The heat generation behaviors of fatigue crack are deeply investigated under different preload forces combing numerical simulation and experiment.Firstly,a multi-contact simulation model is applied to stimulate the cr...The heat generation behaviors of fatigue crack are deeply investigated under different preload forces combing numerical simulation and experiment.Firstly,a multi-contact simulation model is applied to stimulate the crack surfaces contact and the horn-sample contact under ultrasonic excitation for calculating the temperature fields.Then,the ultrasonic infrared thermography testing and the microscope testing are carried out for the heat generation and the plastic deformation behaviors of crack region under different preload forces.On this basis,an indirect observation method based on dots distribution is proposed to estimate the plastic deformation on crack contact surfaces.The obtained results show that the temperature rise of crack region increases with the increase of preload force when the preload force is less than 250 N,while the temperature rise rapidly declines due to the plastic deformation on crack contact surfaces and the inhibition effect when the preload force is 280 N.Moreover,the plastic deformation does not lead to the crack propagation,but reduces the detection repeatability of fatigue crack.This work provides an effective method for optimizing testing conditions in practical testing processes,which will be helpful to the establishment of testing standards for batches of test objects in ultrasonic infrared thermography testing.展开更多
A 3D temperature field distribution of biological tissue for superficial hyperthermia using a pulse modulated microwave (PMMW) was presented. A 3D sliced homogeneous phantom was radiated by the PMMW and an infrared ...A 3D temperature field distribution of biological tissue for superficial hyperthermia using a pulse modulated microwave (PMMW) was presented. A 3D sliced homogeneous phantom was radiated by the PMMW and an infrared thermal imager was applied to image temperature distribution throughout the phantom. The period of the PMMW is 3 s and the output power is 35 W. The temperature rises by at least 3 ℃ in the phantom when the duty cycle varies from 1/3, 1/2, 2/3 to 1 (denoted by scenarios 1-4). Both the accumulative temperature-volume histogram and the relative depth-area ratio histogram show that the maximum temperature rise (MTR) is 6.6 and 8 ℃ in scenarios 2 and 3, and they are superior to scenarios 1 and 4. Furthermore, the PMMW can control temperature field distribution of biological tissue. It provides both preliminary basis for thermal volume control and new technology for temperature control and monitor in superficial hyperthermia.展开更多
基金Project(2019M650262)supported by the China Postdoctoral Science FoundationProject(92060106)supported by the Major Research Plan of National Natural Science Foundation of ChinaProject(201803U8003)supported by the China Aeronautical Science Foundation。
文摘The heat generation behaviors of fatigue crack are deeply investigated under different preload forces combing numerical simulation and experiment.Firstly,a multi-contact simulation model is applied to stimulate the crack surfaces contact and the horn-sample contact under ultrasonic excitation for calculating the temperature fields.Then,the ultrasonic infrared thermography testing and the microscope testing are carried out for the heat generation and the plastic deformation behaviors of crack region under different preload forces.On this basis,an indirect observation method based on dots distribution is proposed to estimate the plastic deformation on crack contact surfaces.The obtained results show that the temperature rise of crack region increases with the increase of preload force when the preload force is less than 250 N,while the temperature rise rapidly declines due to the plastic deformation on crack contact surfaces and the inhibition effect when the preload force is 280 N.Moreover,the plastic deformation does not lead to the crack propagation,but reduces the detection repeatability of fatigue crack.This work provides an effective method for optimizing testing conditions in practical testing processes,which will be helpful to the establishment of testing standards for batches of test objects in ultrasonic infrared thermography testing.
基金Project(50977064) supported by the National Natural Science Foundation of China
文摘A 3D temperature field distribution of biological tissue for superficial hyperthermia using a pulse modulated microwave (PMMW) was presented. A 3D sliced homogeneous phantom was radiated by the PMMW and an infrared thermal imager was applied to image temperature distribution throughout the phantom. The period of the PMMW is 3 s and the output power is 35 W. The temperature rises by at least 3 ℃ in the phantom when the duty cycle varies from 1/3, 1/2, 2/3 to 1 (denoted by scenarios 1-4). Both the accumulative temperature-volume histogram and the relative depth-area ratio histogram show that the maximum temperature rise (MTR) is 6.6 and 8 ℃ in scenarios 2 and 3, and they are superior to scenarios 1 and 4. Furthermore, the PMMW can control temperature field distribution of biological tissue. It provides both preliminary basis for thermal volume control and new technology for temperature control and monitor in superficial hyperthermia.