期刊文献+
共找到121,252篇文章
< 1 2 250 >
每页显示 20 50 100
Diagnostic value of morphological features of breast lesions on DWI and T2WI assessed using Breast Imaging Reporting and Data System lexicon descriptors
1
作者 ZHANG Liying ZHANG Tongzhen ZHAO Xin 《南方医科大学学报》 北大核心 2025年第9期1809-1817,共9页
Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer... Objective To qualitatively assess the diagnostic performance of dynamic contrast enhancement(DCE),diffusionweighted imaging(DWI),and T2-weighted imaging(T2WI),alone or in combination,in the evaluation of breast cancer.Methods We retrospectively reviewed the records of 394 consecutive patients with pathologically confirmed breast lesions who had undergone 3-T magnetic resonance imaging(MRI).The morphological characteristics of breast lesions were evaluated using DCE,DWI,and T2WI based on BI-RADS lexicon descriptors by trained radiologists.Patients were categorized into mass and non-mass groups based on MRI characteristics of the lesions,and the differences between benign and malignant lesions in each group were compared.Clinical prediction models for breast cancer diagnosis were constructed using logistic regression analysis.Diagnostic efficacies were compared using the area under the receiver operating characteristic curve(AUC)and DeLong test.Results For mass-like lesions,all the morphological parameters significantly differentiated benign and malignant lesions on consensus DCE,DWI,and T2WI(P<0.05).The combined method(DCE+DWI+T2WI)had a higher AUC(0.865)than any of the individual modality(DCE:0.786;DWI:0.793;T2WI:0.809)(P<0.05).For non-mass-like lesions,DWI signal intensity was a significant predictor of malignancy(P=0.036),but the model using DWI alone had a low AUC(0.669).Conclusion Morphological assessment using the combination of DCE,DWI,and T2WI provides better diagnostic value in differentiating benign and malignant breast mass-like lesions than assessment with only one of the modalities. 展开更多
关键词 breast cancer magnetic resonance imaging diffusion-weighted imaging T2-weighted imaging diagnostic accuracy
在线阅读 下载PDF
Research on variable-speed scanning method for airborne area-array whiskbroom imaging system based on vertical flight path correction
2
作者 JIN Jia-Rong HAN Gui-Cheng +2 位作者 ANG Chong-Ru WU Ren-Fei WANG Yue-Ming 《红外与毫米波学报》 北大核心 2025年第4期511-519,共9页
Airborne area-array whisk-broom imaging systems typically adopt constant-speed scanning schemes.For large-inertia scanning systems,constant-speed scanning requires substantial time to complete the reversal motion,redu... Airborne area-array whisk-broom imaging systems typically adopt constant-speed scanning schemes.For large-inertia scanning systems,constant-speed scanning requires substantial time to complete the reversal motion,reducing the system's adaptability to high-speed reversal scanning and decreasing scanning efficiency.This study proposes a novel sinusoidal variable-speed roll scanning strategy,which reduces abrupt changes in speed and acceleration,minimizing time loss during reversals.Based on the forward image motion compensation strategy in the pitch direction,we establish a line-of-sight(LOS)position calculation model with vertical flight path correction(VFPC),ensuring that the central LOS of the scanned image remains stable on