期刊文献+
共找到10,379篇文章
< 1 2 250 >
每页显示 20 50 100
基底材料对润滑油中金属元素LIBS检测的影响
1
作者 赵静怡 段皓 +2 位作者 蔡明洋 李倩 李业秋 《沈阳理工大学学报》 CAS 2025年第1期78-84,共7页
润滑油中金属元素的含量和成分的变化能反映发动机的使用状态。通过对比四种基底(Al、Ni、Zn、Cu)增强下润滑油中金属元素BaⅡ455.4 nm的激光诱导击穿光谱(LIBS)特性,对不同基底材料的激发效果进行了评价,并利用多元线性回归模型建立了B... 润滑油中金属元素的含量和成分的变化能反映发动机的使用状态。通过对比四种基底(Al、Ni、Zn、Cu)增强下润滑油中金属元素BaⅡ455.4 nm的激光诱导击穿光谱(LIBS)特性,对不同基底材料的激发效果进行了评价,并利用多元线性回归模型建立了Ba元素激发效果与基底元素物理特性的联系。结果表明:第一电离能、蒸发潜热、热传导率对润滑油中金属元素的激发效果影响较小,且呈正相关;相对原子质量、原子序数、熔化潜热、密度对润滑油中金属元素的激发效果影响较大,且呈负相关。该结果为润滑油金属元素LIBS检测过程中基底材料的选择提供了依据,并为提高金属元素检测准确率和检出限提供了一种可行性方案,对发动机故障检测有重要意义。 展开更多
关键词 激光诱导击穿光谱 润滑油 基底材料 多元线性回归
在线阅读 下载PDF
Performance optimization of ammonium dinitramide-based liquid propellant in pulsed laser ablation micro-propulsion using LIBS
2
作者 Luyun JIANG Yutong CHEN +3 位作者 Chentao MAO Jianhui HAN Anmin CHEN Jifei YE 《Plasma Science and Technology》 2025年第1期103-110,共8页
The efficacy of spacecraft propulsion systems significantly depends on the choice of propellant.This study utilized laser-induced breakdown spectroscopy(LIBS)to investigate the impact of different fuel types,fuel rati... The efficacy of spacecraft propulsion systems significantly depends on the choice of propellant.This study utilized laser-induced breakdown spectroscopy(LIBS)to investigate the impact of different fuel types,fuel ratios,and laser energies on the plasma parameters of ammonium dinitramide(ADN)-based liquid propellants.Our findings suggest that 1-allyl-3-methylimidazolium dicyanamide(AMIMDCA)as a fuel choice led to higher plasma temperatures compared to methanol(CH_3OH)and hydroxyethyl hydrazine nitrate(HEHN)under the same experimental conditions.Optimization of the fuel ratio proved critical,and when the AMIMDCA ratio was 21wt.%the propellants could achieve the best propulsion performance.Increasing the incident laser energy not only enhanced the emission spectral intensity but also elevated the plasma temperature and electron density,thereby improving ablation efficiency.Notably,a combination of 100 mJ laser energy and 21wt.%AMIMDCA fuel produced a strong and stable plasma signal.This study contributes to our knowledge of pulsed laser micro-ablation in ADN-based liquid propellants,providing a useful optical diagnostic approach that can help refine the design and enhance the performance of spacecraft propulsion systems. 展开更多
