In this paper, based on the improved complex variable moving least-square (ICVMLS) approximation, a new complex variable meshless method (CVMM) for two-dimensional (2D) transient heat conduction problems is pres...In this paper, based on the improved complex variable moving least-square (ICVMLS) approximation, a new complex variable meshless method (CVMM) for two-dimensional (2D) transient heat conduction problems is presented. The variational method is employed to obtain the discrete equations, and the essential boundary conditions are imposed by the penalty method. As the transient heat conduction problems are related to time, the Crank-Nicolson difference scheme for two-point boundary value problems is selected for the time discretization. Then the corresponding formulae of the CVMM for 2D heat conduction problems are obtained. In order to demonstrate the applicability of the proposed method, numerical examples are given to show the high convergence rate, good accuracy, and high efficiency of the CVMM presented in this paper.展开更多
Tunneling machines, or excavators, are large and good conductors and affect the reliability of data gathering and interpretation in advanced detection using transient electromagnetic methods. In our experiment, we use...Tunneling machines, or excavators, are large and good conductors and affect the reliability of data gathering and interpretation in advanced detection using transient electromagnetic methods. In our experiment, we used a coincident-loop and central loop type of configuration, where the coil plane l) vertical to and 2) parallel to the working face. A SIROTEM instrument at different locations was used to observe the transient electromagnetic responses of the excavator and to analyze the response amplitudes. The result shows that the tunneling machine affects the advanced detection data and is related to the way the coil is coupled. When the excavator is 6 m from the observatory, the interference of tunneling machine can be ignored.展开更多
Buried water-conducting and water-bearing structures in front of the driving head may easily lead to water bursts in coal mines. Therefore,it is very important for the safety of production to make an accurate and time...Buried water-conducting and water-bearing structures in front of the driving head may easily lead to water bursts in coal mines. Therefore,it is very important for the safety of production to make an accurate and timely forecast about water bursts. Based on the smoke ring effect of transient electromagnetic fields,the principle of transient electro-magnetic method used in detecting buried water-bearing structures in coal mines in advance,is discussed. Small multi-turn loop configurations used in coal mines are proposed and a field procedure of semicircular sector scanning is presented. The application of this method in one coal mine indicates that the technology has many advantages compared with others. The method is inexpensive,highly accurate and efficient. Suggestions are presented for future solutions to some remaining problems.展开更多
In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE metho...In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE method not only conveniently imposes the essential boundary conditions, but also exploits the advantages of the individual methods while avoiding their disadvantages, then the computational efficiency is higher. A hybrid approximation function is applied to combine the CVRKP method with the FE method, and the traditional difference method for two-point boundary value problems is selected as the time discretization scheme. The corresponding formulations of the CVRKP-FE method are presented in detail. Several selected numerical examples of the transient heat conduction problems are presented to illustrate the performance of the CVRKP-FE method.展开更多
Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider band...Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer.展开更多
Two floating structures in close proximity are very commonly seen in offshore engineering. They are often subjected to steep waves and, therefore, the transient effects on their hydrodynamic features are of great conc...Two floating structures in close proximity are very commonly seen in offshore engineering. They are often subjected to steep waves and, therefore, the transient effects on their hydrodynamic features are of great concem. This paper uses the quasi arbitrary Lagrangian Eulerian finite element method (QALE-FEM), based on the fully nonlinear potential theory (FNPT), to numerically investigate the interaction between two 3-D floating structures, which undergo motions with 6 degrees of freedom (DOFs), and are subjected to waves with different incident angles. The transient behaviours of floating structures, the effect of the accompanied structures, and the nonlinearity on the motion of and the wave loads on the structures are the main focuses of the study. The investigation reveals an important transient effects causing considerably larger structure motion than that in steady state. The results also indicate that the accompanied structure in close proximity enhances the interaction between different motion modes and results in stronger nonlinearity causing 2hal-order component to be of similar significance to the fundamental one.展开更多