the same horizontal line,facilitating accurate image stitching in whisk-broom imaging.Through theoretical analysis and simulation experiments,the proposed method improves the scanning efficiency by approximately 18.6%at a 90o whiskbroom imaging angle under the same speed height ratio conditions.The new VFPC method enables wide-field,high-resolution imaging,achieving single-line LOS horizontal stability with an accuracy of better than O.4 mrad.The research is of great significance to promote the further development of airborne area-array whisk-broom imaging technology toward wider fields of view,higher speed height ratios,and greater scanning efficiency. 展开更多
关键词 airborne remote sensing whisk-broom imaging image motion vertical flight path correction(VFPC) line-of-sight(LOS)stabilization
在线阅读 下载PDF
A dual-emission carbon dots-based ratiometric sensor for detection and cellular imaging of Mn^(2+)ions
3
作者 ZHANG Yuecheng MA Jing +6 位作者 SUN Lingbo CHEN Fei ZHANG Shiyu ZHANG Yuhan LI Miao ZHANG Yarong MA Hongyan 《中山大学学报(自然科学版)(中英文)》 北大核心 2025年第3期60-73,共14页
Manganese(Mn),an essential trace element in the human body,plays critical roles in many biological processes.Recent studies have discovered that Mn^(2+)may promote or directly activate the cGAS-STING pathway,thereby s... Manganese(Mn),an essential trace element in the human body,plays critical roles in many biological processes.Recent studies have discovered that Mn^(2+)may promote or directly activate the cGAS-STING pathway,thereby subsequently initiating the natural immune response and augmenting antitumor therapy.However,the current lack of accurate methods for Mn^(2+)determination in cells significantly limits their mechanism investigation;hence,it is urgent to establish novel tools to detect Mn^(2+)in cells.In this study,the dual-emission carbon dots were initially synthesized via the one-pot hydrothermal method employing L-aspartic acid and p-phenylenediamine as raw materials.In the presence of Mn^(2+),the emission peak centered at 350 nm exhibited significant enhancement,whereas another peak at 610 nm remained stable.Consequently,a ratiometric sensor for Mn^(2+)determination was established using the signal at 350 nm as the responsive signal and the signal at 610 nm as an internal reference.Under the optimal condition,a good linear relationship was achieved between the F350/F610 value and Mn^(2+)concentration ranging from 0.9 to 15μmol/L,with a calculated LOD of 61 nmol/L.Benefiting from the special Mn^(2+)-induced ratiometric approach,this method demonstrates outstanding sensitivity,selectivity,and stability,rendering it applicable for Mn^(2+)determination in complex biological samples,as well as Mn^(2+)imaging in MKN-45 and LO2 cells. 展开更多
关键词 Mn^(2+) carbon dots RATIOMETRIC cell imaging FLUORESCENCE
在线阅读 下载PDF
Ultrafast Self-powered Near-infrared Photodetectors and Imaging Array Based on Tin-lead Mixed Perovskites
4
作者 LIU Jingjing YANG Zhichun +7 位作者 BAO Haotian MENG Xinqin QI Minru YANG Changgang ZHANG Guofeng QIN Chengbing XIAO Liantuan JIA Suotang 《发光学报》 北大核心 2025年第6期1037-1047,共11页