关键词 libs liquid propellant ADN
在线阅读 下载PDF
激光除漆频率对LIBS准确性影响研究
3
作者 杨文锋 王迪升 +2 位作者 钱自然 李绍龙 郑鑫 《激光与红外》 CAS CSCD 北大核心 2024年第10期1562-1568,共7页
验证激光诱导击穿光谱(Laser-Induced Breakdown Spectroscopy,LIBS)技术在千赫兹级激光条件下检测准确性对LIBS技术应用于大区域、高效率激光除漆过程监测具有重要意义。本文采用高频(kHz级)1064nm红外脉冲光纤激光器清洗飞机蒙皮漆层... 验证激光诱导击穿光谱(Laser-Induced Breakdown Spectroscopy,LIBS)技术在千赫兹级激光条件下检测准确性对LIBS技术应用于大区域、高效率激光除漆过程监测具有重要意义。本文采用高频(kHz级)1064nm红外脉冲光纤激光器清洗飞机蒙皮漆层,结合能谱仪测试结果及原子光谱数据库数据,研究千赫兹激光对LIBS光谱谱峰波长和峰值强度的影响,并验证LIBS技术在千赫兹级激光除漆过程中的准确性。结果表明千赫兹谱峰较赫兹谱峰波长位置向蓝光区域偏移,偏移量不大于0.18nm。380nm~425nm范围内的谱峰完全消失,425nm~550nm范围内的谱峰信噪比下降。能谱仪测试结果与赫兹级LIBS光谱协同验证了千赫兹级激光条件下LIBS技术检测效果的准确性。表明在大区域、高效率飞机蒙皮激光除漆过程中,LIBS技术可用于除漆过程监测。本研究可为千赫兹级激光除漆过程LIBS监测提供参考。 展开更多
关键词 激光清洗 高频激光 libs 谱峰波长 峰值强度
在线阅读 下载PDF
“LIBS关键技术与应用”专辑前言
4
作者 姚顺春 郭连波 +1 位作者 俞进 卢渊 《量子电子学报》 CAS CSCD 北大核心 2024年第3期I0001-I0002,共2页
激光诱导击穿光谱(LIBS)是一种基于原子发射光谱的物质分析技术,具有样品预处理简单、系统简洁、原位在线探测、多元素同步分析等优点。随着激光器、光谱仪、人工智能等相关技术的发展,LIBS被广泛应用于流程工业、地理环境、生物医学、... 激光诱导击穿光谱(LIBS)是一种基于原子发射光谱的物质分析技术,具有样品预处理简单、系统简洁、原位在线探测、多元素同步分析等优点。随着激光器、光谱仪、人工智能等相关技术的发展,LIBS被广泛应用于流程工业、地理环境、生物医学、深空探测等诸多领域,被誉为化学分析技术的“未来巨星”。 展开更多
关键词 原子发射光谱 同步分析 化学分析技术 libs 人工智能 流程工业 生物医学 样品预处理
在线阅读 下载PDF
激光诱导击穿光谱(LIBS)分析虚拟仿真实验 被引量:1
5
作者 张天龙 周嘉俊 +3 位作者 汤宏胜 宁晓辉 李延 李华 《大学化学》 CAS 2024年第6期295-302,共8页
虚拟仿真实验作为大型仪器分析实验教学模式的新兴趋势,有效地将虚拟仿真技术与实物仪器教学相结合,最大限度地提升了学生对于大型仪器分析的综合应用能力。本文以激光诱导击穿光谱(LIBS)虚拟仿真实验系统为例,完整地模拟了LIBS系统的... 虚拟仿真实验作为大型仪器分析实验教学模式的新兴趋势,有效地将虚拟仿真技术与实物仪器教学相结合,最大限度地提升了学生对于大型仪器分析的综合应用能力。本文以激光诱导击穿光谱(LIBS)虚拟仿真实验系统为例,完整地模拟了LIBS系统的样品处理、光谱采集、定性分析和定量分析等实际实验场景,通过虚实结合实验教学模式对实验过程进行实时跟踪与综合考评。该实验有助于提高学生自主探究能力和创新意识,培养具有独立思考与实践能力的拔尖人才。 展开更多
关键词 虚拟仿真实验 激光诱导击穿光谱 仪器分析实验 自主性 创造性
在线阅读 下载PDF
基于LIBS光谱实现燃煤企业碳排放量高精度快速预测
6
作者 王猛 刘树林 +4 位作者 刘晓东 孙浩瀚 张颖 李安 刘瑞斌 《西安科技大学学报》 CAS 北大核心 2024年第3期597-603,共7页
准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精... 准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精准预评估为研究目标,通过自行搭建激光诱导击穿光谱(Laser Induced Breakdown Spectroscopy,LIBS)系统和LIBS光谱统计分析,利用主成分分析-偏最小二乘(PCA-PLS)结合小样本算法对训练集进行回归训练,建立了一种煤炭的碳排放预测模型,并通过在新疆A电厂和山东B电厂中的实际应用,证明了LIBS系统在煤质指标分析中的可靠性。结果表明:所提出的预测方法与传统方法相比绝对误差最大为0.0256 t,表现出较好的碳排放预测能力。所提方法可以用于燃煤企业碳排放量的精准预测,为实现煤炭碳排放和煤质指标的预评估提供了一种较为高效的技术解决路径。 展开更多
关键词 激光诱导击穿光谱技术 碳排放 高精度快速预测
在线阅读 下载PDF
基于彩色相机RGGB通道的LIBS等离子体图像采集与分析
7
作者 燕群 李守杰 +5 位作者 卢渊 田野 翟灿旭 郭金家 叶旺全 郑荣儿 《量子电子学报》 CAS CSCD 北大核心 2024年第3期446-454,共9页
激光诱导击穿光谱(LIBS)是一种基于瞬态等离子体的发射光谱,而实现等离子体成像则对LIBS技术研究至关重要。本工作采用低成本的工业彩色相机实现了LIBS等离子体动态观测,本文以相机RGB通道分离出不同波段下的等离子体成像结果,进而实现... 激光诱导击穿光谱(LIBS)是一种基于瞬态等离子体的发射光谱,而实现等离子体成像则对LIBS技术研究至关重要。本工作采用低成本的工业彩色相机实现了LIBS等离子体动态观测,本文以相机RGB通道分离出不同波段下的等离子体成像结果,进而实现对应波段下元素演化情况的动态观测。以铜锌合金靶材进行了方法验证,结果显示所提出的成像方式能够较好地完成不同元素(Zn、Cu、O)扩张情况的表征,且结合带通滤色片可实现更窄波段下的等离子体成像,证明了彩色相机RGB通道用于等离子体成像分析的可行性,为LIBS基础研究提供了一种实用的技术手段。 展开更多
关键词 光谱学 等离子体成像 RGB通道 时间分辨 激光诱导击穿光谱
在线阅读 下载PDF
基于SPA-SVR模型的LIBS铁精矿矿浆中铁品位的在线测量
8
作者 张奇 张占胜 +3 位作者 陈彤 张鹏 齐立峰 孙兰香 《量子电子学报》 CAS CSCD 北大核心 2024年第3期533-542,共10页
浮选是选矿过程中的重要一步,浮选过程中矿浆品位是选矿工艺需要实时掌握的重要指标。实验室开发了基于激光诱导击穿光谱的在线矿浆成分分析仪SIA-LIBSlurry,可以通过采集光谱数据对浮选过程中矿浆的各元素含量进行实时测量。但铁矿浆... 浮选是选矿过程中的重要一步,浮选过程中矿浆品位是选矿工艺需要实时掌握的重要指标。实验室开发了基于激光诱导击穿光谱的在线矿浆成分分析仪SIA-LIBSlurry,可以通过采集光谱数据对浮选过程中矿浆的各元素含量进行实时测量。但铁矿浆光谱数据维度较高,数据间强烈的多重共线性和非线性问题增加了建模的复杂度。为了解决该问题,本工作比较了两种变量选择算法:竞争性自适应重加权算法(CARS)和连续投影算法(SPA),并结合支持向量机回归(SVR)建立定量分析模型。研究结果表明:全谱6116个变量建立的SVR模型精度较低,预测均方根误差为1.45%;CARS筛选出的231个变量建立的CARS-SVR模型的预测能力有所提高,预测均方根误差为1.09%;SPA筛选出的12个变量建模,SPA-SVR模型取得了最佳预测效果,预测均方根误差降到了0.97%。说明SPA-SVR模型具有较高的预测准确率,有助于提高SIA-LIBSlurry分析仪在线监测的准确性。 展开更多
关键词 光谱学 激光诱导击穿光谱 铁矿浆 特征筛选 支持向量机 铁品位
在线阅读 下载PDF
基于LIBS-GD联用技术定量检测黄河水中Cu元素
9
作者 常佳伟 王亚锐 +4 位作者 马鑫荣 韩伟伟 张国鼎 陆泉芳 孙对兄 《量子电子学报》 CAS CSCD 北大核心 2024年第3期514-521,共8页
针对目前定量检测液体中重金属元素含量方法存在的缺陷,引入了激光诱导击穿光谱-辉光放电联用(LIBS-GD)技术,并用于黄河水中铜(Cu)元素的检测。通过对不同质量浓度Cu标准溶液的测定,采用内标法建立了Cu的标准曲线,并得出Cu的检出限为0.0... 针对目前定量检测液体中重金属元素含量方法存在的缺陷,引入了激光诱导击穿光谱-辉光放电联用(LIBS-GD)技术,并用于黄河水中铜(Cu)元素的检测。通过对不同质量浓度Cu标准溶液的测定,采用内标法建立了Cu的标准曲线,并得出Cu的检出限为0.045 mg/L。实验测量了不同采样点黄河水中Cu的质量浓度,并与火焰原子吸收光谱(AAS)方法进行了对比,结果显示,两种方法的测量结果一致性良好。LIBS-GD联用技术在Cu元素检测方面表现出良好的性能,为水体中重金属元素的检测提供了更简便高效的选择。 展开更多
关键词 光谱学 激光诱导击穿光谱-辉光放电联用技术 内标法 铜元素
在线阅读 下载PDF
基于迁移成分分析的火星LIBS光谱数据定量分析方法
10
作者 吴敏浩 陈靖 +3 位作者 郑子宇 李宣佑 王爽 丁宇 《量子电子学报》 CAS CSCD 北大核心 2024年第3期463-472,共10页
火星土壤中的元素成分及其含量是地质演化历史的重要记录载体,可以反映火星环境、气候等信息,因此对火星土壤进行检测和分析具有重要意义。本研究提出了一种迁移成分分析(TCA)结合随机森林(RF)的LIBS定量分析方法,用于预测火星在轨标样... 火星土壤中的元素成分及其含量是地质演化历史的重要记录载体,可以反映火星环境、气候等信息,因此对火星土壤进行检测和分析具有重要意义。本研究提出了一种迁移成分分析(TCA)结合随机森林(RF)的LIBS定量分析方法,用于预测火星在轨标样的K_(2)O质量分数。选取了383种标样在模拟火星环境下的光谱数据作为训练集,6种在轨标样在真实火星环境下的光谱数据作为测试集。使用训练集建立决策树为250棵的RF模型,其平均绝对误差(E_(MA))、均方根误差(E_(RMS))和平均相对误差(E_(MR))分别为1.117、1.148和10.104,预测性能较差。为了缩短训练集和测试集光谱数据之间的分布距离,建立TCA-RF模型并调整参数。相较于RF模型,TCA-RF模型的E_(MA)、E_(RMS)和E_(MR)分别降低了90.7%、88.1%和94.1%。而与参考模型MOC(一种偏最小二乘法结合独立成分分析的模型)对比,TCA-RF模型在预测测试集中K_(2)O质量分数≥0.15%的样品时,其准确性高于MOC模型。因此TCA-RF模型可以为探测火星土壤元素含量提供新的技术手段。 展开更多
