期刊文献+
共找到19,926篇文章
< 1 2 250 >
每页显示 20 50 100
Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag 被引量:1
1
作者 GE Lian-feng1,2,LEI Ming3,CHEN You-ming1,2(1.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China 2.Key Laboratory of Building Safety and Energy Efficiency,MOE,China (3.Aviation Theory Department,Aviation University of Air Force,Changchun,Jilin 130022,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期79-82,共4页
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo... Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant. 展开更多
关键词 building construction theRMAL LAG system capacity design WEAtheR data AIR-CONDITIONING
在线阅读 下载PDF
Role of outdoor trees on pedestrian wind and thermal conditions around a pre-education building for sustainable energy management
2
作者 LI Xiao-jie TANG Hui-li 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第6期2039-2053,共15页
Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian... Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian-level wind velocity and thermal condition.In this study,a numerical investigation is employed to assess the role of trees planted in the windward direction of the building complex on the thermal and pedestrian wind velocity conditions around/inside a pre-education building located in the center of the complex.Compared to the previous studies(which considered only outside buildings),this work considers the effects of trees on microclimate change both inside/outside buildings.Effects of different parameters including the leaf area density and number of trees,number of rows,far-field velocity magnitude,and thermal condition around the main building are assessed.The results show that the flow velocity in the spacing between the first-row buildings is reduced by 30%-40% when the one-row trees with 2 m height are planted 15 m farther than the buildings.Furthermore,two rows of trees are more effective in higher velocities and reduce the maximum velocity by about 50%.The investigation shows that trees also could reduce the temperature by about 1℃around the building. 展开更多
关键词 sustainable management energy trees urban area thermal condition building
在线阅读 下载PDF
Fuzzy synthetic assessment of building fire safety system 被引量:7
3
作者 YANG Gao-shang PENG Li-min 《Journal of Central South University of Technology》 2005年第z1期194-198,共5页
A multistage assessment index set is chosen based on the analysis of building fire safety system, whereby the weight of each index is determined through an analy tie.hierarchy process; a fuzzy synthetic assessment mod... A multistage assessment index set is chosen based on the analysis of building fire safety system, whereby the weight of each index is determined through an analy tie.hierarchy process; a fuzzy synthetic assessment model for the building fire safety system is constructed, and the quantified result was obtained by using hierarchy parameter judgment. This fuzzy synthetic assessment method can quantify assessment result of the building fire safety system, so thatthe fire precautions may be accurately adopted, and the serious potential risk may be avoided. The application shows that this method possesses both objectivity and feasibility. 展开更多
关键词 building FIRE safety system ASSESSMENT index set fuzzy SYNtheTIC ASSESSMENT HIERARCHY PARAMETER JUDGMENT
在线阅读 下载PDF
Group Support Systems: Implications for Multi-Disciplinary Theory Building 被引量:1
4
作者 Leonard M. Jessup Joseph S. Valacich(College of Business Administration California State University, San Marcos 820 West Los Vallecitos Boulevard San Marcos, California 92069 (619) 752-4233) (Department of Decision and Information SystemsSchool of Busi 《决策与决策支持系统》 1996年第2期92-107,共16页
Group Support Systems:Implications for Multi-Disciplinary Theory BuildingLeonardM.Jessup;JosephS.Valacich(Co... Group Support Systems:Implications for Multi-Disciplinary Theory BuildingLeonardM.Jessup;JosephS.Valacich(CollegeofBusinessAd... 展开更多
关键词 Group Support systems Implications for Multi-Disciplinary theory building
在线阅读 下载PDF
Map Building for a Mobile Robot Based on Grey System Theory
5
作者 王卫华 席裕庚 陈卫东 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2003年第3期67-72,共6页
In this paper, a new method for mobile robot map building based on grey system theory is presented, by which interpretation and integration of sonar readings can be solved robustly and efficiently. The conception of &... In this paper, a new method for mobile robot map building based on grey system theory is presented, by which interpretation and integration of sonar readings can be solved robustly and efficiently. The conception of 'grey number is introduced to model and handle the uncertainty of sonar reading. A new data fusion approach based on grey system theory is proposed to construct environment model. Map building experiments are performed both on a platform of simulation and a real mobile robot. Experimental results show that our method is robust and accurate. 展开更多
关键词 Grey system theory UNCERTAINTY Map building Mobile robot.
