Wet bulb globe temperature(WBGT)is a comprehensive index obtained mainly from three parameters:black globe temperature(Tg),wet bulb temperature(Tw),and dry bulb temperature(Ta).While in field observation and numerical...Wet bulb globe temperature(WBGT)is a comprehensive index obtained mainly from three parameters:black globe temperature(Tg),wet bulb temperature(Tw),and dry bulb temperature(Ta).While in field observation and numerical simulation,black globe temperature and wet bulb temperature were not easy to obtain,so WBGT was difficult to measure and calculate directly.In order to solve this problem,air dry bulb temperature,wet bulb temperature,globe temperature,relative humidity,mean air velocity,solar radiation and wet bulb globe temperature were collected during the summer(July)in Guangzhou.Correlation analysis and regression analysis were used to get a simplified method to calculate WBGT.The results showed that dry bulb temperature,relative humidity,solar radiation and WBGT were interrelated to some extent.These three parameters could be used in the simplified method to predict WBGT,and the linear correlation and precision of this model were high.In addition,we used the measured data to verify the simplified method,and the results showed that the error of the calculated value and the measured value was all below 5%,which means the simplified calculating method is feasible and can be used in field observation and simulation research of urban thermal environment.展开更多
Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity ind...Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity independent control air-conditioning unit was developed for single residential house by utilizing multi-variable technology.First,the supply air temperature was studied to determine the proper supply air flow rate for the humidity control.Then,the energy consumption of different temperature-humidity independent control systems was studied.The analysis indicates that unity evaporating temperature can be used to handle the moisture load and sensible heat load in two evaporators.So the unit scheme was put forward.Two evaporators were used to produce medium temperature water and dry air separately,and electric expansion valves were used to control the refrigerant distribution between the two evaporators.Then,experimental work was carried out to investigate the influence of compressor frequency,refrigerant distribution on the dehumidification capacity,energy efficiency and refrigeration capacity.In the end,the paper concludes that both compressor frequency and refrigerant distribution can control the dehumidification capacity,but the former influences the EER more than the latter,while the latter influences the refrigeration capacity more than the former.We can find a proper running point at certain sensible and latent cooling load by adjusting both compressor frequency and electric expansion valve.The energy consumption of this kind of unit was estimated and compared with present room air conditioners,which shows that it can save about 41% cooling energy consumption.展开更多
基金Supported by the National Natural Science Foundation of China(50538040,50720165805,50808083)the 111 project(111-2-13)State Key Laboratory of Subtropical Building(2008ZB14)
文摘Wet bulb globe temperature(WBGT)is a comprehensive index obtained mainly from three parameters:black globe temperature(Tg),wet bulb temperature(Tw),and dry bulb temperature(Ta).While in field observation and numerical simulation,black globe temperature and wet bulb temperature were not easy to obtain,so WBGT was difficult to measure and calculate directly.In order to solve this problem,air dry bulb temperature,wet bulb temperature,globe temperature,relative humidity,mean air velocity,solar radiation and wet bulb globe temperature were collected during the summer(July)in Guangzhou.Correlation analysis and regression analysis were used to get a simplified method to calculate WBGT.The results showed that dry bulb temperature,relative humidity,solar radiation and WBGT were interrelated to some extent.These three parameters could be used in the simplified method to predict WBGT,and the linear correlation and precision of this model were high.In addition,we used the measured data to verify the simplified method,and the results showed that the error of the calculated value and the measured value was all below 5%,which means the simplified calculating method is feasible and can be used in field observation and simulation research of urban thermal environment.
基金Supported by Research Fund of the 11th 5year Sci Tech National Support Project
文摘Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity independent control air-conditioning unit was developed for single residential house by utilizing multi-variable technology.First,the supply air temperature was studied to determine the proper supply air flow rate for the humidity control.Then,the energy consumption of different temperature-humidity independent control systems was studied.The analysis indicates that unity evaporating temperature can be used to handle the moisture load and sensible heat load in two evaporators.So the unit scheme was put forward.Two evaporators were used to produce medium temperature water and dry air separately,and electric expansion valves were used to control the refrigerant distribution between the two evaporators.Then,experimental work was carried out to investigate the influence of compressor frequency,refrigerant distribution on the dehumidification capacity,energy efficiency and refrigeration capacity.In the end,the paper concludes that both compressor frequency and refrigerant distribution can control the dehumidification capacity,but the former influences the EER more than the latter,while the latter influences the refrigeration capacity more than the former.We can find a proper running point at certain sensible and latent cooling load by adjusting both compressor frequency and electric expansion valve.The energy consumption of this kind of unit was estimated and compared with present room air conditioners,which shows that it can save about 41% cooling energy consumption.