关键词 光谱学 激光诱导击穿光谱 火星探测 迁移成分分析 定量分析
在线阅读 下载PDF
SuperCam-LIBS光谱定量分析火星锰元素
11
作者 苏鸣宇 辛艳青 +1 位作者 刘长卿 凌宗成 《量子电子学报》 CAS CSCD 北大核心 2024年第3期473-484,共12页
毅力号火星车携带的SuperCam载荷可以探测火星表面锰元素等成分信息。本研究依据SuperCam团队发布的地质标样激光诱导击穿光谱(LIBS)数据集,提出了一种基于集成学习的火星锰元素定量方法。本研究首先对LIBS光谱进行光谱降噪、去基线等... 毅力号火星车携带的SuperCam载荷可以探测火星表面锰元素等成分信息。本研究依据SuperCam团队发布的地质标样激光诱导击穿光谱(LIBS)数据集,提出了一种基于集成学习的火星锰元素定量方法。本研究首先对LIBS光谱进行光谱降噪、去基线等预处理,随后进行光谱反卷积和分峰拟合,最终建立锰元素的定量方法,实现了锰元素的含量预测。实验评估了传统多变量定量方法(LASSO、弹性网络)和集成学习方法对锰元素定量精度的差异,发现后者的均方根误差相对于前两种传统方法分别平均下降了49%和30%,定量结果更接近样品真实值,表明基于集成学习的定量方法更适用于火星锰元素的定量反演。 展开更多
关键词 光谱学 光谱定量方法 激光诱导击穿光谱 集成学习 火星 锰元素
在线阅读 下载PDF
卤素离子对NELIBS信号的影响研究
12
作者 孙亚楼 吴柯岩 +2 位作者 李智凡 沈洁 王健 《激光技术》 CAS CSCD 北大核心 2024年第3期411-415,共5页
为了提高激光诱导击穿光谱(LIBS)的检测灵敏度,研究了不同种类、不同浓度的卤素离子对LIBS信号增强程度的影响。根据实验条件和吸收光谱信息筛选合适尺寸的银纳米颗粒,两亲性分子十二烷基硫酸钠(SDS)提供粘性力,硅片作为基底,引入卤素... 为了提高激光诱导击穿光谱(LIBS)的检测灵敏度,研究了不同种类、不同浓度的卤素离子对LIBS信号增强程度的影响。根据实验条件和吸收光谱信息筛选合适尺寸的银纳米颗粒,两亲性分子十二烷基硫酸钠(SDS)提供粘性力,硅片作为基底,引入卤素离子与纳米银溶胶反应诱导纳米颗粒发生聚集。结果表明,卤素阴离子可以有效地诱导纳米银颗粒聚集,且卤素阴离子的加入可以显著增强目标元素MgⅠ382.9 nm,383.2nm和383.8 nm的LIBS信号,Mg的检测限提升到μg/L量级;不同种类卤素离子对纳米颗粒增强LIBS(NELIBS)信号增强的作用,即F->Cl->Br->I-。此结果说明卤素阴离子诱导的纳米颗粒团聚现象可以有效增强LIBS信号强度,能够实现液体中元素Mg的检测分析,满足现代分析技术的新要求。 展开更多
关键词 光谱学 激光诱导击穿光谱 纳米颗粒 卤素阴离子
在线阅读 下载PDF
Detection of Al, Mg, Ca, and Zn in copper slag by LIBS combined with calibration curve and PLSR methods
13
作者 贾军伟 刘志峰 +1 位作者 潘从元 薛骅骎 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期132-138,共7页
The precise measurement of Al, Mg, Ca, and Zn composition in copper slag is crucial for effective process control of copper pyrometallurgy. In this study, a remote laser-induced breakdown spectroscopy(LIBS) system was... The precise measurement of Al, Mg, Ca, and Zn composition in copper slag is crucial for effective process control of copper pyrometallurgy. In this study, a remote laser-induced breakdown spectroscopy(LIBS) system was utilized for the spectral analysis of copper slag samples at a distance of 2.5 m. The composition of copper slag was then analyzed using both the calibration curve(CC) method and the partial least squares regression(PLSR) analysis method based on the characteristic spectral intensity ratio. The performance of the two analysis methods was gauged through the determination coefficient(R^(2)), average relative error(ARE), root mean square error of calibration(RMSEC), and root mean square error of prediction(RMSEP). The results demonstrate that the PLSR method significantly improved both R^(2) for the calibration and test sets while reducing ARE, RMSEC, and RMSEP by 50% compared to the CC method. The results suggest that the combination of LIBS and PLSR is a viable approach for effectively detecting the elemental concentration in copper slag and holds potential for online detection of the elemental composition of high-temperature molten copper slag. 展开更多
关键词 copper slag ELEMENT REMOTE libs PLSR
在线阅读 下载PDF
Enhancing silicon spectral emission in LIBS using Tesla coil discharge
14
作者 Shuang CUI Yang LIU +1 位作者 Anmin CHEN Mingxing JIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期132-139,共8页
Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity ... Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields. 展开更多
关键词 libs Tesla coil spectral enhancement SILICON
在线阅读 下载PDF
LIBS测量飞灰含碳量的研究现状及展望
15
作者 杨先茂 喻子彧 +6 位作者 马维喆 覃淮青 杨淇 李承峻 谭淑雯 冯思捷 姚顺春 《量子电子学报》 CAS CSCD 北大核心 2024年第3期421-436,共16页
飞灰含碳量是评价燃煤锅炉燃烧效率的重要参数之一,实现其在线测量对于提高燃煤机组节能水平与智能化发展具有重要意义。激光诱导击穿光谱(LIBS)作为一种具有竞争力的在线快速测量技术,在飞灰含碳量测量方面的应用已取得了较大进步。本... 飞灰含碳量是评价燃煤锅炉燃烧效率的重要参数之一,实现其在线测量对于提高燃煤机组节能水平与智能化发展具有重要意义。激光诱导击穿光谱(LIBS)作为一种具有竞争力的在线快速测量技术,在飞灰含碳量测量方面的应用已取得了较大进步。本文综述了LIBS测量燃煤飞灰含碳量的基础研究进展,根据测量时飞灰样品形态差异,梳理了LIBS在不同测量模式下的测量参数优化方法;总结了目前LIBS测量飞灰含碳量的光谱数据处理方法和定量分析算法的发展趋势;回顾了在实际工业中LIBS测量飞灰含碳量的应用现状,并对未来研究方向进行了展望。 展开更多
关键词 光谱学 飞灰含碳量测量 激光诱导击穿光谱 能源高效利用 应用开发
在线阅读 下载PDF
Laser-induced plasma formation in water with up to 400 mJ double-pulse LIBS
16
作者 Marion HENKEL Michelle SIEMENS +4 位作者 Ralf METHLING Benjamin EMDE Jörg HERMSDORF Steffen FRANKE Diego GONZALEZ 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期93-100,共8页
