The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ...The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.展开更多
A control strategy of variable speed limits(VSL)was developed to reduce the travel time at freeway recurrent bottleneck areas.The proposed control strategy particularly focused on preventing the capacity drop and incr...A control strategy of variable speed limits(VSL)was developed to reduce the travel time at freeway recurrent bottleneck areas.The proposed control strategy particularly focused on preventing the capacity drop and increasing the discharge flow.A cell transmission model(CTM)was developed to evaluate the effects of the proposed VSL control strategy on the traffic operations.The results show that the total travel time is reduced by 25.5% and the delay is reduced by 56.1%.The average travel speed is increased by 34.3% and the queue length is reduced by 31.0%.The traffic operation is improved by the proposed VSL control strategy.The way to use the proposed VSL control strategy in different types of freeway bottlenecks was also discussed by considering different traffic flow characteristics.It is concluded that the VSL control strategy is effective for merge bottlenecks but is less effective for diverge bottlenecks.展开更多
Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V...Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.展开更多
Fuzzy logic controller adopting unevenly-distributed membership function was presented with the purpose of enhancing performance of the temperature control precision and robustness for the chamber cooling system.Histo...Fuzzy logic controller adopting unevenly-distributed membership function was presented with the purpose of enhancing performance of the temperature control precision and robustness for the chamber cooling system.Histogram equalization and noise detection were performed to modify the evenly-distributed membership functions of error and error change rate into unevenly-distributed membership functions.Then,the experimental results with evenly and unevenly distributed membership functions were compared under the same outside environment conditions.The experimental results show that the steady-state error is reduced around 40% and the noise disturbance is rejected successfully even though noise range is 60% of the control precision range.The control precision is improved by reducing the steady-state error and the robustness is enhanced by rejecting noise disturbance through the fuzzy logic controller with unevenly-distributed membership function.Moreover,the system energy efficiency and lifetime of electronic expansion valve(EEV) installed in chamber cooling system are improved by adopting the unevenly-distributed membership function.展开更多
Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power el...Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow.展开更多
基金Project(G-0805-10156) supported by US Energy Foundation
文摘The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.
基金Project(2012CB725400)supported by the National Key Basic Research Program of ChinaProject(2011AA110303)supported by the National High Technology Research and Development Program of ChinaProject(YBPY1211)supported by the Scientific Research Foundation of the Graduate School of Southeast University,China
文摘A control strategy of variable speed limits(VSL)was developed to reduce the travel time at freeway recurrent bottleneck areas.The proposed control strategy particularly focused on preventing the capacity drop and increasing the discharge flow.A cell transmission model(CTM)was developed to evaluate the effects of the proposed VSL control strategy on the traffic operations.The results show that the total travel time is reduced by 25.5% and the delay is reduced by 56.1%.The average travel speed is increased by 34.3% and the queue length is reduced by 31.0%.The traffic operation is improved by the proposed VSL control strategy.The way to use the proposed VSL control strategy in different types of freeway bottlenecks was also discussed by considering different traffic flow characteristics.It is concluded that the VSL control strategy is effective for merge bottlenecks but is less effective for diverge bottlenecks.
基金the output of a research project (Title: Application of Doubly Fed Asynchronous machine in Pumped Storage Hydropower Plant in Generate Mode, supported by Islamic Azad University South Tehran Branch)
文摘Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.
文摘Fuzzy logic controller adopting unevenly-distributed membership function was presented with the purpose of enhancing performance of the temperature control precision and robustness for the chamber cooling system.Histogram equalization and noise detection were performed to modify the evenly-distributed membership functions of error and error change rate into unevenly-distributed membership functions.Then,the experimental results with evenly and unevenly distributed membership functions were compared under the same outside environment conditions.The experimental results show that the steady-state error is reduced around 40% and the noise disturbance is rejected successfully even though noise range is 60% of the control precision range.The control precision is improved by reducing the steady-state error and the robustness is enhanced by rejecting noise disturbance through the fuzzy logic controller with unevenly-distributed membership function.Moreover,the system energy efficiency and lifetime of electronic expansion valve(EEV) installed in chamber cooling system are improved by adopting the unevenly-distributed membership function.
文摘Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow.