Kunming,a city in southwest China,has a climate that is different from most of the other places in the world because of its unique geographical characteristics.Due to its temperate climate,most of the residential buil...Kunming,a city in southwest China,has a climate that is different from most of the other places in the world because of its unique geographical characteristics.Due to its temperate climate,most of the residential buildings in this region are naturally ventilated.Accordingly,a winter thermal comfort study was conducted in Kunming to reveal the thermal response of residents.Indoor and outdoor environmental parameters were measured,and participants were investigated about their clothing,thermal sensations,thermal preferences,and thermal acceptance using online questionnaires.Data from 162 valid questionnaires were collected in the survey.Although the climate is referred to as“mild”,the survey showed that the indoor temperature during winter was lower than the typical comfort range.Nevertheless,the participants responded that most of them felt neutral and comfortable.The neutral temperature of participants living in Kunming was determined to be 16.96℃.The acceptable thermal sensation vote(TSV)range of the residents is-0.72 to 1.52.The acceptable indoor air temperature range is 15.03℃to 19.55℃,and the optimum indoor air temperature is 17.2℃.According to this study,the existing thermal comfort evaluation models can hardly predict residents’thermal responses in Kunming well.展开更多
High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,tempe...High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,temperature field induced by this kind of transducer in multi-layer media will be simulated through solving Pennes equation with finite difference method,and the influence of initial sound pressure,absorption coefficient,and thickness of different layers of biological tissue as well as thermal conductivity parameter on sound focus and temperature distribution will be analyzed,respectively.The results show that the temperature in focus area increases faster while the initial sound pressure and thermal conductivity increase.The absorption coefficient is smaller,the ultrasound intensity in the focus area is bigger,and the size of the focus area is increasing.When the thicknesses of different layers of tissue change,the focus position changes slightly,but the sound intensity of the focus area will change obviously.The temperature in focus area will rise quickly before reaching a threshold,and then the temperature will keep in the threshold range.展开更多
In this study,the stagnation point transport of second grade fluid with linear stretching under the effects of variable thermal conductivity is considered.Induced magnetic field impact is also incorporated.The nonline...In this study,the stagnation point transport of second grade fluid with linear stretching under the effects of variable thermal conductivity is considered.Induced magnetic field impact is also incorporated.The nonlinear set of particle differential equations is converted into set of ordinary differential equations through appropriate transformation.The resulting equations are then resolved by optimal homotopy analysis method.The effect of pertinent parameters of interest on skin friction coefficient,temperature,induced magnetic field,velocity and local Nusselt number is inspected by generating appropriate plots.For numerical results,the built-in bvp4 c technique in computational software MATLAB is used for the convergence and residual errors of obtained series solution.It is perceived that the induced magnetic field is intensified by increasing β.It can also be observed that skin friction coefficient enhances with increasing value of magnetic parameter depending on the stretching ratio a/c.For the validness of the obtained results,a comparison has been made and an excellent agreement of current study with existing literature is found.展开更多
Energy output and heating effects are essential for vapor-liquid fuel/air cloud detonation in the fuel-air explosive(FAE) applications or explosion accidents. The purpose of this study is to examine the dynamic large-...Energy output and heating effects are essential for vapor-liquid fuel/air cloud detonation in the fuel-air explosive(FAE) applications or explosion accidents. The purpose of this study is to examine the dynamic large-size flame behavior, shock wave propagation law, and instantaneous thermal field generated by unconfined vapor-liquid propylene oxide(PO)/air cloud detonation. Based on computational fluid dynamics(CFD) and combustion theory, a numerical simulation is used to study the detonation process of a PO/air cloud produced by a double-event fuel-air explosive(DEFAE) of 2.16 kg. The large-scale flame behavior is characterized. The flame initially spreads radially and laterally in a wing shape. Subsequently,the developed flame increases with a larger aspect ratio. Moreover, the propagation laws of shock waves at different heights are discussed. The peak pressure of 1.3 m height level with a stepwise decline is obviously different from that of the ground with an amplitude of reversed ’N’ shape. In the vast majority of the first 6.9 m, the destructive effect of the shock wave near the ground is greater than that of the shock wave at 1.3 m height. Furthermore, the dynamic instantaneous isothermal field is demonstrated.The scaling relationship of various isotherms in the instantaneous thermal field with the flame and initial cloud is summarized. The comprehensive numerical model used in this study can be applied to determine the overpressure and temperature distribution in the entire fuel/air cloud detonation field,providing guidance for assessing the extent of damage caused by DEFAE detonation.展开更多