A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especia...A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.展开更多
Thermal conductivity is an important material parameter of silicon when studying the performance and reliability of devices or for guiding circuit design when considering heat dissipation, especially when the self-hea...Thermal conductivity is an important material parameter of silicon when studying the performance and reliability of devices or for guiding circuit design when considering heat dissipation, especially when the self-heating effect becomes prominent in ultra-scaled MOSFETs.The cross-plane thermal conductivity of a thin silicon film is lacking due to the difficulty in sensing high thermal conductivity in the vertical direction.In this paper, a feasible method that utilizes an ultra-fast electrical pulse within 20 μs combined with the hot strip technique is adopted.To the best of our knowledge, this is the first work that shows how to extract the cross-plane thermal conductivity of sub-50 nm(30 nm, 17 nm, and 10 nm)silicon films on buried oxide.The ratio of the extracted cross-plane thermal conductivity of the silicon films over the bulk value is only about 6.9%, 4.3%, and 3.8% at 300 K, respectively.As the thickness of the films is smaller than the phonon mean free path, the classical heat transport theory fails to predict the heat dissipation in nanoscale transistors.Thus, in this study, a ballistic model, derived from the heat transport equation based on extended-irreversible-hydrodynamics(EIT), is used for further investigation, and the simulation results exhibit good consistence with the experimental data.The extracted effective thermal data could provide a good reference for precise device simulations and thermoelectric applications.展开更多
On the basis of the complex variable moving least-square (CVMLS) approximation, a complex variable meshless local Petrov-Galerkin (CVMLPG) method is presented for transient heat conduction problems. The method is ...On the basis of the complex variable moving least-square (CVMLS) approximation, a complex variable meshless local Petrov-Galerkin (CVMLPG) method is presented for transient heat conduction problems. The method is developed based on the CVMLS approximation for constructing shape functions at scattered points, and the Heaviside step function is used as a test function in each sub-domain to avoid the need for a domain integral in symmetric weak form. In the construction of the well-performed shape function, the trial function of a two-dimensional (2D) problem is formed with a one-dimensional (1D) basis function, thus improving computational efficiency. The numerical results are compared with the exact solutions of the problems and the finite element method (FEM). This comparison illustrates the accuracy as well as the capability of the CVMLPG method.展开更多
The smoothing thin plate spline (STPS) interpolation using the penalty function method according to the optimization theory is presented to deal with transient heat conduction problems. The smooth conditions of the ...The smoothing thin plate spline (STPS) interpolation using the penalty function method according to the optimization theory is presented to deal with transient heat conduction problems. The smooth conditions of the shape functions and derivatives can be satisfied so that the distortions hardly occur. Local weak forms are developed using the weighted residual method locally from the partial differential equations of the transient heat conduction. Here the Heaviside step function is used as the test function in each sub-domain to avoid the need for a domain integral. Essential boundary conditions can be implemented like the finite element method (FEM) as the shape functions possess the Kronecker delta property. The traditional two-point difference method is selected for the time discretization scheme. Three selected numerical examples are presented in this paper to demonstrate the availability and accuracy of the present approach comparing with the traditional thin plate spline (TPS) radial basis functions.展开更多
This study used the stable and convergent Dufort-Frankel method to differentially discretize the diffusion equation of the ground-well transient electromagnetic secondary field.The absorption boundary condition of com...This study used the stable and convergent Dufort-Frankel method to differentially discretize the diffusion equation of the ground-well transient electromagnetic secondary field.The absorption boundary condition of complex frequency-shifted perfectly matched layer(CFS-PML)was used for truncation so that the low-frequency electromagnetic wave can be better absorbed at the model boundary.A typical three-dimensional(3D)homogeneous half-space model was established and a low-resistivity cube model was analyzed under the half-space condition.The response patterns and drivers of the low-resistivity cube model were discussed under the influence of a low-resistivity overburden.The absorption boundary conditions of CFS-PML significantly affected the low-frequency electromagnetic waves.For a low-resistivity cube around the borehole,its response curve exhibited a single-peak,and the extreme point of the curve corresponded to the center of the low-resistivity body.When the low-resistivity cube was directly below the borehole,the response curve showed three extreme values(two high and one low),with the low corresponding to the center of the low-resistivity body.The total field response of the low-resistivity overburden was stronger than that of the uniform half-space model due to the low-resistivity shielding effect of electromagnetic waves.When the receiving-transmitting distance gradually increased,the effect of the low-resistivity overburden was gradually weakened,and the response of the low-resistivity cube was strengthened.It was affected by the ratio of the overburden resistivity to the resistivity of the low-resistivity body.展开更多