Tin-lead(Sn-Pb)mixed perovskites are extensively investigated in near-infrared(NIR)photodetectors(PDs)owing to their excellent photoelectric performance.However,achieving high-performance Sn-Pb mixed PDs remains chall... Tin-lead(Sn-Pb)mixed perovskites are extensively investigated in near-infrared(NIR)photodetectors(PDs)owing to their excellent photoelectric performance.However,achieving high-performance Sn-Pb mixed PDs remains challenging,primarily because of the rapid crystallization and the susceptibility of Sn^(2+) to oxidation.To ad⁃dress these issues,this study introduces the multifunctional molecules 2,3-difluorobenzenamine(DBM)to modulate the crystallization of Sn-Pb mixed perovskites and retard the oxidation of Sn^(2+),thereby significantly enhancing film quality.Compared with the pristine film,Sn-Pb mixed perovskite films modulated by DBM molecules exhibit a high⁃ly homogeneous morphology,reduced roughness and defect density.The self-powered NIR PDs fabricated with the improved films have a spectral response range from 300 nm to 1100 nm,a peak responsivity of 0.51 A·W^(-1),a spe⁃cific detectivity as high as 2.46×10^(11)Jones within the NIR region(780 nm to 1100 nm),a linear dynamic range ex⁃ceeding 152 dB,and ultrafast rise/fall time of 123/464 ns.Thanks to the outstanding performance of PDs,the fabri⁃cated 5×5 PDs array demonstrates superior imaging ability in the NIR region up to 980 nm.This work advances the development of Sn-Pb mixed perovskites for NIR detection and paves the way for their commercialization. 展开更多
关键词 tin-lead mixed perovskites near-infrared photodetectors imaging array oxidation crystallization modulation
在线阅读 下载PDF
NIR-II quantum dot-labeled exosomes’imaging in treatment of ischemic peripheral nerve injury
5
作者 OGURA Shingo SHAO Ke-Meng +6 位作者 ZHANG Xiao LI Hui-Zhu FENG Si-Jia WANG Yue-Ming CHEN Jun WU De-Hua WO Yan 《红外与毫米波学报》 北大核心 2025年第5期631-640,共10页
Ischemia is a significant factor affecting the repair of peripheral nerve injuries,while exosomes have been shown to promote angiogenesis.To further investigate the detailed processes and efficacy of exosome thera⁃py ... Ischemia is a significant factor affecting the repair of peripheral nerve injuries,while exosomes have been shown to promote angiogenesis.To further investigate the detailed processes and efficacy of exosome thera⁃py for ischemic peripheral nerve injuries,this study utilized glucose-modified near-infrared-II(NIR-II)quantum dots(QDs)to label adipose-derived stem cell exosomes(QDs-ADSC-Exos),enabling long-term in vivo NIR-II imaging of exosome treatment for ischemic peripheral nerve damage.Experimental results confirmed that QDs can be used for non-invasive in vitro labeling of exosomes,with QDs-ADSC-Exos exhibiting strong fluorescence signals in the NIR-II window and demonstrating favorable NIR-II imaging characteristics in vivo.Notably,QDsADSC-Exos showed accumulation at the site of nerve injury in cases of ischemic peripheral nerve damage.Func⁃tional neurological assessments indicated that QDs-ADSC-Exos effectively promoted neural regeneration.This study highlights the potential of exosomes in treating ischemic peripheral nerve injuries and elucidates the spatio⁃temporal characteristics of exosome therapy,providing objective evidence for the further optimization of exosomebased treatment protocols. 展开更多
关键词 NIR-II imaging quantum dots EXOSOMES peripheral nerve injury vascular injury
在线阅读 下载PDF