在线阅读 下载PDF
A primary study of the acoustics of Chinese traditional theatrical buildings 被引量:3
6
作者 WANG Jiqing (Institute of Acoustics, Tongji University, Shanghai 200092, China ) 《声学技术》 CSCD 2003年第z1期2-5,共4页
The traditional performing arts and theatrical buildings in China can be traced back to a long history and were well developed during Song and Yuan Dynasties, 11th-14th centuries. Pavilion stage, opened on three sides... The traditional performing arts and theatrical buildings in China can be traced back to a long history and were well developed during Song and Yuan Dynasties, 11th-14th centuries. Pavilion stage, opened on three sides and thrusting into the audience area, was unique and the most popular form in the open-air theatres, the courtyard theatres, and the indoor theatres up to the present day. As the traditional Chinese opera is performed in an abstract way, no stage settings are required and used. Therefore, the pavilion stage including the flat or domed ceiling and the back wall is virtually functioned as a reflective shell, which increases the early reflections and also intensifies the sound in the audience area. Meanwhile, it provides sufficient self-support to the performers. Acoustical parameters including reverberation time RT, early decay time EDT, acoustic ratio C (50), strength index (loudness) G, and stage support factor ST1 were measured and reported on several traditional theatrical buildings. 展开更多
关键词 AUDITORIUM acoustics theatrical building ACOUSTICS of TRADITIONAL PERFORMANCE
在线阅读 下载PDF
Impact of light-weight external thermal insulation materials on building surrounding thermal environment in summer 被引量:6
7
作者 李楠 罗国志 +1 位作者 李百战 黄彦祺 《Journal of Central South University》 SCIE EI CAS 2012年第6期1639-1644,共6页
The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick... The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward. 展开更多
关键词 surface heat storage coefficient external thermal insulation building thermal environment building envelop
在线阅读 下载PDF
A case study of excessive vibrations inside buildings due to an underground railway:Experimental tests and theoretical analysis 被引量:7
8
作者 MING Xuan-hui ZHENG Jun-yuan +3 位作者 WANG Liu-chong ZHAO Cai-you WANG Ping YAO Li 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第1期313-330,共18页
Excessive vibrations inside buildings in the Lihu New Village caused by the Shenzhen Metro Line 2 underground railway were investigated by conducting analyses of the tunnel,the track irregularities,the stiffness of th... Excessive vibrations inside buildings in the Lihu New Village caused by the Shenzhen Metro Line 2 underground railway were investigated by conducting analyses of the tunnel,the track irregularities,the stiffness of the fastening system,and the vibrations of the track system and the building at different speeds.A numerical simulation based on the dynamic coupling theory of the vehicle-track system was used to verify the experimental results.Suitable countermeasures were investigated.The results show that rail corrugation is the primary reason for the excessive vibration,and an increase in the stiffness of the vertical fastening system is the secondary reason.The solution was to eliminate the rail corrugation using rail grinding and decrease the vertical stiffness by changing the fastening system.The results of this study provide references for solving vibration problems caused by rail lines. 展开更多
关键词 excessive vibration buildingS underground railway experimental investigation numerical simulation
在线阅读 下载PDF
Assessment of green roof performance for sustainable buildings under winter weather conditions 被引量:2
9
作者 J.Srebric 《Journal of Central South University》 SCIE EI CAS 2012年第3期639-644,共6页
A green roof is a specialized roof system that supports vegetation growth on rooftops.This technology is rapidly gaining popularity as a sustainable design option for buildings.In order to contribute to an understandi... A green roof is a specialized roof system that supports vegetation growth on rooftops.This technology is rapidly gaining popularity as a sustainable design option for buildings.In order to contribute to an understanding of green roof in regions with cold winters and snow,an on-site experimental investigation was present with a focus on the assessment of green roof performance during the winter.This field experiment took place on a six small buildings during the winter of 2010-2011.The work monitored three buildings with green roofs,two buildings with reference roofs and one building with a bare soil coverage for the roof.These six buildings were identically constructed and instrumented with sensor networks to provide heat flux data through the roofs.The 15 min averaged data were statistically analyzed for a week under the two separate periods,first without a snow cover and second with a snow cover.The results show that the roof type is a significant factor in affecting the thermal performance of these buildings.Most importantly,green roofs reduce heat flow through the roof and thus reduce the heating energy demand during the winter.However,the energy savings for buildings with the green roofs are reduced under snow conditions because the snow diminishes thermal resistance of the roof and increases the heat transfer process through the roofs. 展开更多
