期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Mechanical response of transmission lines based on sliding cable element 被引量:4
1
作者 刘云 钱振东 夏开全 《Journal of Central South University》 SCIE EI CAS 2014年第8期3370-3377,共8页
In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding ca... In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding catenary element considering the out-of-plane stiffness coefficient are put forward.A two-span and a three-span cable structures are taken as examples to verify the sliding cable elements.By comparing the tensions of the two proposed cable elements with the existing research results,the error is less than 1%,which proves the correctness of the proposed elements.The sliding characteristics should be considered in the practical engineering because of the significant difference between the tensions of sliding cable elements and those of cable element without considering sliding.The out-of-plane stiffness coefficient and friction characteristics do not obviously affect the cable tensions. 展开更多
关键词 transmission lines sliding cable element updated Lagrangian formulation geometric nonlinearity mechanical response
在线阅读 下载PDF
Optimal transmission lines assignment with maximal reliabilities in multi-source multi-sink multi-state computer network 被引量:1
2
作者 章筠 徐正国 +2 位作者 王文海 卢建刚 孙优贤 《Journal of Central South University》 SCIE EI CAS 2013年第7期1868-1877,共10页
The optimal transmission lines assignment with maximal reliabilities (OTLAMR) in the multi-source multi-sink multi-state computer network (MMMCN) was investigated. The OTLAMR problem contains two sub-problems: the MMM... The optimal transmission lines assignment with maximal reliabilities (OTLAMR) in the multi-source multi-sink multi-state computer network (MMMCN) was investigated. The OTLAMR problem contains two sub-problems: the MMMCN reliabilities evaluation and multi-objective transmission lines assignment optimization. First, a reliability evaluation with a transmission line assignment (RETLA) algorithm is proposed to calculate the MMMCN reliabilities under the cost constraint for a certain transmission lines configuration. Second, the non-dominated sorting genetic algorithm II (NSGA-II) is adopted to find the non-dominated set of the transmission lines assignments based on the reliabilities obtained from the RETLA algorithm. By combining the RETLA and the NSGA-II algorithms together, the RETLA-NSGA II algorithm is proposed to solve the OTLAMR problem. The experiments result show that the RETLA-NSGA II algorithm can provide efficient solutions in a reasonable time, from which the decision makers can choose the best solution based on their preferences and experiences. 展开更多
关键词 multi-state network reliability evaluation transmission lines assignments multi-objective optimization non-dominatedsorting genetic algorithm II
在线阅读 下载PDF
Competition Mechanism of Lightning Upward Leaders Issued from UHVDC Transmission Lines 被引量:2
3
作者 SHI Wei LI Qingmin +2 位作者 LU Xinchang ZOU Liang SUN Qiuqin 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3206-3214,共9页
关键词 UHVDC transmission line shielding failure numerical simulation leader progression model competitionof upward leaders lightning protection
在线阅读 下载PDF
One modified method of characteristics used to analyze the multiconductor transmission lines
4
作者 Fu Jiwei Hou Chaozhen Dou Lihua 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2006年第1期65-70,共6页
To solve the coupling effect of multiconductor transmission lines excited by external electromagnetic wave, the modified method of characteristics is proposed. The modified method of characteristics which can compute ... To solve the coupling effect of multiconductor transmission lines excited by external electromagnetic wave, the modified method of characteristics is proposed. The modified method of characteristics which can compute the terminal induced voltages excited by the external electromagnetic wave when the terminal networks or intereonnection networks contain the dynamic elements is introduced. The simulation results indicate that the modified method can analyze the terminal induced voltages when the terminal networks or the interconnection networks contain the dynamic elements excited by the external electromagnetic wave. And the results are compared with the results acquired by FDTD method, the two results are completely same. So one effective modified method is implemented to compute the transmission lines. 展开更多
关键词 multiconductor transmission line the method of characteristics dynamic elements.