A 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran-based near-infrared fluorescence probe for the detection of hydrogen sulfide and imaging of living cells
6
作者 ZHANG Linfang YIN Wenzhu YIN Gui 《无机化学学报》 北大核心 2025年第3期540-548,共9页
Using 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran(TCF)as a near-infrared fluorescent chromophore,we designed and synthesized a TCF-based fluorescent probe TCF-NS by introducing 2,4-dinitrophenyl ether ... Using 2-dicyanomethylene-3-cyano-4,5,5-trimethyl-2,5-dihydrofuran(TCF)as a near-infrared fluorescent chromophore,we designed and synthesized a TCF-based fluorescent probe TCF-NS by introducing 2,4-dinitrophenyl ether as the recognized site for H_(2)S.The probe TCF-NS displayed a rapid-response fluorescent against H_(2)S with high sensitivity and selection but had no significant fluorescence response to other biothiols.Furthermore,TCF-NS was applied to sense H_(2)S in living cells successfully with minimized cytotoxicity and a large Stokes shift. 展开更多
关键词 hydrogen sulfide near⁃infrared fluorescence probe cell imaging
在线阅读 下载PDF
Research process on radioactive^(18)F-labelled chemical agents as positron emission tomography imaging probes for tumour detection
7
作者 WU Rui ZHANG Yankun +2 位作者 LU Jiufu ZHANG Pengfei WANG Yang 《无机化学学报》 北大核心 2025年第9期1702-1718,共17页
Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)G... Malignant tumours always threaten human health.For tumour diagnosis,positron emission tomography(PET)is the most sensitive and advanced imaging technique by radiotracers,such as radioactive^(18)F,^(11)C,^(64)Cu,^(68)Ga,and^(89)Zr.Among the radiotracers,the radioactive^(18)F-labelled chemical agent as PET probes plays a predominant role in monitoring,detecting,treating,and predicting tumours due to its perfect half-life.In this paper,the^(18)F-labelled chemical materials as PET probes are systematically summarized.First,we introduce various radionuclides of PET and elaborate on the mechanism of PET imaging.It highlights the^(18)F-labelled chemical agents used as PET probes,including[^(18)F]-2-deoxy-2-[^(18)F]fluoro-D-glucose([^(18)F]-FDG),^(18)F-labelled amino acids,^(18)F-labelled nucleic acids,^(18)F-labelled receptors,^(18)F-labelled reporter genes,and^(18)F-labelled hypoxia agents.In addition,some PET probes with metal as a supplementary element are introduced briefly.Meanwhile,the^(18)F-labelled nanoparticles for the PET probe and the multi-modality imaging probe are summarized in detail.The approach and strategies for the fabrication of^(18)F-labelled PET probes are also described briefly.The future development of the PET probe is also prospected.The development and application of^(18)F-labelled PET probes will expand our knowledge and shed light on the diagnosis and theranostics of tumours. 展开更多
关键词 ^(18)F RADIOACTIVE imaging positron emission tomography LABELLED TUMOUR
在线阅读 下载PDF
Reverse design of solid propellant grain based on deep learning:Imaging internal ballistic data
8
作者 Lin Sun Xiangyu Peng +4 位作者 Yang Liu Shu Long Weihua Hui Ran Wei Futing Bao 《Defence Technology(防务技术)》 2025年第8期374-385,共12页