Double-pulse LIBS is a promising technique for deep-sea applications.LIBS measurements in shallow water with up to 400 mJ each pulse were done to select laser parameters which promote optimized spectral line emission ... Double-pulse LIBS is a promising technique for deep-sea applications.LIBS measurements in shallow water with up to 400 mJ each pulse were done to select laser parameters which promote optimized spectral line emission from plasma even at elevated pressures,where line broadening until loss of most of the spectral information can occur.Optical emission spectroscopy,using a Czerny-Turner spectrometer,has been applied to investigate the dependence of the emitted radiation on laser parameters and hydrostatic pressure.It has been found,that higher laser pulse energies,especially with short pulse delay as required in high water pressure,can also have an adverse effect on the measured spectrum. 展开更多
关键词 double-pulse libs UNDERWATER plasma formation emission spectrosocpy
在线阅读 下载PDF
基于LIBS技术的渣选尾矿中铜元素的在线检测研究
17
作者 陈昊 许进 +8 位作者 冯玉祥 薛骅骎 马志国 潘从元 郝泽飞 贾军伟 贾振杰 张子明 张兵 《现代矿业》 CAS 2024年第9期203-205,209,共4页
白银有色集团股份有限公司选矿公司为及时获知渣选尾矿中准确的铜元素含量,针对化验室取样分析方法存在取样代表性差、分析时间长等问题,采用基于LIBS技术的在线分析仪对铜尾矿中铜元素含量进行了在线检测应用研究。通过分析20个铜尾矿... 白银有色集团股份有限公司选矿公司为及时获知渣选尾矿中准确的铜元素含量,针对化验室取样分析方法存在取样代表性差、分析时间长等问题,采用基于LIBS技术的在线分析仪对铜尾矿中铜元素含量进行了在线检测应用研究。通过分析20个铜尾矿样品中铜元素含量化验室离线检测值与在线检测值,结果表明,平均绝对偏差为0.014%,平均相对偏差为4.79%,线性相关性R^(2)可达0.959以上,满足铜尾矿铜回收率的判断需要,可为铜熔炼渣浮选加工提供指导。 展开更多
关键词 libs 铜尾矿 铜元素 在线检测
在线阅读 下载PDF
准光学薄态下自吸收校正的铜锌合金CF-LIBS定量分析研究
18
作者 张轩搏 李守杰 +5 位作者 李颖 田野 叶旺全 郭金家 郑荣儿 卢渊 《量子电子学报》 CAS CSCD 北大核心 2024年第3期485-495,共11页
免定标(CF)方法是一种面向激光诱导击穿光谱(LIBS)的定量分析方法,可在无定标曲线的情况下直接完成探测元素的含量计算,但传统CF-LIBS的实际定量结果往往与真实值存在一定差距。为了提高CF-LIBS定量分析结果的精度,本文使用三种不同质... 免定标(CF)方法是一种面向激光诱导击穿光谱(LIBS)的定量分析方法,可在无定标曲线的情况下直接完成探测元素的含量计算,但传统CF-LIBS的实际定量结果往往与真实值存在一定差距。为了提高CF-LIBS定量分析结果的精度,本文使用三种不同质量比的标准铜锌合金靶进行CF-LIBS定量分析计算,通过“准光学薄态逼近”和“谱线自吸收校正”,成功实现了合金靶中Zn/Cu质量比的准确定量。在具体实施过程中,首先通过调节“激光能量”和“探测延时”逼近元素双线比的理论强度值,以此寻获等离子体的“准光学薄”状态。在此基础上,根据元素谱线计算相应的自吸收系数,依据该系数进行LIBS光谱强度的修正,以此完成LIBS谱线的自吸收校正。两部分工作的有效结合,显著提升了CF-LIBS定量的分析精度,结果显示测算的铜锌元素质量比与实际含量非常吻合,三种标准铜锌合金靶的定量误差均小于3.5%,证明了本文所提出方法的有效性和合理性,未来有望在其他领域获得应用验证。 展开更多
关键词 光谱学 定量分析 免定标 自吸收校正 准光学薄态 铜锌合金
在线阅读 下载PDF
基于LIBS迭代的工业燃煤锅炉精细化配煤掺烧优化决策技术
19
作者 陈鹏 《工业加热》 CAS 2024年第6期52-55,共4页