In order to get thermal stress field of the hot section with thermal barrier coating (TBCs), the thermal conductivity and elastic modulus of top-coat are the physical key properties. The porosity of top-coat was teste...In order to get thermal stress field of the hot section with thermal barrier coating (TBCs), the thermal conductivity and elastic modulus of top-coat are the physical key properties. The porosity of top-coat was tested and evaluated under different high temperatures. The relationship between the microstructure (porosity of top-coat) and properties of TBCs were analyzed to predict the thermal properties of ceramic top-coat, such as thermal conductivity and elastic modulus. The temperature and stress field of the vane with TBCs were simulated using two sets of thermal conductivity data and elastic modulus, which are from literatures and this work, respectively. The results show that the temperature and stress distributions change with thermal conductivity and elastic modulus. The differences of maximum temperatures and stress are 6.5% and 8.0%, respectively.展开更多
The powerful alternate magnetic field treatment is an effective not-heat treatment, which improves the coriaceous performance of the material. In order to reveal the effect rule of the powerful alternate magnetic fiel...The powerful alternate magnetic field treatment is an effective not-heat treatment, which improves the coriaceous performance of the material. In order to reveal the effect rule of the powerful alternate magnetic field on the structure capability after thermal plastic forming, the experimental methods were adopted to compare the microcosmic structure of the LY12 aluminium alloy test pieces before and after the powerful alternate magnetic field treatment. The mechanism of the structure refining was analyzed theoretically. According to the effect rule of the alternate magnetic field on critical grain growth work and the magnetic vibration-constriction mechanism, the structure dynamics factors were analyzed. The results show that, after a certain powerful alternate magnetic field treatment, the mechanical capability of the LY12 aluminium alloy after thermal plastic forming can be reinforced, the structure intertwist deriving from the thermal plastic forming becomes even and the branch crystal is also smashed, consequently refines the structure. The powerful alternate magnetic field treatment can be regarded as an effective method to improve metal structure performance after heat plastic forming.展开更多
The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling syst...The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling system is implemented. The mathematic model is established for thermal current field computation, simulation and analysis in the powertrain cabin. The three-dimensional structure of the powertrain cabin is optimized. The validity of the cooling system design is proved. The foundation for optimizing the whole electric transmission system configuration is laid.展开更多
基金Project(2018YFC0704500)supported by the National Key R&D Program of ChinaProjects(51838007,52130803)supported by the National Natural Science Foundation of China。
文摘Kunming,a city in southwest China,has a climate that is different from most of the other places in the world because of its unique geographical characteristics.Due to its temperate climate,most of the residential buildings in this region are naturally ventilated.Accordingly,a winter thermal comfort study was conducted in Kunming to reveal the thermal response of residents.Indoor and outdoor environmental parameters were measured,and participants were investigated about their clothing,thermal sensations,thermal preferences,and thermal acceptance using online questionnaires.Data from 162 valid questionnaires were collected in the survey.Although the climate is referred to as“mild”,the survey showed that the indoor temperature during winter was lower than the typical comfort range.Nevertheless,the participants responded that most of them felt neutral and comfortable.The neutral temperature of participants living in Kunming was determined to be 16.96℃.The acceptable thermal sensation vote(TSV)range of the residents is-0.72 to 1.52.The acceptable indoor air temperature range is 15.03℃to 19.55℃,and the optimum indoor air temperature is 17.2℃.According to this study,the existing thermal comfort evaluation models can hardly predict residents’thermal responses in Kunming well.
基金Project(11174077)supported by the National Natural Science Foundation of ChinaProject(11JJ3079)supported by the Hunan Provincial Natural Science Foundation of ChinaProjects(12C0237,11C0844)supported by the Science Research Program of Education Department of Hunan Province,China
文摘High intensity focused ultrasound(HIFU)therapy is an effective method in clinical treatment of tumors,in order to explore the bio-heat conduction mechanism of in multi-layer media by concave spherical transducer,temperature field induced by this kind of transducer in multi-layer media will be simulated through solving Pennes equation with finite difference method,and the influence of initial sound pressure,absorption coefficient,and thickness of different layers of biological tissue as well as thermal conductivity parameter on sound focus and temperature distribution will be analyzed,respectively.The results show that the temperature in focus area increases faster while the initial sound pressure and thermal conductivity increase.The absorption coefficient is smaller,the ultrasound intensity in the focus area is bigger,and the size of the focus area is increasing.When the thicknesses of different layers of tissue change,the focus position changes slightly,but the sound intensity of the focus area will change obviously.The temperature in focus area will rise quickly before reaching a threshold,and then the temperature will keep in the threshold range.
