A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is t...A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.展开更多
There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw...There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.展开更多
在中长期水火发电调度中考虑检修计划的影响是目前中长期水火发电调度面临的难题。利用现代整数代数建模技术,建立发电计划和检修计划协调优化的多场景调度模型。在该模型中,鉴于设备检修计划的连续性,在预测场景树的基础上,将场景...在中长期水火发电调度中考虑检修计划的影响是目前中长期水火发电调度面临的难题。利用现代整数代数建模技术,建立发电计划和检修计划协调优化的多场景调度模型。在该模型中,鉴于设备检修计划的连续性,在预测场景树的基础上,将场景节点划分成不同的场景,通过节点和场景关联矩阵,实现多场景下设备检修模型的构建。同时,鉴于中长期调度计划中发电计划和检修计划对时段间隔要求的不同,分别设置电量相关节点和电力相关节点,实现中长期发电计划和检修计划的协调。上述模型是一个大规模混合整数线性规划(mixed integer linear programming,MILP)问题,采用商用MILP求解器进行求解。大规模实际水火电系统的实例分析结果表明,所提模型和方法是可行、有效的。展开更多
Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V...Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.展开更多
Subsurface cavities are very susceptible subsurface locations for down-lifting of a dam construction.In order to detect the low-density zones of a power plant a micro-gravity survey was conducted in a site considered ...Subsurface cavities are very susceptible subsurface locations for down-lifting of a dam construction.In order to detect the low-density zones of a power plant a micro-gravity survey was conducted in a site considered for construction of a power plant site in Iran.First we gain the residual anomalies through bouger anomalies and then we design an Artificial Neural Network(ANN)which is trained by a set of training data.The ANN was tested for both synthetic and real data.For real data some suitable features are derivate from residual anomalies and applied to展开更多
The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using th...The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using the autoclam permeability system. The air permeability, sorptivity and water permeability indexes of No.1 PCCB are smaller than or equal to 0.11 ln(102 Pa)/min, 0.98×10 ^7 m3/minl/2 and 1.93×10 ^7 m3/min1/2, respectively, and the air permeability, sorptivity and water permeability indexes of No.2 PCCB are smaller than or equal to 0.17 In(102 Pa)/min, 1.6×10 ^7 m3/min1/2 and 4.43 ×10 ^7 m3/min1/2, respectively. Based on the criteria for evaluating the protective quality of concrete structures in terms of their permeability and sorptivity properties, proposed by the research organization of the autoclam permeability system, the protective quality of No. 1 PCCB is still in very good grade and that of No.2 PCCB is not in very good grade but in good grade, and the in-service inspection of the protective quality of No.2 PCCB should be strengthened in the future.展开更多
The carbon sorbent traps method was used to monitor the mercury content and speciation underhigh-temperature and high-ash content conditions that are beyond the allowable conditions of the EPAMethod 30B,to extend its ...The carbon sorbent traps method was used to monitor the mercury content and speciation underhigh-temperature and high-ash content conditions that are beyond the allowable conditions of the EPAMethod 30B,to extend its application range.The results show that,when measuring the total mercury con-centration in flue gas,this method can be applied to the occasions of high dust concentration(e.g.beforethe WFGD system),with the error caused by dust lower than 1%,if keeping the flow rate at a lower leveland employing dustproof cover.But this method is not suitable to the conditions with extreme high dustcontent.By applying air-cooled casing and controlling the sampling gun's insert depth,the temperature ofcarbon traps can be kept within a suitable range.Thus,the measurement accuracy of mercury concentrationbefore air preheater can be ensured.For the chimney inlet and other areas with low dust concentration,theproportion of Hg°measured by the 30B method is in accordance with the Hg-CEMS after the WFGD sys-tem,while after the CFB-FGD system,the proportion of Hg°measured by the 30B method is slightly lowerthan that by the Hg-CEMS method.For locations with high dust concentration,the proportion of Hg°measured by the 30B method may be much lower than the true value.展开更多
A type of plant audio generator was introduced in the paper including its circuit configuration, principle of working and used to deal with spinach in order to discuss effect of audio frequency on plant growth.
An optimal method for prediction and adjustment on byproduct gasholder level and self-provided power plant gas supply was proposed.This work raises the HP-ENN-LSSVM model based on the Hodrick-Prescott filter,Elman neu...An optimal method for prediction and adjustment on byproduct gasholder level and self-provided power plant gas supply was proposed.This work raises the HP-ENN-LSSVM model based on the Hodrick-Prescott filter,Elman neural network and least squares support vector machines.Then,according to the prediction,the optimal adjustment process came up by a novel reasoning method to sustain the gasholder within safety zone and the self-provided power plant boilers in economic operation,and prevent unfavorable byproduct gas emission and equipment trip as well.The experiments using the practical production data show that the proposed method achieves high accurate predictions and the optimal byproduct gas distribution,which provides a remarkable guidance for reasonable scheduling of byproduct gas.展开更多
The most dangerous places in ships are their power plants. Particularly, they are very unsafe for operators carrying out various necessary operation and maintenance activities. For this reason, ship machinery should b...The most dangerous places in ships are their power plants. Particularly, they are very unsafe for operators carrying out various necessary operation and maintenance activities. For this reason, ship machinery should be designed to ensure the maximum safety for its operators. It is a very difficult task. Therefore, it could not be solved by means of conventional design methods, which are used for design of uncomplicated technical equipment. One of the possible ways of solving this problem is to provide appropriate tools, which allow us to take the operator's safety into account during a design process, especially at its early stages. A computer-aided system supporting design of safe ship power plants could be such a tool. This paper deals with developing process of a prototype of the computer-aided system for hazard zone identification in ship power plants.展开更多
基金Project(217/s/458)supported by Azarbaijan Shahid Madani University,Iran
文摘A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.
