The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-l...A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.展开更多
本研究采用固相萃取-超高效液相色谱-串联质谱法(Solid Phase Extraction-Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry,SPE-UHPLC-MS/MS)对猪肉中氯苯胺灵的残留进行检测。通过优化气相色谱-质谱条件,建立...本研究采用固相萃取-超高效液相色谱-串联质谱法(Solid Phase Extraction-Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry,SPE-UHPLC-MS/MS)对猪肉中氯苯胺灵的残留进行检测。通过优化气相色谱-质谱条件,建立了氯苯胺灵的标准曲线,结果表明,氯苯胺灵在0.50~100.00μg·L^(-1)线性关系良好,相关系数为0.9964。平均加标回收率为85.25%~92.75%,相对标准偏差为1.83%~3.07%。该方法回收率好、精密度高,适用于猪肉中氯苯胺灵的快速、准确检测。展开更多
建立了液相色谱-串联质谱(LC-MS/MS)手性拆分和测定水产品中奥沙西泮和替马西泮对映体残留量的分析方法。样品经乙腈提取2次,40℃条件下氮气浓缩至近干,残渣加入2 mL 50%乙腈-水溶液溶解,采用分散固相萃取净化,LC-MS/MS测定。使用Enanti...建立了液相色谱-串联质谱(LC-MS/MS)手性拆分和测定水产品中奥沙西泮和替马西泮对映体残留量的分析方法。样品经乙腈提取2次,40℃条件下氮气浓缩至近干,残渣加入2 mL 50%乙腈-水溶液溶解,采用分散固相萃取净化,LC-MS/MS测定。使用EnantioPAK■Y1-R(5μm,150 mm×4.6 mm)手性色谱柱,乙腈和0.1%甲酸-5 mmol/L乙酸铵溶液作为流动相,采用等度洗脱方式实现奥沙西泮和替马西泮手性对映体的拆分。目标对映体采用电喷雾正离子(ESI^(+))模式电离,多反应监测(MRM)模式下,内标法测定。目标对映体在0.5~50μg/L质量浓度范围内线性关系良好,相关系数(r^(2))均不低于0.9990。水产品中对映体的检出限和定量下限分别为0.2μg/kg和0.5μg/kg。在5种空白基质中添加低、中、高浓度水平的目标对映体,样品平均加标回收率为82.6%~107%,相对标准偏差(RSD,n=6)为1.6%~9.2%。该方法灵敏可靠、适用性强,可用于不同水产品中奥沙西泮和替马西泮对映体的分析。展开更多
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
基金supported by the Shanghai Pharmaceutical Association
文摘A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.
文摘本研究采用固相萃取-超高效液相色谱-串联质谱法(Solid Phase Extraction-Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry,SPE-UHPLC-MS/MS)对猪肉中氯苯胺灵的残留进行检测。通过优化气相色谱-质谱条件,建立了氯苯胺灵的标准曲线,结果表明,氯苯胺灵在0.50~100.00μg·L^(-1)线性关系良好,相关系数为0.9964。平均加标回收率为85.25%~92.75%,相对标准偏差为1.83%~3.07%。该方法回收率好、精密度高,适用于猪肉中氯苯胺灵的快速、准确检测。