection performance of VI-CFAR detectors in multiple targets backgrounds. When the presence of non-homogeneity in CFAR reference windows is indicated by a VI-CFAR detector, a switching- CFAR detector is introduced to optimize the performance of the VI-CFAR detector in homogeneous, multiple targets and clutter edge backgrounds. The structure and parameters selection method of the SVI-CFAR detector is presented. Comparisons with classic CFAR detectors and recently proposed detectors are also given. Theoretical analysis and simulation results show that SVICFAR detector maintains the good performance of the VI-CFAR detector in homogeneous and clutter edge backgrounds, while greatly improving the capacity of anti-multi targets. 展开更多
关键词 switching variability index constant false alarm rate(SVI-CFAR) adaptive detection complex environment multiple-strategy detection radar target detection.
在线阅读 下载PDF
An EMD based method for detrending RR interval series without resampling
3
作者 曾超 蒋奇云 +1 位作者 陈朝阳 徐敏 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期567-574,共8页
Slow trends in the RR interval(RRI) series should be removed in the preprocessing step to get a reliable result of heart rate variability(HRV) analysis. Re-sampling is required to convert the unevenly sampled RRI seri... Slow trends in the RR interval(RRI) series should be removed in the preprocessing step to get a reliable result of heart rate variability(HRV) analysis. Re-sampling is required to convert the unevenly sampled RRI series into evenly sampled time series when using the widely accepted smoothness priors approach(SPA). Noise is introduced in this process and the information quality is thus compromised. Empirical mode decomposition(EMD) and its variants, were introduced to directly process the unevenly sampled RRI series. Besides, a RR interval model was proposed to fascinate the introduction of standard metrics for the evaluation of the detrending performance. Based on standard metrics including signal-to-noise-ratio in d B(ISNR), mean square error(EMS), and percent root square difference(DPRS), the effectiveness of detrending methods in RR interval analysis were determined. Results demonstrate that complementary ensemble EMD(CEEMD, a variant of EMD) based method has a higher ISNR, a lower EMS and a lower DPRS as well as a better RRI series detrending performance compared with the SPA method, which would in turn lead to a more accurate HRV analysis. 展开更多
关键词 heart rate variability empirical mode decomposition DETRENDING RR interval model
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部