The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve...The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct.展开更多
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl...The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.展开更多
In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperatur...In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperature swing can be equivalent to reducing maximum instantaneous phase copper loss in this paper.First,a two-level optimization aiming at minimizing maximum instantaneous phase copper loss at each electrical angle is proposed.Then,the optimization is transformed to a singlelevel optimization by introducing the auxiliary variable for easy solving.Considering that singleobjective optimization trades a great total copper loss for a small reduction of maximum phase copper loss,the optimization considering both instantaneous total copper loss and maximum phase copper loss is proposed,which has the same performance of temperature swing reduction but with lower total loss.In this way,the proposed control scheme can reduce maximum junction temperature by 11%.Both simulation and experimental results are presented to prove the effectiveness and superiority of the proposed control scheme for low-frequency temperature swing reduction.展开更多
This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim...This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.展开更多
The tensile strain in inorganic perovskite films induced by thermal annealing is one of the primary factors contributing to the inefficiency and instability of inorganic perovskite solar cells(IPSCs),which reduces the...The tensile strain in inorganic perovskite films induced by thermal annealing is one of the primary factors contributing to the inefficiency and instability of inorganic perovskite solar cells(IPSCs),which reduces the defect formation energy.Here,a flexible molecule 5-maleimidovaleric acid(5-MVA)was introduced as a strain buffer to release the residual strain of CsPbI_(2.85)Br_(0.15)perovskite.Maleic anhydride and carboxyl groups in 5-MVA interact strongly with the uncoordinated Pb^(2+)through Lewis acid-base reaction,thus tightly“pull”the perovskite lattice.The in-between soft carbon chain increased the structural flexibility of CsPbI_(2.85)Br_(0.15)perovskite materials,which effectively relieved the intrinsic internal strain of CsPbI_(2.85)Br_(0.15),resisted the corrosion of external strain,and also reduced the formation of defects such as VIand Pb0.In addition,the introduction of 5-MVA improved crystal quality,passivated residual defects,and narrowed energy level barriers.Eventually,power conversion efficiency(PCE)of NiOxbased inverted IPSCs increased from 19.25%to 20.82%with the open-circuit voltage enhanced from 1.164 V to 1.230 V.The release of strain also improved the stability of CsPbI_(2.85)Br_(0.15)perovskite films and devices.展开更多
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple...A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.展开更多
The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs wavefo...The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.展开更多
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act...For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.展开更多
DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the pa...DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.展开更多
A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft swi...A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.展开更多
Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A ...Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.展开更多
Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width mo...Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width modulation (SPWM) inverters with low harmonyic content in theory.The THD value would be increased by switching time delay of power devices and control circuit. A new control coecuit with delay time compensation is presented in this paper. With this control scheme, the output of the inverter could be basically identified with the theory given.Test results of experimental circuit verify that the control circuit presented in this paper is feasible. The THD of the inverter output voltage could be reduced to a certain extent by this method.展开更多
Constructing heterojunction is an effective strategy to develop high-performance non-preciousmetal-based catalysts for electrochemical water splitting(WS).Herein,we design and prepare an N-doped-carbon-encapsulated Ni...Constructing heterojunction is an effective strategy to develop high-performance non-preciousmetal-based catalysts for electrochemical water splitting(WS).Herein,we design and prepare an N-doped-carbon-encapsulated Ni/MoO_(2) nano-needle with three-phase heterojunction(Ni/MoO_(2)@CN)for accelerating the WS under industrial alkaline condition.Density functional theory calculations reveal that the electrons are redistributed at the three-phase heterojunction interface,which optimizes the adsorption energy of H-and O-containing intermediates to obtain the best ΔG_(H*) for hydrogen evolution reaction(HER)and decrease the ΔG value of ratedetermining step for oxygen evolution reaction(OER),thus enhancing the HER/OER catalytic activity.Electrochemical results confirm that Ni/MoO_(2)@CN exhibits good activity for HER(ƞ_(-10)=33 mV,ƞ_(-1000)=267 mV)and OER(ƞ_(10)=250 mV,ƞ_(1000)=420 mV).It shows a low potential of 1.86 V at 1000 mA cm^(−2) for WS in 6.0 M KOH solution at 60℃ and can steadily operate for 330 h.This good HER/OER performance can be attributed to the three-phase heterojunction with high intrinsic activity and the self-supporting nano-needle with more active sites,faster mass diffusion,and bubbles release.This work provides a unique idea for designing high efficiency catalytic materials for WS.展开更多
Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab...Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.展开更多
A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands ...A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands the capacity of controller. The relationship between stator's voltage and that of current under rotor's flux-oriented-coordinates is first introduced, and then the structure of vector control is analyzed, in which voltage compensation is inducted as the core feedback procedure. Experiments prove that, together with a facility for realization, a smooth transition, a prompt torque response and small concussion are gained. Extensive research conducted by varying parameters that result in practical ripple is proposed in conclusion.展开更多
A three-phase reactor mathematical model was set up to simulate and design a three-phase bubble column reactor for direct synthesis of dimethyl ether (DME) from syngas, considering both the influence of part inert c...A three-phase reactor mathematical model was set up to simulate and design a three-phase bubble column reactor for direct synthesis of dimethyl ether (DME) from syngas, considering both the influence of part inert carrier backmixing on transfer and the influence of catalyst grain sedimentation on reaction. On the basis of this model, the influences of the size and reaction conditions of a 100000 t/a DME reactor on capacity were investigated. The optimized size of the 10000 t/a DME synthesis reactor was proposed as follows: diameter 3.2 m, height 20 m, built-in 400 tube heat exchanger (Ф 38×2 mm), and inert heat carrier paraffin oil 68 t and catalyst 34.46 t. Reaction temperature and pressure were important factors influencing the reaction conversion for different size reactors. Under the condition of uniform catalyst concentration distribution, higher pressure and temperature were proposed to achieve a higher production capacity of DME. The best ratio of fresh syngas for DME synthesis was 2.04.展开更多
The thermal failure induced by high power microwave(HPM) in a complementary metal oxide semiconductor(CMOS) inverter is investigated and its dependence on microwave parameters is discussed in detail. An analytical...The thermal failure induced by high power microwave(HPM) in a complementary metal oxide semiconductor(CMOS) inverter is investigated and its dependence on microwave parameters is discussed in detail. An analytical model of the temperature distribution is established and the relationships between hotspot temperature and pulse width and between hotspot temperature and frequency are predicted, which reveals a more severe rise in temperature under the influence of microwave with longer width and lower frequency. The temperature variation mechanism and the theoretical temperature model are validated and explained by the simulation. Furthermore, variation trend of damage threshold with microwave parameters is derived theoretically, and the conclusions are consistent with simulation results and reported data.展开更多
Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However...Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However,sub-networks,such as a microgrids containing inverter power sources,may be disconnected from the utility network and operated in a standalone mode during extended blackouts.This study focuses on a standalone microgrid supplied by inverter power sources without a synchronous generator and proposes a new microgrid inverter control.In this inverter control,a single grid forming inverter is operated as a master power source to determine frequency and voltage,and other inverters,called grid following inverters,are operated as subordinate power sources with active and reactive power control.The necessary functions in the energy management system are examined,and the coordinated operation of all inverters in the microgrid is demonstrated via simulation.展开更多
As an alternative to conventional energy conversion and storage reactions,gas-involved electrochemical reactions,including the carbon dioxide reduction reaction(CO_(2)RR),nitrogen reduction reaction(NRR)and hydrogen e...As an alternative to conventional energy conversion and storage reactions,gas-involved electrochemical reactions,including the carbon dioxide reduction reaction(CO_(2)RR),nitrogen reduction reaction(NRR)and hydrogen evolution reaction(HER),have become an emerging research direction and have gained increasing attention due to their advantages of environmental friendliness and sustainability.Various studies have been designed to accelerate sluggish kinetics but with limited results.Most of them promote the reaction by modulating the intrinsic properties of the catalyst,ignoring the synergistic effect of the reaction as a whole.Due to the introduction of gas,traditional liquid-solid two-phase reactions are no longer applicable to future research.Since gas-involved electrochemical reactions mostly occur at the junctions of gaseous reactants,liquid electrolytes and solid catalysts,the focus of future research on reaction kinetics should gradually shift to three-phase reaction interfaces.In this review,we briefly introduce the formation and constraints of the three-phase interface and propose three criteria to judge its merit,namely,the active site,mass diffusion and electron mass transfer.Subsequently,a series of modulation methods and relevant works are discussed in detail from the three improvement directions of‘exposing more active sites,promoting mass diffusion and accelerating electron transfer’.Definitively,we provide farsighted insights into the understanding and research of three-phase interfaces in the future and point out the possible development direction of future regulatory methods,hoping that this review can broaden the future applications of the three-phase interface,including but not limited to gas-involved electrochemical reactions.展开更多
