Active vibration control is an effective way of increasing robustness of the design to meet the stringent accuracy requirements for space structures. This paper presents the results of active damping realized by a pie...Active vibration control is an effective way of increasing robustness of the design to meet the stringent accuracy requirements for space structures. This paper presents the results of active damping realized by a piezoelectric active member to control the vibration of a four-bay four-longern aluminum truss structure with cantilever boundary. The active member, which utilizes a piezoelectric actuating unit and an integrated load cell, is designed for vibration control of the space truss structures. Active damping control is realized using direct velocity feedback around the active member. The placement of the active member as one of the most important factor of affecting the control system performance, is also investigated by modal dissipation energy ratio as indicator. The active damping effectiveness is evaluated by comparing the closed-loop response with the open loop response.展开更多
The dry friction ring-type vibration isolator is considered as an isotropic continuous medium. A method of dry friction hysteresis loop calculation is proposed based on friction force analysis of contact beam. The fri...The dry friction ring-type vibration isolator is considered as an isotropic continuous medium. A method of dry friction hysteresis loop calculation is proposed based on friction force analysis of contact beam. The friction force is modeled as an equivalent distributed moment to use the finite element method (FEM) to calculate the dry friction vibration isolator hysteresis loop, so the damping characteristics can be obtained. A comparison of the hysteresis loop calculation results and the experimental results shows the average relative error is 2.7 %, it proves the calculation method is feasible.展开更多
文摘Active vibration control is an effective way of increasing robustness of the design to meet the stringent accuracy requirements for space structures. This paper presents the results of active damping realized by a piezoelectric active member to control the vibration of a four-bay four-longern aluminum truss structure with cantilever boundary. The active member, which utilizes a piezoelectric actuating unit and an integrated load cell, is designed for vibration control of the space truss structures. Active damping control is realized using direct velocity feedback around the active member. The placement of the active member as one of the most important factor of affecting the control system performance, is also investigated by modal dissipation energy ratio as indicator. The active damping effectiveness is evaluated by comparing the closed-loop response with the open loop response.
基金the National Natural Science Foundation of China(50275030)the"111" Project (B07018)
文摘The dry friction ring-type vibration isolator is considered as an isotropic continuous medium. A method of dry friction hysteresis loop calculation is proposed based on friction force analysis of contact beam. The friction force is modeled as an equivalent distributed moment to use the finite element method (FEM) to calculate the dry friction vibration isolator hysteresis loop, so the damping characteristics can be obtained. A comparison of the hysteresis loop calculation results and the experimental results shows the average relative error is 2.7 %, it proves the calculation method is feasible.