This article presents a modeling and simulation method for transient thermal analyses of integrated circuits(ICs)using the original and voltage-in-current(VinC)latency insertion method(LIM).LIM-based algorithms are a ...This article presents a modeling and simulation method for transient thermal analyses of integrated circuits(ICs)using the original and voltage-in-current(VinC)latency insertion method(LIM).LIM-based algorithms are a set of fast transient simulation methods that solve electrical circuits in a leapfrog updating manner without relying on large matrix operations used in conventional Simulation Program with Integrated Circuit Emphasis(SPICE)-based methods which can significantly slow down the solution process.The conversion from the thermal to electrical model is performed first by using the analogy between heat and electrical conduction.Since electrical inductance has no thermal equivalence,a modified VinC LIM formulation is presented which removes the requirement of the insertion of fictitious inductors.Numerical examples are presented,which show that the modified VinC LIM formulation outperforms the basic LIM formulation,in terms of both stability and accuracy in the transient thermal simulation of ICs.展开更多
Due to the wide application of closely spaced multi-well horizontal pads for developing unconventional gas reservoirs,interference between wells becomes a significant concern.Communication between wells mainly occurs ...Due to the wide application of closely spaced multi-well horizontal pads for developing unconventional gas reservoirs,interference between wells becomes a significant concern.Communication between wells mainly occurs through natural fractures.However,previous studies have found that interwell communication through natural fractures is varied,and non-communication also appears in the mid and late stages of production due to natural fracture closure.This study proposes a boundary element method for coupling multi-connected regions for the first time.Using this method,we coupled multiple flow fields to establish dual-well models with various connectivity conditions of the stimulated reservoir volume(SRV)region.These models also take into consideration of adsorption and desorption mechanism of natural gas as well as the impact of fracturing fluid retention.The study found that when considering the non-communication of SRV regions between multi-well horizontal pads,the transient behavior of the targeted well exhibits a transitional flow stage occurring before the well interference flow stage.In addition,sensitivity analysis shows that the well spacing and production regime,as well as the connectivity conditions of the SRV region,affect the timing of interwell interference.Meanwhile,the productivity of the two wells,reservoir properties,and fracturing operations affect the intensity of interwell interference.展开更多
瞬变电磁远探测在探测深度和分辨率方面,填补了常规测井和地震勘探的地质评价尺度空白带。但是,目前建立在各向同性介质基础上的理论模型,与我国大多数地区油气田客观存在的开发环境,即非均质、各向异性地层的事实不符。目的考虑到地下...瞬变电磁远探测在探测深度和分辨率方面,填补了常规测井和地震勘探的地质评价尺度空白带。但是,目前建立在各向同性介质基础上的理论模型,与我国大多数地区油气田客观存在的开发环境,即非均质、各向异性地层的事实不符。目的考虑到地下介质的复杂性和非均质性等特点,针对各向异性地层中的井孔瞬变电磁法研究具有重要意义。方法基于井孔瞬变电磁理论,通过研究三轴感应数据,采用解析计算方式推导各向异性地层井孔瞬变电磁视电阻率、视倾角关系表达式,通过建立水平和倾斜各向异性地层模型对视电阻率和视倾角进行计算与分析。结果结果表明:对于均匀各向同性介质模型,视电阻率可以较好反映地层阻值变化情况,视倾角与模型地层倾角基本吻合;对于垂直对称轴横向各向同性(transversely isotropic media with a vertical symmetry axis,VTI)的各向异性介质模型,视电阻率与视倾角能够较好反映各向异性地层的水平、垂直电阻率和倾角。结论井孔瞬变电磁响应能够快速计算出各向异性地层中视电阻率和视倾角,有助于快速分析观测装置附近电性结构,对各向异性介质井孔瞬变电磁领域的快速发展具有重要意义。展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.11171208)the Shanghai Leading Academic Discipline Project,China(Grant No.S30106)the Innovation Fund for Graduate Student of Shanghai University of China (Grant No.SHUCX120125)
文摘In this paper, based on the improved complex variable moving least-square (ICVMLS) approximation, a new complex variable meshless method (CVMM) for two-dimensional (2D) transient heat conduction problems is presented. The variational method is employed to obtain the discrete equations, and the essential boundary conditions are imposed by the penalty method. As the transient heat conduction problems are related to time, the Crank-Nicolson difference scheme for two-point boundary value problems is selected for the time discretization. Then the corresponding formulae of the CVMM for 2D heat conduction problems are obtained. In order to demonstrate the applicability of the proposed method, numerical examples are given to show the high convergence rate, good accuracy, and high efficiency of the CVMM presented in this paper.