Accurate characterization of fluid phase behavior is an important aspect of CO_(2) enhanced shale oil recovery.So far,however,there has been little discussion about the nanopore confinement effect,including adsorption...Accurate characterization of fluid phase behavior is an important aspect of CO_(2) enhanced shale oil recovery.So far,however,there has been little discussion about the nanopore confinement effect,including adsorption and capillarity on the phase equilibrium of water-oil-CO_(2) mixtures.In this study,an improved three-phase flash algorithm is proposed for calculating the phase behavior of water-oil-gas mixture on the basis of an extended Young-Laplace equation and a newly developed fugacity calculation model.The fugacity model can consider the effect of water-oil-gas adsorption on phase equilibrium.A water-Bakken oil-CO_(2) mixture is utilized to verify the accuracy of the flash algorithm and investigate the confinement effect.Results show that the confinement effect promotes the transfer of all components in the vapor phase to other phases,while the transfer of water,CO_(2),and lighter hydrocarbons is more significant.This leads to a large decrease,a large increase,and a small increase in the mole fraction of the vapor,oleic,and aqueous phases,respectively.When the confinement effect is considered,the density difference of vaporoleic phases decreases,and the interfacial tension of vapor-oleic phases decreases;however,the density difference of vapor-aqueous phases increases,the interfacial tension of vapor-aqueous phases still decreases.展开更多
文摘The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct.
基金supported by the National Natural Science Foundation of China(Grant No.51977046)Wuxi University Research Start-up Fund for Introduced Talent(2022r021).
文摘The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.
基金supported by the National Natural Science Foundation of China(No.62271109)。
文摘In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperature swing can be equivalent to reducing maximum instantaneous phase copper loss in this paper.First,a two-level optimization aiming at minimizing maximum instantaneous phase copper loss at each electrical angle is proposed.Then,the optimization is transformed to a singlelevel optimization by introducing the auxiliary variable for easy solving.Considering that singleobjective optimization trades a great total copper loss for a small reduction of maximum phase copper loss,the optimization considering both instantaneous total copper loss and maximum phase copper loss is proposed,which has the same performance of temperature swing reduction but with lower total loss.In this way,the proposed control scheme can reduce maximum junction temperature by 11%.Both simulation and experimental results are presented to prove the effectiveness and superiority of the proposed control scheme for low-frequency temperature swing reduction.
基金the Natural Science Foundation of Fujian,China(No.2021J01633).
文摘This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.
基金financial support of National Key Research and Development Program of China(Grant No.2022YFB04200302)joint funds of National Natural Science Foundation of China(Grant No.62104115)+5 种基金National Natural Science Foundation of China(Grant No.U21A2072)Overseas Expertise Introduction Project for Discipline Innovation of Higher Education of China(Grant No.B16027)Key R&D Program of Hebei Province(No.19214301D)Yunnan Provincial Science and Technology Project at Southwest United Graduate School(No.202302A0370009)Haihe Laboratory of Sustainable Chemical TransformationsFundamental Research Funds for the Central Universities,Nankai University。
文摘The tensile strain in inorganic perovskite films induced by thermal annealing is one of the primary factors contributing to the inefficiency and instability of inorganic perovskite solar cells(IPSCs),which reduces the defect formation energy.Here,a flexible molecule 5-maleimidovaleric acid(5-MVA)was introduced as a strain buffer to release the residual strain of CsPbI_(2.85)Br_(0.15)perovskite.Maleic anhydride and carboxyl groups in 5-MVA interact strongly with the uncoordinated Pb^(2+)through Lewis acid-base reaction,thus tightly“pull”the perovskite lattice.The in-between soft carbon chain increased the structural flexibility of CsPbI_(2.85)Br_(0.15)perovskite materials,which effectively relieved the intrinsic internal strain of CsPbI_(2.85)Br_(0.15),resisted the corrosion of external strain,and also reduced the formation of defects such as VIand Pb0.In addition,the introduction of 5-MVA improved crystal quality,passivated residual defects,and narrowed energy level barriers.Eventually,power conversion efficiency(PCE)of NiOxbased inverted IPSCs increased from 19.25%to 20.82%with the open-circuit voltage enhanced from 1.164 V to 1.230 V.The release of strain also improved the stability of CsPbI_(2.85)Br_(0.15)perovskite films and devices.