文摘In this study,the stagnation point transport of second grade fluid with linear stretching under the effects of variable thermal conductivity is considered.Induced magnetic field impact is also incorporated.The nonlinear set of particle differential equations is converted into set of ordinary differential equations through appropriate transformation.The resulting equations are then resolved by optimal homotopy analysis method.The effect of pertinent parameters of interest on skin friction coefficient,temperature,induced magnetic field,velocity and local Nusselt number is inspected by generating appropriate plots.For numerical results,the built-in bvp4 c technique in computational software MATLAB is used for the convergence and residual errors of obtained series solution.It is perceived that the induced magnetic field is intensified by increasing β.It can also be observed that skin friction coefficient enhances with increasing value of magnetic parameter depending on the stretching ratio a/c.For the validness of the obtained results,a comparison has been made and an excellent agreement of current study with existing literature is found.
基金supported by the National Natural Science Foundation of China ( Grant No. 11972089)。
文摘Energy output and heating effects are essential for vapor-liquid fuel/air cloud detonation in the fuel-air explosive(FAE) applications or explosion accidents. The purpose of this study is to examine the dynamic large-size flame behavior, shock wave propagation law, and instantaneous thermal field generated by unconfined vapor-liquid propylene oxide(PO)/air cloud detonation. Based on computational fluid dynamics(CFD) and combustion theory, a numerical simulation is used to study the detonation process of a PO/air cloud produced by a double-event fuel-air explosive(DEFAE) of 2.16 kg. The large-scale flame behavior is characterized. The flame initially spreads radially and laterally in a wing shape. Subsequently,the developed flame increases with a larger aspect ratio. Moreover, the propagation laws of shock waves at different heights are discussed. The peak pressure of 1.3 m height level with a stepwise decline is obviously different from that of the ground with an amplitude of reversed ’N’ shape. In the vast majority of the first 6.9 m, the destructive effect of the shock wave near the ground is greater than that of the shock wave at 1.3 m height. Furthermore, the dynamic instantaneous isothermal field is demonstrated.The scaling relationship of various isotherms in the instantaneous thermal field with the flame and initial cloud is summarized. The comprehensive numerical model used in this study can be applied to determine the overpressure and temperature distribution in the entire fuel/air cloud detonation field,providing guidance for assessing the extent of damage caused by DEFAE detonation.
文摘In order to get thermal stress field of the hot section with thermal barrier coating (TBCs), the thermal conductivity and elastic modulus of top-coat are the physical key properties. The porosity of top-coat was tested and evaluated under different high temperatures. The relationship between the microstructure (porosity of top-coat) and properties of TBCs were analyzed to predict the thermal properties of ceramic top-coat, such as thermal conductivity and elastic modulus. The temperature and stress field of the vane with TBCs were simulated using two sets of thermal conductivity data and elastic modulus, which are from literatures and this work, respectively. The results show that the temperature and stress distributions change with thermal conductivity and elastic modulus. The differences of maximum temperatures and stress are 6.5% and 8.0%, respectively.
基金Project(50675190) supported by the National Natural Science Foundation of China
文摘The powerful alternate magnetic field treatment is an effective not-heat treatment, which improves the coriaceous performance of the material. In order to reveal the effect rule of the powerful alternate magnetic field on the structure capability after thermal plastic forming, the experimental methods were adopted to compare the microcosmic structure of the LY12 aluminium alloy test pieces before and after the powerful alternate magnetic field treatment. The mechanism of the structure refining was analyzed theoretically. According to the effect rule of the alternate magnetic field on critical grain growth work and the magnetic vibration-constriction mechanism, the structure dynamics factors were analyzed. The results show that, after a certain powerful alternate magnetic field treatment, the mechanical capability of the LY12 aluminium alloy after thermal plastic forming can be reinforced, the structure intertwist deriving from the thermal plastic forming becomes even and the branch crystal is also smashed, consequently refines the structure. The powerful alternate magnetic field treatment can be regarded as an effective method to improve metal structure performance after heat plastic forming.
文摘The electric transmission system congfiguration-2 is one of the main electric drives for tracked vehicles. The geometrical model for the power-train cabin is established and the preliminary design for its cooling system is implemented. The mathematic model is established for thermal current field computation, simulation and analysis in the powertrain cabin. The three-dimensional structure of the powertrain cabin is optimized. The validity of the cooling system design is proved. The foundation for optimizing the whole electric transmission system configuration is laid.