Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure o...Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.展开更多
Test points selection for integer-coded fault wise table is a discrete optimization problem. The global minimum set of test points can only be guaranteed by an exhaustive search which is eompurationally expensive. In ...Test points selection for integer-coded fault wise table is a discrete optimization problem. The global minimum set of test points can only be guaranteed by an exhaustive search which is eompurationally expensive. In this paper, this problem is formulated as a heuristic depth-first graph search problem at first. The graph node expanding method and rules are given. Then, rollout strategies are applied, which can be combined with the heuristic graph search algorithms, in a computationally more efficient manner than the optimal strategies, to obtain solutions superior to those using the greedy heuristic algorithms. The proposed rollout-based test points selection algorithm is illustrated and tested using an analog circuit and a set of simulated integer-coded fault wise tables. Computa- tional results are shown, which suggest that the rollout strategy policies are significantly better than other strategies.展开更多
Test points selection for integer-coded fault wise table is a discrete optimization problem. On one hand, traditional exhaustive search method is computationally expensive. On the other hand, the space complexity of t...Test points selection for integer-coded fault wise table is a discrete optimization problem. On one hand, traditional exhaustive search method is computationally expensive. On the other hand, the space complexity of traditional exhaustive is low. A tradeoff method between the high time complexity and low space complexity is proposed. At first, a new fault-pair table is constructed based on the integer-coded fault wise table. The fault-pair table consists of two columns: one column represents fault pair and the other represents test points set that can distinguish the corresponding faults. Then, the rows are arranged in ascending order according to the cardinality of corresponding test points set. Thirdly, test points in the top rows are selected one by one until all fault pair are isolated. During the test points selection process, the rows that contain selected test points are deleted and then the dimension of fault-pair table decreases gradually. The proposed test points selection algorithm is illustrated and tested using an integercoded fault wise table derived from a real analog circuit. Computational results suggest show policies are better than the exhaustive strategy.展开更多
为研究颗粒阻尼器布置方案对多层结构减震性能的影响,制作了缩尺比为1/5的三层钢框架模型结构,进行了5条天然波下的地震模拟振动台试验,研究并联式单向单颗粒阻尼器(Parallel Single-dimensional Single Particle Damper,PSSPD)的减震...为研究颗粒阻尼器布置方案对多层结构减震性能的影响,制作了缩尺比为1/5的三层钢框架模型结构,进行了5条天然波下的地震模拟振动台试验,研究并联式单向单颗粒阻尼器(Parallel Single-dimensional Single Particle Damper,PSSPD)的减震控制效果。基于试验获得的模型自振频率、阻尼比等动力特性设计3种PSSPD布置方案,分析不同布置方案下模型结构的试验现象及位移和加速度响应。试验结果表明:PSSPD对结构响应峰值减震率可达到43.43%,均方根减震率可达到38.18%,其对多层结构具有良好的减震控制效果;PSSPD对结构均方根的平均减震效果要优于对峰值的平均减震效果;PSSPD布置方案对其减震效果影响显著,且其减震性能与本身参数、受控结构振动特性、地震动参数之间的耦合关系复杂。最后,建立PSSPD在任意布置方案下受控结构的力学模型,提出其数值分析流程。数值计算结果和试验结果在位移峰值及均方根方面具有良好的吻合度。展开更多
Components of mechanical product are assembled by structural joints,such as bolting,riveting,welding,etc.Structural joints introduce nonlinearity to some engineering structures,and the nonlinearity need to be modeled ...Components of mechanical product are assembled by structural joints,such as bolting,riveting,welding,etc.Structural joints introduce nonlinearity to some engineering structures,and the nonlinearity need to be modeled precisely.To meet serious quality requirements,it is necessary to detect and identify nonlinearity of mechanical products for structural optimization.Modal test to acquire a dynamic response has been applied for decades,which provides reliable results for finite element(FE)model updating.Here response control vibration test for identification of nonlinearity is presented.A nonlinear system can be regarded as linearity for particular steady state response,and classical linear analysis tool is applicable to extract modal data for particular response.First,its applicability is illustrated by some numerical simulations.Subsequently,it is implemented on experimental setup with structural joints by shaking table.The stiffness and damping function dependent of relative displacement are fitted to describe its inherent nonlinearity.The spring and damping forces are identified by harmonic balance method(HBM)to predict output response.Based on the identified results,the procedure is recommended that it allows a reliable measurement of nonlinearity with a certain accuracy.展开更多
基金supported by the Jiangsu Natural Science Foundation of China(Grant No.BK2012477)the Science Research Foundation of Nanjing Institute of Technology(CKJA201505,JCYJ201618)
文摘Adopting a soft site model built on soft interlayer soil foundation,a shaking table test for soft interlayer soil-isolated structure interaction is conducted to investigate the seismic response of isolated structure on soft site,and analyze its isolation effect.Test results show that the test can reflect the earthquake response characteristics of isolated structure on soft site.It is on soft site that the dynamic characteristics of isolated structure,acceleration magnification factor(AMF)of isolated structure and isolation efficiency of the isolation layer differ from those on rigid foundation with an soil-structure interaction(SSI)effect,represented by the reduction in fundamental vibration frequency of isolated structure and the increase of damping ratio with changes of the SSI effect.SSI can either increase or decrease AMF of isolated structure on soft site,depending on the characteristics of earthquake motion input.Furthermore,the isolation efficiency of isolation layer on soft site is decreased with the SSI effect,which is related to the peak ground acceleration(PGA)and the characteristics of earthquake motion input.