在线阅读 下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
5
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
在线阅读 下载PDF
Impacts of flexible obstructive working environment on dynamic performances of inspection robot for power transmission line 被引量:7
6
作者 肖晓晖 吴功平 +1 位作者 杜娥 李三平 《Journal of Central South University of Technology》 2008年第6期869-876,共8页
The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's... The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's dynamic performance. First, considering the structure of the obstacles and symmetrical mechanism of the robot prototype, four basic subactions were abstracted to fulfill full-path kinematic tasks. Then, a multi-rigid-body dynamic model of the robot was built with Lagrange equation, whil^e a multi-flexible-body dynamic model of a span of lin~ was obtained by combining finite element method (FEM), modal synthesis method and Lagrange equation. The two subsystem models were coupled under rolling along no-obstacle segment and overcoming obstacle poses, and these simulations of three subactions along different spans of line were performed in ADMAS. The simulation results, including the coupling vibration parameters and driving moment of joint motors, show the dynamic performances of the robot along ftexibile obstructive working path: in flexible obstructive working environment, the robot can fulfill the preset motion goals; it responses slower in more flexible path; the fluctuation of robot as well as driving moment of the corresponding joint in startup and brake region is greater than that in rigid environment; the fluctuation amplitude increases with increasing working environment flexibility. 展开更多
关键词 inspection robot transmission line OBSTRUCTION rigid-flexible coupling dynamics finite element method simulation
在线阅读 下载PDF
Transmission upper limit of band-pass double-layer FSS and method of transmission performance improvement 被引量:2
7
作者 Minjie Huang Zhijun Meng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2015年第2期224-231,共8页
The transmission upper limit of a double-layer frequency selective surface (FSS) with two infinitely thin metal arrays is pre- sented based on the study of the general equivalent transmission line model of a double-... The transmission upper limit of a double-layer frequency selective surface (FSS) with two infinitely thin metal arrays is pre- sented based on the study of the general equivalent transmission line model of a double-layer FSS. Results of theoretical analyses, numerical simulations and experiments show that this transmis- sion upper limit is independent of the array and the element, which indicates that it is impossible to achieve a transmission upper limit higher than this one under a given incident and dielectric- supporting condition by the design of the periodic array. Both the applicable condition and the possible application of the transmis- sion upper limit are discussed. The results show that the transmis- sion upper limit not only has a good reachability, but also provides a key to effectively improve the transmission performance of a double-layer FSS or more complex frequency selective structures. 展开更多
关键词 frequency selective surface(FSS) equivalent circuit transmission line theory dielectric interfaces
在线阅读 下载PDF
Design of a wideband non-uniform microstrip line for complex impedance matching in automotive radar frequencies
8
作者 ZHANG Shuang-Gen YU Tao +2 位作者 WANG Yu-Lan CHENG Zhi-Hua YAO Jian-Quan 《红外与毫米波学报》 北大核心 2025年第2期168-176,共9页
Microstrip transmission lines connecting to the millimeter wave radar chip and antenna significantly affect the radiation efficiency and bandwidth of the antenna.Here,a wideband non-uniform wavy microstrip line for co... Microstrip transmission lines connecting to the millimeter wave radar chip and antenna significantly affect the radiation efficiency and bandwidth of the antenna.Here,a wideband non-uniform wavy microstrip line for complex impedance in automotive radar frequency range is proposed.Unlike the gradient transmission line,the wavy structure is composed of periodically semi-circular segments.By adjusting the radius of the semi-circular,the surface current is varied and concentrated on the semi-circular segments,allowing a wider tunability range of the resonant frequency.The results reveal that the bandwidth of the loaded wavy transmission line antenna improves to 9.37 GHz,which is 5.81 GHz wider than that of the loaded gradient line.The gain and the half power beam width of the loaded antenna are about 14.69 dB and 9.58°,respectively.The proposed non-uniform microstrip line scheme may open up a route for realizing wideband millimeter-wave automotive radar applications. 展开更多