基金support received from the National Basic Research Program of China (No2007CB209400)the National Natural Science Foundation of China (No50774085)the Young Scientists Fund of the School Science Foundation of CUMT (No2008A046)
文摘Tunneling machines, or excavators, are large and good conductors and affect the reliability of data gathering and interpretation in advanced detection using transient electromagnetic methods. In our experiment, we used a coincident-loop and central loop type of configuration, where the coil plane l) vertical to and 2) parallel to the working face. A SIROTEM instrument at different locations was used to observe the transient electromagnetic responses of the excavator and to analyze the response amplitudes. The result shows that the tunneling machine affects the advanced detection data and is related to the way the coil is coupled. When the excavator is 6 m from the observatory, the interference of tunneling machine can be ignored.
基金Project 40674074 supported by the National Natural Science Foundation of China20050290501 by the Specialized Research Fund for the Doctoral Programof Higher EducationD200409 by the Scientific Research Fund for Youth of China University of Mining & Technology
文摘Buried water-conducting and water-bearing structures in front of the driving head may easily lead to water bursts in coal mines. Therefore,it is very important for the safety of production to make an accurate and timely forecast about water bursts. Based on the smoke ring effect of transient electromagnetic fields,the principle of transient electro-magnetic method used in detecting buried water-bearing structures in coal mines in advance,is discussed. Small multi-turn loop configurations used in coal mines are proposed and a field procedure of semicircular sector scanning is presented. The application of this method in one coal mine indicates that the technology has many advantages compared with others. The method is inexpensive,highly accurate and efficient. Suggestions are presented for future solutions to some remaining problems.
基金Project supported by the National Natural Science Foundation of China (Grant No. 11171208)the Special Fund for Basic Scientific Research of Central Colleges of Chang’an University, China (Grant No. CHD2011JC080)
文摘In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE method not only conveniently imposes the essential boundary conditions, but also exploits the advantages of the individual methods while avoiding their disadvantages, then the computational efficiency is higher. A hybrid approximation function is applied to combine the CVRKP method with the FE method, and the traditional difference method for two-point boundary value problems is selected as the time discretization scheme. The corresponding formulations of the CVRKP-FE method are presented in detail. Several selected numerical examples of the transient heat conduction problems are presented to illustrate the performance of the CVRKP-FE method.
基金supported by the State Grid Corporation Science and Technology Project(No.JL71-15-039)
文摘Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer.
基金Supported by EPSRC/FSC (EP/I502033/1) and Leverhulme Trust (ECF/40348), UK
文摘Two floating structures in close proximity are very commonly seen in offshore engineering. They are often subjected to steep waves and, therefore, the transient effects on their hydrodynamic features are of great concem. This paper uses the quasi arbitrary Lagrangian Eulerian finite element method (QALE-FEM), based on the fully nonlinear potential theory (FNPT), to numerically investigate the interaction between two 3-D floating structures, which undergo motions with 6 degrees of freedom (DOFs), and are subjected to waves with different incident angles. The transient behaviours of floating structures, the effect of the accompanied structures, and the nonlinearity on the motion of and the wave loads on the structures are the main focuses of the study. The investigation reveals an important transient effects causing considerably larger structure motion than that in steady state. The results also indicate that the accompanied structure in close proximity enhances the interaction between different motion modes and results in stronger nonlinearity causing 2hal-order component to be of similar significance to the fundamental one.
基金Supported by the National Natural Science Foundation of China under Grant Nos 51137004,61427806 and 51577184the Equipment Development Project of Chinese Academy of Sciences under Grant No YZ201507
文摘A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.