基金Key Project of National Natural Science Foundation of China(52237008)Beijing Municipal Education Commission Research Program Funding Project(KM202111232022)。
文摘There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.
文摘在中长期水火发电调度中考虑检修计划的影响是目前中长期水火发电调度面临的难题。利用现代整数代数建模技术,建立发电计划和检修计划协调优化的多场景调度模型。在该模型中,鉴于设备检修计划的连续性,在预测场景树的基础上,将场景节点划分成不同的场景,通过节点和场景关联矩阵,实现多场景下设备检修模型的构建。同时,鉴于中长期调度计划中发电计划和检修计划对时段间隔要求的不同,分别设置电量相关节点和电力相关节点,实现中长期发电计划和检修计划的协调。上述模型是一个大规模混合整数线性规划(mixed integer linear programming,MILP)问题,采用商用MILP求解器进行求解。大规模实际水火电系统的实例分析结果表明,所提模型和方法是可行、有效的。
基金the output of a research project (Title: Application of Doubly Fed Asynchronous machine in Pumped Storage Hydropower Plant in Generate Mode, supported by Islamic Azad University South Tehran Branch)
文摘Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux.
文摘Subsurface cavities are very susceptible subsurface locations for down-lifting of a dam construction.In order to detect the low-density zones of a power plant a micro-gravity survey was conducted in a site considered for construction of a power plant site in Iran.First we gain the residual anomalies through bouger anomalies and then we design an Artificial Neural Network(ANN)which is trained by a set of training data.The ANN was tested for both synthetic and real data.For real data some suitable features are derivate from residual anomalies and applied to
基金Project(20050487017) supported by the Specialized Research Fund for the Doctoral Program of Higher Education of ChinaProject (2009567) supported by China National Nuclear Corporation
文摘The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using the autoclam permeability system. The air permeability, sorptivity and water permeability indexes of No.1 PCCB are smaller than or equal to 0.11 ln(102 Pa)/min, 0.98×10 ^7 m3/minl/2 and 1.93×10 ^7 m3/min1/2, respectively, and the air permeability, sorptivity and water permeability indexes of No.2 PCCB are smaller than or equal to 0.17 In(102 Pa)/min, 1.6×10 ^7 m3/min1/2 and 4.43 ×10 ^7 m3/min1/2, respectively. Based on the criteria for evaluating the protective quality of concrete structures in terms of their permeability and sorptivity properties, proposed by the research organization of the autoclam permeability system, the protective quality of No. 1 PCCB is still in very good grade and that of No.2 PCCB is not in very good grade but in good grade, and the in-service inspection of the protective quality of No.2 PCCB should be strengthened in the future.
基金The Science and Technology Project in China Huaneng Group:“Mercury Control Technology R&D Laboratory Construction”
文摘The carbon sorbent traps method was used to monitor the mercury content and speciation underhigh-temperature and high-ash content conditions that are beyond the allowable conditions of the EPAMethod 30B,to extend its application range.The results show that,when measuring the total mercury con-centration in flue gas,this method can be applied to the occasions of high dust concentration(e.g.beforethe WFGD system),with the error caused by dust lower than 1%,if keeping the flow rate at a lower leveland employing dustproof cover.But this method is not suitable to the conditions with extreme high dustcontent.By applying air-cooled casing and controlling the sampling gun's insert depth,the temperature ofcarbon traps can be kept within a suitable range.Thus,the measurement accuracy of mercury concentrationbefore air preheater can be ensured.For the chimney inlet and other areas with low dust concentration,theproportion of Hg°measured by the 30B method is in accordance with the Hg-CEMS after the WFGD sys-tem,while after the CFB-FGD system,the proportion of Hg°measured by the 30B method is slightly lowerthan that by the Hg-CEMS method.For locations with high dust concentration,the proportion of Hg°measured by the 30B method may be much lower than the true value.
文摘A type of plant audio generator was introduced in the paper including its circuit configuration, principle of working and used to deal with spinach in order to discuss effect of audio frequency on plant growth.
基金Project(51066002/E060701) supported by the National Natural Science Foundation of ChinaProject(U0937604) supported by the NSFC-Yunnan Joint Fund of China
文摘An optimal method for prediction and adjustment on byproduct gasholder level and self-provided power plant gas supply was proposed.This work raises the HP-ENN-LSSVM model based on the Hodrick-Prescott filter,Elman neural network and least squares support vector machines.Then,according to the prediction,the optimal adjustment process came up by a novel reasoning method to sustain the gasholder within safety zone and the self-provided power plant boilers in economic operation,and prevent unfavorable byproduct gas emission and equipment trip as well.The experiments using the practical production data show that the proposed method achieves high accurate predictions and the optimal byproduct gas distribution,which provides a remarkable guidance for reasonable scheduling of byproduct gas.
文摘The most dangerous places in ships are their power plants. Particularly, they are very unsafe for operators carrying out various necessary operation and maintenance activities. For this reason, ship machinery should be designed to ensure the maximum safety for its operators. It is a very difficult task. Therefore, it could not be solved by means of conventional design methods, which are used for design of uncomplicated technical equipment. One of the possible ways of solving this problem is to provide appropriate tools, which allow us to take the operator's safety into account during a design process, especially at its early stages. A computer-aided system supporting design of safe ship power plants could be such a tool. This paper deals with developing process of a prototype of the computer-aided system for hazard zone identification in ship power plants.