关键词 green roof energy savings building envelop sustainable buildings
在线阅读 下载PDF
Fuzzy-AHP-Based Comprehensive Evaluation on Facility Management System of High-Rise Office Buildings 被引量:2
10
作者 ZHANG Peihong,WANG Kan,WAN Huanhuan,MA Zhongjiao(School of Environment Engineering,Shenyang Jianzhu University,Shenyang,China,110168) 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2011年第2期324-330,共7页
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and... The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building. 展开更多
关键词 building facility management evaluation index Fuzzy AHP indoor air quality thermal comfort
在线阅读 下载PDF
Building dynamic thermal simulation of low-order multi-dimensional heat transfer 被引量:1
11
作者 高岩 范蕊 +1 位作者 张群力 J.J.ROUX 《Journal of Central South University》 SCIE EI CAS 2014年第1期293-302,共10页
Multi-dimensional heat transfers modeling is crucial for building simulations of insulated buildings,which are widely used and have multi-dimensional heat transfers characteristics.For this work,state-model-reduction ... Multi-dimensional heat transfers modeling is crucial for building simulations of insulated buildings,which are widely used and have multi-dimensional heat transfers characteristics.For this work,state-model-reduction techniques were used to develop a reduced low-order model of multi-dimensional heat transfers.With hot box experiment of hollow block wall,heat flow relative errors between experiment and low-order model predication were less than 8% and the largest errors were less than 3%.Also,frequency responses of five typical walls,each with different thermal masses or insulation modes,the low-order model and the complete model showed that the low-order model results agree very well in the lower excitation frequency band with deviations appearing only at high frequency.Furthermore,low-order model was used on intersection thermal bridge of a floor slab and exterior wall.Results show that errors between the two models are very small.This low-order model could be coupled with most existing simulation software for different thermal mass envelope analyses to make up for differences between the multi-dimensional and one-dimensional models,simultaneously simplifying simulation calculations. 展开更多
关键词 building envelope thermal mass thermal bridge model reduction buildings simulation
在线阅读 下载PDF
Field study of seasonal thermal comfort and adaptive behavior for occupants in residential buildings of Xi’an,China 被引量:3
12
作者 WEI Na ZHENG Wu-xing +3 位作者 ZHANG Nan ZHAO Sheng-kai ZHAI Yong-chao YANG Liu 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2403-2414,共12页
The study aims to investigate the thermal comfort requirements in residential buildings and to establish an adaptive thermal comfort model in the cold zone of China.A year-long field study was conducted in residential... The study aims to investigate the thermal comfort requirements in residential buildings and to establish an adaptive thermal comfort model in the cold zone of China.A year-long field study was conducted in residential buildings in Xi’an,China.A total of 2069 valid questionnaires,along with indoor environmental parameters were obtained.The results indicated occupants’thermal comfort requirements varied with seasons.The neutral temperatures were 17.9,26.1(highest),25.2,and 17.4℃(lowest),and preferred temperatures were 23.2,25.6(highest),24.8,and 22.4℃(lowest),respectively for spring,summer,autumn,and winter.The neutral temperature and preferred temperature in autumn are close to the neutral temperature in summer,while the neutral temperature and preferred temperature in spring are close to that in winter.Besides,the 80%and 90%acceptable temperature ranges,adaptive thermal comfort models,and thermal comfort zones for each season were established.Human’s adaptability is related to his/her thermal experience of the current season and the previous season.Therefore,compared with the traditional year-round adaptive thermal comfort model,seasonal models can better reflect seasonal variations of human adaptation.This study provides fundamental knowledge of the thermal comfort demand for people in this region. 展开更多
关键词 thermal comfort seasonal variation adaptive thermal comfort model energy saving residential buildings
在线阅读 下载PDF
Research on the green-roof reconstruction strategy of existing buildings in the Yangtze River basin of China 被引量:1
13
作者 Tiejun Zhou Jianwu Xiong 《西部人居环境学刊》 2015年第A01期104-111,共8页
关键词 the Yangtze River basin Green roof Existing building roof Reconstruction technology
在线阅读 下载PDF
Building a New Socialist Countryside, Improving Commission and Agent System of “Village-level Accounting” 被引量:1
14
作者 SHI Hong 《Journal of Northeast Agricultural University(English Edition)》 CAS 2006年第2期192-196,共5页