基金Project supported by the Zhejiang Provincial Natural Science Foundation of China(Grant No.LZ19F040001)the National Natural Science Foundation of China(Grant No.61473287)the NSFC–Zhejiang Joint Fund for the Integration of Industrialization Informatization,China(Grant No.U1609213)
文摘Thermal conductivity is an important material parameter of silicon when studying the performance and reliability of devices or for guiding circuit design when considering heat dissipation, especially when the self-heating effect becomes prominent in ultra-scaled MOSFETs.The cross-plane thermal conductivity of a thin silicon film is lacking due to the difficulty in sensing high thermal conductivity in the vertical direction.In this paper, a feasible method that utilizes an ultra-fast electrical pulse within 20 μs combined with the hot strip technique is adopted.To the best of our knowledge, this is the first work that shows how to extract the cross-plane thermal conductivity of sub-50 nm(30 nm, 17 nm, and 10 nm)silicon films on buried oxide.The ratio of the extracted cross-plane thermal conductivity of the silicon films over the bulk value is only about 6.9%, 4.3%, and 3.8% at 300 K, respectively.As the thickness of the films is smaller than the phonon mean free path, the classical heat transport theory fails to predict the heat dissipation in nanoscale transistors.Thus, in this study, a ballistic model, derived from the heat transport equation based on extended-irreversible-hydrodynamics(EIT), is used for further investigation, and the simulation results exhibit good consistence with the experimental data.The extracted effective thermal data could provide a good reference for precise device simulations and thermoelectric applications.
基金supported by the National Natural Science Foundation of China(Grant No.51078250)the Research Project by Shanxi Scholarship Council of Shanxi Province,China(Grant No.2013-096)the Scientific&Technological Innovation Program for Postgraduates of Taiyuan University of Science and Technology,China(Grant No.20125026)
文摘On the basis of the complex variable moving least-square (CVMLS) approximation, a complex variable meshless local Petrov-Galerkin (CVMLPG) method is presented for transient heat conduction problems. The method is developed based on the CVMLS approximation for constructing shape functions at scattered points, and the Heaviside step function is used as a test function in each sub-domain to avoid the need for a domain integral in symmetric weak form. In the construction of the well-performed shape function, the trial function of a two-dimensional (2D) problem is formed with a one-dimensional (1D) basis function, thus improving computational efficiency. The numerical results are compared with the exact solutions of the problems and the finite element method (FEM). This comparison illustrates the accuracy as well as the capability of the CVMLPG method.
基金supported by the Key Program of the National Natural Science Foundation of China (Grand No. 51138001)the China-German Cooperation Project (Grand No. GZ566)+1 种基金the Innovative Research Groups Funded by the National Natural Science Foundation of China (Grand No. 51121005)the Special Funds for the Basic Scientific Research Expenses for the Central University (Grant No. DUT13LK16)
文摘The smoothing thin plate spline (STPS) interpolation using the penalty function method according to the optimization theory is presented to deal with transient heat conduction problems. The smooth conditions of the shape functions and derivatives can be satisfied so that the distortions hardly occur. Local weak forms are developed using the weighted residual method locally from the partial differential equations of the transient heat conduction. Here the Heaviside step function is used as the test function in each sub-domain to avoid the need for a domain integral. Essential boundary conditions can be implemented like the finite element method (FEM) as the shape functions possess the Kronecker delta property. The traditional two-point difference method is selected for the time discretization scheme. Three selected numerical examples are presented in this paper to demonstrate the availability and accuracy of the present approach comparing with the traditional thin plate spline (TPS) radial basis functions.
基金This work was supported by China Postdoctoral Science Foundation(No.2022M723391)the Science and Technology Innovation Project of Higher Education in Shanxi Province(No.2019L0754)+1 种基金the Central Guiding Local Science and Technology Development Fund Project(No.YDZJSX2021B021)Shanxi Province Basic Research Plan General Project(No.202203021221294).
文摘This study used the stable and convergent Dufort-Frankel method to differentially discretize the diffusion equation of the ground-well transient electromagnetic secondary field.The absorption boundary condition of complex frequency-shifted perfectly matched layer(CFS-PML)was used for truncation so that the low-frequency electromagnetic wave can be better absorbed at the model boundary.A typical three-dimensional(3D)homogeneous half-space model was established and a low-resistivity cube model was analyzed under the half-space condition.The response patterns and drivers of the low-resistivity cube model were discussed under the influence of a low-resistivity overburden.The absorption boundary conditions of CFS-PML significantly affected the low-frequency electromagnetic waves.For a low-resistivity cube around the borehole,its response curve exhibited a single-peak,and the extreme point of the curve corresponded to the center of the low-resistivity body.When the low-resistivity cube was directly below the borehole,the response curve showed three extreme values(two high and one low),with the low corresponding to the center of the low-resistivity body.The total field response of the low-resistivity overburden was stronger than that of the uniform half-space model due to the low-resistivity shielding effect of electromagnetic waves.When the receiving-transmitting distance gradually increased,the effect of the low-resistivity overburden was gradually weakened,and the response of the low-resistivity cube was strengthened.It was affected by the ratio of the overburden resistivity to the resistivity of the low-resistivity body.