文摘A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.
文摘The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.
文摘For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.
文摘DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.
文摘A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.
文摘Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.
文摘Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width modulation (SPWM) inverters with low harmonyic content in theory.The THD value would be increased by switching time delay of power devices and control circuit. A new control coecuit with delay time compensation is presented in this paper. With this control scheme, the output of the inverter could be basically identified with the theory given.Test results of experimental circuit verify that the control circuit presented in this paper is feasible. The THD of the inverter output voltage could be reduced to a certain extent by this method.
基金supported by the National Natural Science Foundation of China(21872040,22162004)the Hundred Talents Program of Guangxi Universities,the Excellent Scholars and Innovation Team of Guangxi Universities+1 种基金the Innovation Project of Guangxi Graduate Education(YCBZ2021011)the High-performance Computing Platform of Guangxi University.
文摘Constructing heterojunction is an effective strategy to develop high-performance non-preciousmetal-based catalysts for electrochemical water splitting(WS).Herein,we design and prepare an N-doped-carbon-encapsulated Ni/MoO_(2) nano-needle with three-phase heterojunction(Ni/MoO_(2)@CN)for accelerating the WS under industrial alkaline condition.Density functional theory calculations reveal that the electrons are redistributed at the three-phase heterojunction interface,which optimizes the adsorption energy of H-and O-containing intermediates to obtain the best ΔG_(H*) for hydrogen evolution reaction(HER)and decrease the ΔG value of ratedetermining step for oxygen evolution reaction(OER),thus enhancing the HER/OER catalytic activity.Electrochemical results confirm that Ni/MoO_(2)@CN exhibits good activity for HER(ƞ_(-10)=33 mV,ƞ_(-1000)=267 mV)and OER(ƞ_(10)=250 mV,ƞ_(1000)=420 mV).It shows a low potential of 1.86 V at 1000 mA cm^(−2) for WS in 6.0 M KOH solution at 60℃ and can steadily operate for 330 h.This good HER/OER performance can be attributed to the three-phase heterojunction with high intrinsic activity and the self-supporting nano-needle with more active sites,faster mass diffusion,and bubbles release.This work provides a unique idea for designing high efficiency catalytic materials for WS.
基金Project supported by the National Natural Science Foundation of China(Grant No.51107016)the National Basic Research Program of China(Grant No.2013CB035605)the Postdoctoral Science Research Developmental Foundation of Heilongjiang Province,China(Grant No.LHB-Q12086)
文摘Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.
文摘A novel electric vehicle (EV) induction motor (IM) controller based on voltage-fed inverter is presented. It is shown that the proposed adaptive control algorithm effectively both simplifies the structure and expands the capacity of controller. The relationship between stator's voltage and that of current under rotor's flux-oriented-coordinates is first introduced, and then the structure of vector control is analyzed, in which voltage compensation is inducted as the core feedback procedure. Experiments prove that, together with a facility for realization, a smooth transition, a prompt torque response and small concussion are gained. Extensive research conducted by varying parameters that result in practical ripple is proposed in conclusion.
基金This work was supported by the National Basic Research Program of China (2005CB221205)
文摘A three-phase reactor mathematical model was set up to simulate and design a three-phase bubble column reactor for direct synthesis of dimethyl ether (DME) from syngas, considering both the influence of part inert carrier backmixing on transfer and the influence of catalyst grain sedimentation on reaction. On the basis of this model, the influences of the size and reaction conditions of a 100000 t/a DME reactor on capacity were investigated. The optimized size of the 10000 t/a DME synthesis reactor was proposed as follows: diameter 3.2 m, height 20 m, built-in 400 tube heat exchanger (Ф 38×2 mm), and inert heat carrier paraffin oil 68 t and catalyst 34.46 t. Reaction temperature and pressure were important factors influencing the reaction conversion for different size reactors. Under the condition of uniform catalyst concentration distribution, higher pressure and temperature were proposed to achieve a higher production capacity of DME. The best ratio of fresh syngas for DME synthesis was 2.04.
