The matters of equipment optimization development are usually discrete,fuzzy and non-quantitative.It is difficult directly to optimize the equipment development with a mathematical model.A set of methods for designing...The matters of equipment optimization development are usually discrete,fuzzy and non-quantitative.It is difficult directly to optimize the equipment development with a mathematical model.A set of methods for designing the equipment optimization development with six dimensions and eight main elements is established based on the theory and method of standardization.The top-tier design space of systematic development of equipment is built up by the relations of basic models,series and model spectrums.The relations of time and space for equipment optimization development are established.The design processes of a six dimension systematic space are expounded.The connotation of each plan in the main system space is analyzed.A design method for an entire equipment is established with standardization theory.The coordinating design methods of equipment technical system and the optimization design methods of equipment integration are discussed.The design methods for universalization and serialization of components and parts are established.The design methods of equipment optimization development highlight the relations of the basic model of platform,the serialization of platform basic models,the modularization of equipment functions,the model spectrum of variant equipment,and the universalization and serialization of components and parts.展开更多
为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶...为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。展开更多
文摘The matters of equipment optimization development are usually discrete,fuzzy and non-quantitative.It is difficult directly to optimize the equipment development with a mathematical model.A set of methods for designing the equipment optimization development with six dimensions and eight main elements is established based on the theory and method of standardization.The top-tier design space of systematic development of equipment is built up by the relations of basic models,series and model spectrums.The relations of time and space for equipment optimization development are established.The design processes of a six dimension systematic space are expounded.The connotation of each plan in the main system space is analyzed.A design method for an entire equipment is established with standardization theory.The coordinating design methods of equipment technical system and the optimization design methods of equipment integration are discussed.The design methods for universalization and serialization of components and parts are established.The design methods of equipment optimization development highlight the relations of the basic model of platform,the serialization of platform basic models,the modularization of equipment functions,the model spectrum of variant equipment,and the universalization and serialization of components and parts.
文摘为简化前处理过程,降低方法的检出限,进行了题示研究。采集鱼塘底泥样品,混匀、缩分、冷冻干燥、除杂、研磨、过筛后混匀,分取5.00 g,加入10.0μg·L^(-1)^(13)C_(6)-氯硝柳胺水合物标准溶液0.2 m L和含2.0%(体积分数)氨水的乙腈溶液20 m L,涡旋1 min,超声10 min,离心8 min。上清液于45℃旋蒸至近干,加入2.00 m L 70%(体积分数)乙腈溶液涡旋溶解残留物,再加入200 mg C18涡旋振荡30 s,离心5 min。收集上清液,过0.22μm有机滤膜,滤液采用高效液相色谱-串联质谱法测定。在色谱分析中,以Waters Atiantis^(TM) d C_(18)色谱柱为固定相,水-乙腈体系为流动相进行梯度洗脱;在质谱分析中,以电喷雾离子源负离子(ESI-)模式电离,选择反应监测(SRM)模式检测,内标法定量。结果显示,氯硝柳胺的质量浓度在0.20~50.00μg·L^(-1)内和其定量离子峰面积与同位素内标定量离子峰面积的比值呈线性关系,检出限(3S/N)为0.2μg·kg^(-1)。按照标准加入法进行回收试验,回收率为92.1%~113%,测定值的相对标准偏差(n=6)为1.6%~5.9%。方法用于实际样品的分析,检出的氯硝柳胺的质量分数为0.580~2.18 mg·kg^(-1)。