Rural finance is an issue concerned with rural people, improving rural financial management is important to close the relations of cadres and masses, maintain rural stability, and promote rural economic development. T... Rural finance is an issue concerned with rural people, improving rural financial management is important to close the relations of cadres and masses, maintain rural stability, and promote rural economic development. This article explained the main problems of village financial, the needs of introducing commission and agent system of "village-level accounting" for building a new socialist countryside, and the measures of improving commission and agent system of "village-level accounting". 展开更多
关键词 building a new socialist countryside rural financial management village-level accounting commission and agent system
在线阅读 下载PDF
Modeling and optimization of a multi-carrier renewable energy system for zero-energy consumption buildings 被引量:8
15
作者 SOULEY AGBODJAN Yawovi LIU Zhi-qiang +2 位作者 WANG Jia-qiang YUE Chang LUO Zheng-yi 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2330-2345,共16页
For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sec... For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sector.A proper sizing method was essential for achieving the desired 100%renewable energy system of resources.This paper presented a bi-objective optimization formulation for sizing the MRES using a constrained genetic algorithm(GA)coupled with the loss of power supply probability(LPSP)method to achieve the minimal cost of the system and the reliability of the system to the load real time requirement.An optimization App has been developed in MATLAB environment to offer a user-friendly interface and output the optimized design parameters when given the load demand.A case study of a swimming pool building was used to demonstrate the process of the proposed design method.Compared to the conventional distributed energy system,the MRES is feasible with a lower annual total cost(ATC).Additionally,the ATC decreases as the power supply reliability of the renewable system decreases.There is a decrease of 24%of the annual total cost when the power supply probability is equal to 8%compared to the baseline case with 0%power supply probability. 展开更多
关键词 multi-carrier renewable energy system constrained genetic algorithm loss of power supply probability(LPSP)method zero-energy consumption building optimal device capacity
在线阅读 下载PDF
Thermal performance analysis of building construction with insulated walls in summer days and nights 被引量:2
16
作者 CHEN Ya-bin PEI Xing-wang HAN Bing-zheng 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3613-3625,共13页
In the present study,the insulation mechanism of building walls during the summer days and nights is investigated with a realistic approach to enhance their performance.A fiber layer,as a porous medium with air gaps,i... In the present study,the insulation mechanism of building walls during the summer days and nights is investigated with a realistic approach to enhance their performance.A fiber layer,as a porous medium with air gaps,is used along the wall layers to decrease the energy loss.Meanwhile,the radiation heat flux variation during five days in a row has been considered for each side of the building,and it is tried to reach the optimum values for geometrical factors and find suitable insulation for each side of the building.A lattice Boltzmann method(LBM) based code is developed to simulate the actual chain of the heat transfer which consists of radiation,conduction,forced and natural convection combination within wall layers including fiber porous insulation.The results indicate that for the current insulation model,the effect of natural convection on the heat transfer is not negligible and the existence of the porous layer has caused a positive impact on the heat loss reduction by decreasing the circulation speed.Also,by using the optimum location and thickness for the insulation layer,it is showed that each side of the building has different rates of energy loss during a day,and for the appropriate insulation,they need to be evaluated separately. 展开更多
关键词 performance enhancement building insulation radiation/convection/conduction combination lattice Boltzmann method(LBM)
在线阅读 下载PDF
Impact of UK Building Regulations on design and thermal performance of dwellings
17
作者 LIM D 姚润明 《Journal of Central South University》 SCIE EI CAS 2009年第S1期127-134,共8页
This paper looks at the progressive impact of UK Building Regulations (Part L) on the energy consumption of dwellings with respect to thermal performance of the building envelope. It provides an overview of building l... This paper looks at the progressive impact of UK Building Regulations (Part L) on the energy consumption of dwellings with respect to thermal performance of the building envelope. It provides an overview of building legislation,highlighting progressive improvement in building elemental U-values and compliance methods. The focus centres on Building Regulations from 1965 to 2006,at a time when energy conservation has become an integral component of building control due to environmental concerns. Simulation software is used to compare energy consumption for 5 typical UK dwelling types through a series of case studies which illustrate the rate of impact over recent years. 展开更多
关键词 building REGULATION ENERGY part L theRMAL U-VALUE
在线阅读 下载PDF