基金Project supported by the Open Fund of Key Laboratory of Complex Electromagnetic Environment Science and Technology,China Academy of Engineering Physics(Grant No.2015-0214.XY.K)
文摘The thermal failure induced by high power microwave(HPM) in a complementary metal oxide semiconductor(CMOS) inverter is investigated and its dependence on microwave parameters is discussed in detail. An analytical model of the temperature distribution is established and the relationships between hotspot temperature and pulse width and between hotspot temperature and frequency are predicted, which reveals a more severe rise in temperature under the influence of microwave with longer width and lower frequency. The temperature variation mechanism and the theoretical temperature model are validated and explained by the simulation. Furthermore, variation trend of damage threshold with microwave parameters is derived theoretically, and the conclusions are consistent with simulation results and reported data.
文摘Battery energy storage systems,fuel cells,and photovoltaic generators are being adopted in distribution networks to achieve CO;emission reduction.These power sources require inverters to connect to AC networks.However,sub-networks,such as a microgrids containing inverter power sources,may be disconnected from the utility network and operated in a standalone mode during extended blackouts.This study focuses on a standalone microgrid supplied by inverter power sources without a synchronous generator and proposes a new microgrid inverter control.In this inverter control,a single grid forming inverter is operated as a master power source to determine frequency and voltage,and other inverters,called grid following inverters,are operated as subordinate power sources with active and reactive power control.The necessary functions in the energy management system are examined,and the coordinated operation of all inverters in the microgrid is demonstrated via simulation.
基金supported by the National Natural Science Foundation of China(U21A20332,52103226,52202275,52203314,and 12204253)the Distinguished Young Scholars Fund of Jiangsu Province(BK20220061)the Fellowship of China Postdoctoral Science Foundation(2021 M702382)。
文摘As an alternative to conventional energy conversion and storage reactions,gas-involved electrochemical reactions,including the carbon dioxide reduction reaction(CO_(2)RR),nitrogen reduction reaction(NRR)and hydrogen evolution reaction(HER),have become an emerging research direction and have gained increasing attention due to their advantages of environmental friendliness and sustainability.Various studies have been designed to accelerate sluggish kinetics but with limited results.Most of them promote the reaction by modulating the intrinsic properties of the catalyst,ignoring the synergistic effect of the reaction as a whole.Due to the introduction of gas,traditional liquid-solid two-phase reactions are no longer applicable to future research.Since gas-involved electrochemical reactions mostly occur at the junctions of gaseous reactants,liquid electrolytes and solid catalysts,the focus of future research on reaction kinetics should gradually shift to three-phase reaction interfaces.In this review,we briefly introduce the formation and constraints of the three-phase interface and propose three criteria to judge its merit,namely,the active site,mass diffusion and electron mass transfer.Subsequently,a series of modulation methods and relevant works are discussed in detail from the three improvement directions of‘exposing more active sites,promoting mass diffusion and accelerating electron transfer’.Definitively,we provide farsighted insights into the understanding and research of three-phase interfaces in the future and point out the possible development direction of future regulatory methods,hoping that this review can broaden the future applications of the three-phase interface,including but not limited to gas-involved electrochemical reactions.
基金The financial support from National Natural Science Foundation of China(52074319,U19B6003-02)Strategic Cooperation Technology Project of CNPC(ZLZX 2020-01-08)。
文摘Accurate characterization of fluid phase behavior is an important aspect of CO_(2) enhanced shale oil recovery.So far,however,there has been little discussion about the nanopore confinement effect,including adsorption and capillarity on the phase equilibrium of water-oil-CO_(2) mixtures.In this study,an improved three-phase flash algorithm is proposed for calculating the phase behavior of water-oil-gas mixture on the basis of an extended Young-Laplace equation and a newly developed fugacity calculation model.The fugacity model can consider the effect of water-oil-gas adsorption on phase equilibrium.A water-Bakken oil-CO_(2) mixture is utilized to verify the accuracy of the flash algorithm and investigate the confinement effect.Results show that the confinement effect promotes the transfer of all components in the vapor phase to other phases,while the transfer of water,CO_(2),and lighter hydrocarbons is more significant.This leads to a large decrease,a large increase,and a small increase in the mole fraction of the vapor,oleic,and aqueous phases,respectively.When the confinement effect is considered,the density difference of vaporoleic phases decreases,and the interfacial tension of vapor-oleic phases decreases;however,the density difference of vapor-aqueous phases increases,the interfacial tension of vapor-aqueous phases still decreases.