关键词 millimeter wave gradient line wavy transmission line broadband high gain array antenna
在线阅读 下载PDF
交直流混合输电线路空间电场分析(英文) 被引量:6
9
作者 李倩 刘俊翔 +1 位作者 李华 林福昌 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2866-2872,共7页
As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines p... As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines plays an important role in evaluating the electromagnetic environment nearby.However,few existing research now considered the mutual effect of HVAC-HVDC hybrid transmission lines.Thus,this research designed a program based on windows,which calculated the surface voltage gradient on the transmission lines and the electric field at ground level respectively.This research calculated the surface voltage gradient on the transmission lines by applying the improved method of successive images.For the electric field at ground level under AC transmission line,simulation charge method is used,while for the electric field at the ground level under DC transmission lines,deutsch assumption method is used.Comparing the results generated by the calculation with those in published literature,the program is reliable.Taking 500 kV transmission lines as an example,when considering the mutual effect of the HVAC-HVDC lines,the amplitude of the surface voltage gradient will increase by about 10%and the amplitude of the electric field at ground level will increase by about 8%,making the mutual effect of the AC and DC lines unneglectable. Larger part of the electric field at ground level under hybrid lines is produced by the DC line.Thus,in order to control the electric field at ground level under hybrid lines,it should pay more attention on that produced by the DC line. 展开更多
关键词 hybrid transmission lines method of successive images simulation charge method deutsch assumption method conductor surface gradient the ionized field
在线阅读 下载PDF
Hand-eye-vision based control for an inspection robot's autonomous line grasping 被引量:15
10
作者 王伟 吴功平 +6 位作者 白玉成 肖华 杨智勇 严宇 何缘 徐显金 苏帆 《Journal of Central South University》 SCIE EI CAS 2014年第6期2216-2227,共12页
In order to ensure that the off-line arm of a two-arm-wheel combined inspection robot can reliably grasp the line in case of autonomous obstacle crossing,a control method is proposed for line grasping based on hand-ey... In order to ensure that the off-line arm of a two-arm-wheel combined inspection robot can reliably grasp the line in case of autonomous obstacle crossing,a control method is proposed for line grasping based on hand-eye visual servo.On the basis of the transmission line's geometrical characteristics and the camera's imaging principle,a line recognition and extraction method based on structure constraint is designed.The line's intercept and inclination are defined in an imaging space to represent the robot's change of pose and a law governing the pose decoupling servo control is developed.Under the integrated consideration of the influence of light intensity and background change,noise(from the camera itself and electromagnetic field)as well as the robot's kinetic inertia on the robot's imaging quality in the course of motion and the grasping control precision,a servo controller for grasping the line of the robot's off-line arm is designed with the method of fuzzy control.An experiment is conducted on a 1:1 simulation line using an inspection robot and the robot is put into on-line operation on a real overhead transmission line,where the robot can grasp the line within 18 s in the case of autonomous obstacle-crossing.The robot's autonomous line-grasping function is realized without manual intervention and the robot can grasp the line in a precise,reliable and efficient manner,thus the need of actual operation can be satisfied. 展开更多
关键词 inspection robot line grasping control visual servo overhead transmission line autonomous obstacle-crossing
在线阅读 下载PDF
Rigorous analysis of high-frequency characteristics of higher-order depressed MILO slow wave structure 被引量:5
11
作者 Qin Fen Wang Dong +1 位作者 Chen Daibing Wen Jie 《强激光与粒子束》 EI CAS CSCD 北大核心 2013年第B05期119-123,共5页
The slow wave structure(SWS)of higher-order depressed magnetically insulated transmission line oscillator(HDMILO)is analyzed rigorously,and the electromagnetic field distribution is derived.High-frequency analysis res... The slow wave structure(SWS)of higher-order depressed magnetically insulated transmission line oscillator(HDMILO)is analyzed rigorously,and the electromagnetic field distribution is derived.High-frequency analysis results reveal that the degeneracy of two degenerate HEM!1 modes is removed by the slot in swS plate and the two degenerate modes split into two modes which polarize perpendicularly.Adjusting the azi-muthal position of the slots destroys longitudinal oscillation condition of higher-order modes. 展开更多