基金supported by Commission of Science Technology and Industry for National Defence of China under Grant No.A1420061264National Natural Science Foundation of China under Grant No.60934002General Armament Department under Grand No.51317040102)
文摘Test points selection for integer-coded fault wise table is a discrete optimization problem. The global minimum set of test points can only be guaranteed by an exhaustive search which is eompurationally expensive. In this paper, this problem is formulated as a heuristic depth-first graph search problem at first. The graph node expanding method and rules are given. Then, rollout strategies are applied, which can be combined with the heuristic graph search algorithms, in a computationally more efficient manner than the optimal strategies, to obtain solutions superior to those using the greedy heuristic algorithms. The proposed rollout-based test points selection algorithm is illustrated and tested using an analog circuit and a set of simulated integer-coded fault wise tables. Computa- tional results are shown, which suggest that the rollout strategy policies are significantly better than other strategies.
基金supported by National Natural Science Foundation of China under Grant No.60934002General Armament Department under Grant No.51317040102
文摘Test points selection for integer-coded fault wise table is a discrete optimization problem. On one hand, traditional exhaustive search method is computationally expensive. On the other hand, the space complexity of traditional exhaustive is low. A tradeoff method between the high time complexity and low space complexity is proposed. At first, a new fault-pair table is constructed based on the integer-coded fault wise table. The fault-pair table consists of two columns: one column represents fault pair and the other represents test points set that can distinguish the corresponding faults. Then, the rows are arranged in ascending order according to the cardinality of corresponding test points set. Thirdly, test points in the top rows are selected one by one until all fault pair are isolated. During the test points selection process, the rows that contain selected test points are deleted and then the dimension of fault-pair table decreases gradually. The proposed test points selection algorithm is illustrated and tested using an integercoded fault wise table derived from a real analog circuit. Computational results suggest show policies are better than the exhaustive strategy.
文摘为研究颗粒阻尼器布置方案对多层结构减震性能的影响,制作了缩尺比为1/5的三层钢框架模型结构,进行了5条天然波下的地震模拟振动台试验,研究并联式单向单颗粒阻尼器(Parallel Single-dimensional Single Particle Damper,PSSPD)的减震控制效果。基于试验获得的模型自振频率、阻尼比等动力特性设计3种PSSPD布置方案,分析不同布置方案下模型结构的试验现象及位移和加速度响应。试验结果表明:PSSPD对结构响应峰值减震率可达到43.43%,均方根减震率可达到38.18%,其对多层结构具有良好的减震控制效果;PSSPD对结构均方根的平均减震效果要优于对峰值的平均减震效果;PSSPD布置方案对其减震效果影响显著,且其减震性能与本身参数、受控结构振动特性、地震动参数之间的耦合关系复杂。最后,建立PSSPD在任意布置方案下受控结构的力学模型,提出其数值分析流程。数值计算结果和试验结果在位移峰值及均方根方面具有良好的吻合度。
文摘Components of mechanical product are assembled by structural joints,such as bolting,riveting,welding,etc.Structural joints introduce nonlinearity to some engineering structures,and the nonlinearity need to be modeled precisely.To meet serious quality requirements,it is necessary to detect and identify nonlinearity of mechanical products for structural optimization.Modal test to acquire a dynamic response has been applied for decades,which provides reliable results for finite element(FE)model updating.Here response control vibration test for identification of nonlinearity is presented.A nonlinear system can be regarded as linearity for particular steady state response,and classical linear analysis tool is applicable to extract modal data for particular response.First,its applicability is illustrated by some numerical simulations.Subsequently,it is implemented on experimental setup with structural joints by shaking table.The stiffness and damping function dependent of relative displacement are fitted to describe its inherent nonlinearity.The spring and damping forces are identified by harmonic balance method(HBM)to predict output response.Based on the identified results,the procedure is recommended that it allows a reliable measurement of nonlinearity with a certain accuracy.