配煤掺烧中涉及的燃料种类和成分较多,工业燃煤锅炉的运行效率、氮氧化物产量等受到影响,故提出基于LIBS迭代的工业燃煤锅炉精细化配煤掺烧优化决策技术。分析与阐明配煤掺烧特性,基于LIBS迭代技术,获取配煤元素LIBS光谱数据,利用S-G滤... 配煤掺烧中涉及的燃料种类和成分较多,工业燃煤锅炉的运行效率、氮氧化物产量等受到影响,故提出基于LIBS迭代的工业燃煤锅炉精细化配煤掺烧优化决策技术。分析与阐明配煤掺烧特性,基于LIBS迭代技术,获取配煤元素LIBS光谱数据,利用S-G滤波器去除LIBS光谱噪声数据,应用随机森林方法提取LIBS光谱数据特征,定量检测配煤元素,以氮氧化物产量最小,工业燃煤锅炉效率最大为目标,构造配煤掺烧优化决策函数,制定目标函数求解程序,执行程序即可获得工业燃煤锅炉精细化配煤掺烧优化决策方案。实验数据显示:在不同实验组别背景下,应用提出技术获得的氮氧化物总产量最小值为200 mg·m^(3),工业燃煤锅炉效率最大值为96%,充分证实了提出技术应用性能更优质。 展开更多
关键词 精细化 工业燃煤锅炉 优化决策 libs迭代算法 配煤掺烧 煤质元素分析与预测
在线阅读 下载PDF
A research on the effect of plasma spectrum collection device on LIBS spectral intensity
20
作者 林晓梅 董艳杰 +5 位作者 林京君 黄玉涛 杨江飞 岳星宇 张倬嘉 段鑫杨 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期121-128,共8页
Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this stu... Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this study presents a novel method for acquiring plasma spectral information from various spatial directions.A parabolic-shaped plasma spectral collection device(PSCD)is employed to effectively collect more spectral information into the spectrometer,thereby enhancing the overall spectral intensity.The research objects in this study were soil samples containing different concentrations of heavy metals Pb,Cr,and Cd.The results indicate that the PSCD significantly enhances the spectral signal,with an enhancement rate of up to 45%.Moreover,the signal-to-noise ratio also increases by as much as 36%.Simultaneously,when compared to the absence of a device,it is found that there is no significant variation in plasma temperature when the PSCD is utilized.This observation eliminates the impact of the spatial effect caused by the PSCD on the spectral intensity.Consequently,a concentrationspectral intensity relationship curve is established under the PSCD.The results revealed that the linear fitting R^(2)for Pb,Cr,and Cd increased by 0.011,0.001,and 0.054,respectively.Additionally,the limit of detection(LOD)decreased by 0.361 ppm,0.901 ppm,and 0.602 ppm,respectively.These findings indicate that the spectral enhancement rate elevates with the increase in heavy metal concentration.Hence,the PSCD can effectively enhance the spectral intensity and reduce the detection limit of heavy metals in soil. 展开更多
关键词 libs plasma spectrum collection device spectral enhancement plasma temperature limit of detection
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部