The reverse design of solid rocket motor(SRM)propellant grain involves determining the grain geometry to closely match a predefined internal ballistic curve.While existing reverse design methods are feasible,they ofte... The reverse design of solid rocket motor(SRM)propellant grain involves determining the grain geometry to closely match a predefined internal ballistic curve.While existing reverse design methods are feasible,they often face challenges such as lengthy computation times and limited accuracy.To achieve rapid and accurate matching between the targeted ballistic curve and complex grain shape,this paper proposes a novel reverse design method for SRM propellant grain based on time-series data imaging and convolutional neural network(CNN).First,a finocyl grain shape-internal ballistic curve dataset is created using parametric modeling techniques to comprehensively cover the design space.Next,the internal ballistic time-series data is encoded into three-channel images,establishing a potential relationship between the ballistic curves and their image representations.A CNN is then constructed and trained using these encoded images.Once trained,the model enables efficient inference of propellant grain dimensions from a target internal ballistic curve.This paper conducts comparative experiments across various neural network models,validating the effectiveness of the feature extraction method that transforms internal ballistic time-series data into images,as well as its generalization capability across different CNN architectures.Ignition tests were performed based on the predicted propellant grain.The results demonstrate that the relative error between the experimental internal ballistic curves and the target curves is less than 5%,confirming the validity and feasibility of the proposed reverse design methodology. 展开更多
关键词 SRM Propellant grain reverse design Time-series data imaging CNN
在线阅读 下载PDF
A sparse moving array imaging approach for FMCW radar with dualaperture adaptive azimuth ambiguity suppression and adaptive QR decomposition
9
作者 Yanwen Han Xiaopeng Yan +3 位作者 Jiawei Wang Sheng Zheng Hongrui Yu Jian Dai 《Defence Technology(防务技术)》 2025年第8期254-271,共18页
Range-azimuth imaging of ground targets via frequency-modulated continuous wave(FMCW)radar is crucial for effective target detection.However,when the pitch of the moving array constructed during motion exceeds the phy... Range-azimuth imaging of ground targets via frequency-modulated continuous wave(FMCW)radar is crucial for effective target detection.However,when the pitch of the moving array constructed during motion exceeds the physical array aperture,azimuth ambiguity occurs,making range-azimuth imaging on a moving platform challenging.To address this issue,we theoretically analyze azimuth ambiguity generation in sparse motion arrays and propose a dual-aperture adaptive processing(DAAP)method for suppressing azimuth ambiguity.This method combines spatial multiple-input multiple-output(MIMO)arrays with sparse motion arrays to achieve high-resolution range-azimuth imaging.In addition,an adaptive QR decomposition denoising method for sparse array signals based on iterative low-rank matrix approximation(LRMA)and regularized QR is proposed to preprocess sparse motion array signals.Simulations and experiments show that on a two-transmitter-four-receiver array,the signal-to-noise ratio(SNR)of the sparse motion array signal after noise suppression via adaptive QR decomposition can exceed 0 dB,and the azimuth ambiguity signal ratio(AASR)can be reduced to below-20 dB. 展开更多