基金This work was supported by the Fundamental Research Grant Scheme(FRGS)sponsored by the Ministry of Higher Education,Malaysia under Grant No.FRGS/1/2020/TK0/USM/02/7.
文摘This article presents a modeling and simulation method for transient thermal analyses of integrated circuits(ICs)using the original and voltage-in-current(VinC)latency insertion method(LIM).LIM-based algorithms are a set of fast transient simulation methods that solve electrical circuits in a leapfrog updating manner without relying on large matrix operations used in conventional Simulation Program with Integrated Circuit Emphasis(SPICE)-based methods which can significantly slow down the solution process.The conversion from the thermal to electrical model is performed first by using the analogy between heat and electrical conduction.Since electrical inductance has no thermal equivalence,a modified VinC LIM formulation is presented which removes the requirement of the insertion of fictitious inductors.Numerical examples are presented,which show that the modified VinC LIM formulation outperforms the basic LIM formulation,in terms of both stability and accuracy in the transient thermal simulation of ICs.
基金supported by the National Science Fund for Excellent Young Scholars(No.52222402)State Key Program of National Natural Science Foundation of China(No.U23A2022)+7 种基金State Key Program of National Natural Science Foundation of China(No.52234003)Sichuan Science and Technology Program(No.2022JDJQ0009)National Natural Science Foundation of China(No.52074235)Science and Technology Cooperation Project of the CNPC-SWPU Innovation Alliance(Nos.2020CX020202 and 2020CX030202)Shale Gas industry Development Institute of Sichuan Province111 Project(No.D18016)China Postdoctoral Science Foundation(No.2022M722637)the Science Foundation of Sichuan Province(No.2022NSFSC0186)。
文摘Due to the wide application of closely spaced multi-well horizontal pads for developing unconventional gas reservoirs,interference between wells becomes a significant concern.Communication between wells mainly occurs through natural fractures.However,previous studies have found that interwell communication through natural fractures is varied,and non-communication also appears in the mid and late stages of production due to natural fracture closure.This study proposes a boundary element method for coupling multi-connected regions for the first time.Using this method,we coupled multiple flow fields to establish dual-well models with various connectivity conditions of the stimulated reservoir volume(SRV)region.These models also take into consideration of adsorption and desorption mechanism of natural gas as well as the impact of fracturing fluid retention.The study found that when considering the non-communication of SRV regions between multi-well horizontal pads,the transient behavior of the targeted well exhibits a transitional flow stage occurring before the well interference flow stage.In addition,sensitivity analysis shows that the well spacing and production regime,as well as the connectivity conditions of the SRV region,affect the timing of interwell interference.Meanwhile,the productivity of the two wells,reservoir properties,and fracturing operations affect the intensity of interwell interference.
文摘瞬变电磁远探测在探测深度和分辨率方面,填补了常规测井和地震勘探的地质评价尺度空白带。但是,目前建立在各向同性介质基础上的理论模型,与我国大多数地区油气田客观存在的开发环境,即非均质、各向异性地层的事实不符。目的考虑到地下介质的复杂性和非均质性等特点,针对各向异性地层中的井孔瞬变电磁法研究具有重要意义。方法基于井孔瞬变电磁理论,通过研究三轴感应数据,采用解析计算方式推导各向异性地层井孔瞬变电磁视电阻率、视倾角关系表达式,通过建立水平和倾斜各向异性地层模型对视电阻率和视倾角进行计算与分析。结果结果表明:对于均匀各向同性介质模型,视电阻率可以较好反映地层阻值变化情况,视倾角与模型地层倾角基本吻合;对于垂直对称轴横向各向同性(transversely isotropic media with a vertical symmetry axis,VTI)的各向异性介质模型,视电阻率与视倾角能够较好反映各向异性地层的水平、垂直电阻率和倾角。结论井孔瞬变电磁响应能够快速计算出各向异性地层中视电阻率和视倾角,有助于快速分析观测装置附近电性结构,对各向异性介质井孔瞬变电磁领域的快速发展具有重要意义。