关键词 high power microwave magnetically insulated transmission line oscillator(MILO) slow wave structure high-frequency characteristics I HEM mode fundamental mode
在线阅读 下载PDF
高压输电线路雷击闪络的实验室研究(英文) 被引量:3
12
作者 Thongchai Disyadej Stanislaw Grzybowski 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2707-2714,共8页
This paper presents an investigation on the attractive width of high voltage transmission lines to lightning strikes.In order to design the optimal lightning protection,the estimated number of lightning flashes on the... This paper presents an investigation on the attractive width of high voltage transmission lines to lightning strikes.In order to design the optimal lightning protection,the estimated number of lightning flashes on the line, which is based on its attractive width,needs to be determined.The investigation was performed using experiments with model tests at the Mississippi State University High Voltage Laboratory.For laboratory experiments,a total of 2,100 negative and positive switching impulse voltages were applied to transmission line models from a conducting rod,which represented a lightning downward leader.Different tested models of transmission lines on a scale of 1:100 were used.The effects of overhead ground wires,phase conductors,tower structures,and the magnitude and polarity of lightning strokes were also studied.The attractive width increased gradually with the height of overhead ground wires and towers as well as the magnitude of the lightning stroke current.Impulse polarity had an impact on the attractive width,and the attractive width for negative polarity was larger than that for positive polarity.The taller tower had more effect on flash distribution to transmission lines than the shorter one.The experimental results agree with the actual transmission line observations published in literature.The new expressions for the attractive width of transmission lines,based on the experimental results,were established.The accurate estimation of the attractive width can help electric power utilities plan transmission systems reliably and economically.The detailed description of the background problem,proposed method,experimental results,and analysis are presented in this paper. 展开更多
关键词 LIGHTNING high voltage transmission line laboratory experiment test model
在线阅读 下载PDF
Investigation on Suspended Stripline and End-Coupled Bandpass Filter 被引量:1
13
作者 Jinxiong Xie, student member, IEEE, and Weigan Lin, senior member, IEEEUniversity of Electronic Science and Technology of China, Chengdu 610054, China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1991年第2期82-90,共9页
In this paper, the variational method combined with Green's function is used to analyze the characteristics of suspended, stripline. The result is in good agreement with references. The design of mm-wave end-coupl... In this paper, the variational method combined with Green's function is used to analyze the characteristics of suspended, stripline. The result is in good agreement with references. The design of mm-wave end-coupled bandpass filter with suspended substrate is discussed. The computer programs for design of suspended stripline and bandpass filter are established. 展开更多
关键词 Millimeter wave Millimeter wave transmission line Millimeter wave passive component Bandpass filter Computer aided design.
在线阅读 下载PDF
Novel LDNMOS embedded SCR with strong ESD robustness based on 0.5 μm 18 V CDMOS technology
14
作者 汪洋 金湘亮 周阿铖 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期552-559,共8页
A novel LDNMOS embedded silicon controlled rectifier(SCR) was proposed to enhance ESD robustness of high-voltage(HV) LDNMOS based on a 0.5 μm 18 V CDMOS process. A two-dimensional(2D) device simulation and a transmis... A novel LDNMOS embedded silicon controlled rectifier(SCR) was proposed to enhance ESD robustness of high-voltage(HV) LDNMOS based on a 0.5 μm 18 V CDMOS process. A two-dimensional(2D) device simulation and a transmission line pulse(TLP) testing were used to analyze the working mechanism and ESD performance of the novel device. Compared with the traditional GG-LDNMOS, the secondary breakdown current(It2) of the proposed device can successfully increase from 1.146 A to 3.169 A with a total width of 50 μm, and ESD current discharge efficiency is improved from 0.459 m A/μm2 to 1.884 m A/μm2. Moreover, due to their different turn-on resistances(Ron), the device with smaller channel length(L) owns a stronger ESD robustness per unit area. 展开更多
关键词 LDNMOS embedded SCR TCAD simulation electrostatic discharge(ESD) robustness transmission line pulse(TLP)
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部