Energy-saving potential analysis for teaching building with intermittent heating system in university of Tianjin
18
作者 何乐 孙贺江 《Journal of Central South University》 SCIE EI CAS 2009年第S1期111-117,共7页
An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps wa... An energy consumption analysis based on the heating characteristic of a building with central heat exchanger in a university of Tianjin was done,and the feasibility of intermittent heating with variable speed pumps was discussed. By comparing various methods of energy consumption analysis,a modified Bin method based on the weather data in Tianjin was adopted. The heat consumption of the buildings under intermittent heating mode was calculated and compared with continuous heating mode,the result shows that intermittent heating can reduce energy consumption for 1 941 759 kW·h,save standard coal for 341 t,and reduce pump power consumption for 72 679 kW·h annually. Intermittent operation by means of varying the pump frequency not only leads to savings in fuel consumption and reduction in pollutant emissions,but also reduces operating costs significantly and it is an ideal energy-saving method. By analyzing the results,the recommendations of heating operation regulation and the transformation of pipe network were proposed separately to different kinds of buildings in colleges,such as laboratory building,teaching building. 展开更多
关键词 BIN method INTERMITTENT HEATING METEOROLOGICAL parameters ENERGY-SAVING of buildings
在线阅读 下载PDF
Thermal performance of integration of solar collectors and building envelopes
19
作者 于国清 龚小辉 曹双华 《Journal of Central South University》 SCIE EI CAS 2009年第S1期255-258,共4页
The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studie... The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studied in winter and summer,and compared to envelopes without solar collectors. The results show that the solar collection efficiency is raised in the integration of building envelopes and solar collectors with the air layer doors closed. This is true whether in winter or summer. The increment is higher as the inlet water temperature increases or the ambient temperature is low. In winter,the heat loss is significantly reduced through integration of the building envelopes and solar collectors with the closed air layer doors. The integration with the open air layer door is worse than that without collectors. In summer,the heat gains of the integration of envelopes and solar collectors are more obviously reduced than envelopes without collectors,the integration with the open air layer door is a little better than the closed one,but the difference is very small. 展开更多
关键词 SOLAR COLLECTOR building ENVELOPES SOLAR COLLECTION efficiency heat TRANSFER INTEGRATION
在线阅读 下载PDF
Importance of building maintenance at the time of architectural design of buildings rehabilitated with heritage value
20
作者 Rui Calejo Rodrigues Patrícia Fernandes Rocha 《西安建筑科技大学学报(自然科学版)》 CSCD 北大核心 2011年第6期768-776,共9页
During architectural conception phase,building maintenance problematic is mostly a result of the unintentional use of preconceived architectonical solutions rather than a consequence of a specific influence of mainten... During architectural conception phase,building maintenance problematic is mostly a result of the unintentional use of preconceived architectonical solutions rather than a consequence of a specific influence of maintenance requirements.Hardly the architect in the act of design understands the importance of these solutions in the service life span of a building.Being aware of this,is it possible for the architect to be supplied with a decision support system that allows him to consider the implications of building maintenance since the early design phases? Having awareness of this problem and its consequences in the early design phases a research project was started at the Faculty Engineering of the University of Oporto(FEUP),under which the implications of building maintenance in the act of architectural design is studied.This article presents the methodology developed to identify the needs of maintenance of buildings based on a DSS-decision support system that provides simple tools the architect can use in design phase.This methodology is based on decomposition of building parts-Elements Source of Maintenance ESM-,and subsequently,a set of functional requirements that determine the performance regarding building maintenance on account of architectural decisions.Relevant maintenance actions are defined: Inspection,Pro-action,Cleaning,Correction,Replacement,Legal enforcement,Limits of use.One can thus set up a relationship between the act of design and its performance framework based on behavior,intervention and the ownership of the work of architecture.Using a Multicriteria Analysis(MCA) a qualitative evaluation of different options based on maintenance requirements accomplishment.Conclusions on the importance of architectural conception concerning the building maintenance were clearly arrived at and the utility of the developed decision support tool was also highlighted. 展开更多
关键词 architectural design building maintenance decision supporting system
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部