关键词 Frequency modulated continuous wave (FMCW) Sparse motion array Range-azimuth imaging Azimuth ambiguity suppression DAAP Adaptive QR decomposition
在线阅读 下载PDF
基于ERDAS IMAGING软件的TM影像几何精校正方法初探——以塔里木河流域为例 被引量:28
10
作者 刘志丽 陈曦 《干旱区地理》 CSCD 北大核心 2001年第4期353-358,共6页
遥感图像的几何精校正一直是人们所关注的问题。本文初步探讨了利用ERDASIMAGING软件对塔里木河流域TM影像进行几何精校正的方法。ERDASIMAGING软件进行几何精校正具有操作简便、实用性强、速度快、几何精度高等特点。
关键词 ERDAS imaging TM影像 塔河流域 几何精校正 遥感影像 地面控制点
在线阅读 下载PDF
一种基于Integral Imaging和多基线立体匹配算法的深度测量方法 被引量:9
11
作者 伍春洪 杨扬 游福成 《电子学报》 EI CAS CSCD 北大核心 2006年第6期1090-1095,共6页
Integral Imaging(II)是一种能够记录和显示全真三维场景的图像技术.该技术采用微透镜阵列记录空间场景,空间任意一点的深度信息只需通过一次成像即可直接获得.本文研究结合多基线立体匹配算法采用II直接获取物体空间信息的方法.其结果... Integral Imaging(II)是一种能够记录和显示全真三维场景的图像技术.该技术采用微透镜阵列记录空间场景,空间任意一点的深度信息只需通过一次成像即可直接获得.本文研究结合多基线立体匹配算法采用II直接获取物体空间信息的方法.其结果既可为下一代基于II的三维电视图像的数据处理提供应用基础,同时也可望应用于开发新型的深度测量工具. 展开更多
关键词 INTEGRAL imaging 深度测量 立体匹配 多基线算法 视差分析
在线阅读 下载PDF
基于ERDAS IMAGING的TM影像中较小水体识别方法 被引量:5
12
作者 李小曼 王刚 《计算机应用与软件》 CSCD 北大核心 2008年第4期215-216,共2页
针对利用Landsat TM遥感影像中水体信息识别的常用方法对细小水体识别的局限性作了深入研究,提出了新的基于ERDAS IMAGING的较小水体识别方法。将TM影像中某3个波段组成的假彩色合成图转换到IHS彩色空间,构建模型进行细小水体的识别。... 针对利用Landsat TM遥感影像中水体信息识别的常用方法对细小水体识别的局限性作了深入研究,提出了新的基于ERDAS IMAGING的较小水体识别方法。将TM影像中某3个波段组成的假彩色合成图转换到IHS彩色空间,构建模型进行细小水体的识别。该方法有效地提高了细小水体识别的精度。 展开更多
关键词 LANDSAT TM ERDAS imaging较小水体IHS彩色空间
在线阅读 下载PDF
Integral Imaging与模拟退火相结合的深度测量方法研究 被引量:1
13
作者 刘献如 蔡自兴 +1 位作者 杨欣荣 伍春洪 《系统仿真学报》 CAS CSCD 北大核心 2009年第8期2303-2307,共5页
该文提出一种Integral Imaging和模拟退火相结合的深度测量方法。针对传统立体视深度测量的复杂性,采用全真三维显示技术Integral Imaging成像技术记录空间三维信息。利用带约束的特征匹配算法并综合多种信息分析Integral imaging视图... 该文提出一种Integral Imaging和模拟退火相结合的深度测量方法。针对传统立体视深度测量的复杂性,采用全真三维显示技术Integral Imaging成像技术记录空间三维信息。利用带约束的特征匹配算法并综合多种信息分析Integral imaging视图对之间的视差。将寻找匹配的问题设计为全局能量函数模型,并用模拟退火算法使该能量函数最小化,从而实现所有视图对中所有特征点的匹配。最后结合Integral Imaging深度估算公式获得空间深度信息。仿真结果表明该方法的有效性。 展开更多
关键词 INTEGRAL imaging 带约束的特征匹配 能量函数 模拟退火
在线阅读 下载PDF
Improvedforward—lookingimagingmethodforairbornearrayFMCWSAR 被引量:6
14
作者 侯海平 曲长文 +1 位作者 杨俭 苏峰 《电波科学学报》 EI CSCD 北大核心 2011年第5期944-950,共7页
机载阵列前视合成孔径雷达(SAR)信号模型中忽略载机速度会影响成像。针对该问题,在调频连续波(FMCW)SAR信号模型中考虑了载机速度,分析了栽机速度的影响和裁机连续运动引入的多普勒频率偏移的特点,结合FrequencyScaling算法,研... 机载阵列前视合成孔径雷达(SAR)信号模型中忽略载机速度会影响成像。针对该问题,在调频连续波(FMCW)SAR信号模型中考虑了载机速度,分析了栽机速度的影响和裁机连续运动引入的多普勒频率偏移的特点,结合FrequencyScaling算法,研究了机载阵列FMCWSAR前视成像。成像仿真和性能参数分析表明:改进方法可精确实现载机运动条件下的FMCWSAR前视成像。 展开更多
关键词 SCALING算法 成像仿真 合成孔径雷达 信号模型 连续运动 调频连续波 频率偏移 性能参数
在线阅读 下载PDF
应用新型调制荧光成像系统(Imaging-PAM)原位评估底泥毒性的方法 被引量:1
15
作者 虞龙 苗秀珍 +4 位作者 于洋 张民 阳振 叶琳琳 孔繁翔 《环境化学》 CAS CSCD 北大核心 2010年第6期1116-1120,共5页
应用新型调制叶绿素荧光成像系统Imaging-PAM,通过最大叶绿素荧光量子产量(Fv/Fm)、实际荧光量子产量(YⅡ)指标的测定原位评估了友谊河底泥对斜生栅藻(Scenedesmus obliqnus)的毒性效应.数据显示,在友谊河底泥悬浮液中,栅藻的Fv/Fm和Y... 应用新型调制叶绿素荧光成像系统Imaging-PAM,通过最大叶绿素荧光量子产量(Fv/Fm)、实际荧光量子产量(YⅡ)指标的测定原位评估了友谊河底泥对斜生栅藻(Scenedesmus obliqnus)的毒性效应.数据显示,在友谊河底泥悬浮液中,栅藻的Fv/Fm和YⅡ值在12h前快速上升,12h后呈现出时间-效应型曲线,72h时Fv/Fm和YⅡ分别下降至对照的44%和35%,Fv/Fm和YⅡ的半抑制时间分别为57h和45h.同时,通过对友谊河底泥样品中重金属含量的检测,计算地积累指数(Igeo),得出友谊河底泥中的Hg、Zn和Cu分别为严重污染,重污染和偏重污染水平,这可能是影响藻类光合作用的主要污染物.本研究为进行底泥毒性评估提供了新的原位分析方法。 展开更多
关键词 斜生栅藻 底泥毒性 叶绿素荧光量子产量 imaging-PAM
在线阅读 下载PDF
Application of Superresolution Techniques to Radar Imaging 被引量:4
16
作者 A. Fanrina, F.Prodi & F. Vinelli(Alenia. Una Azienda Finmeccanica. Radar & C2 DivisionVia Tiburtina km. 12.400. 00131 Roma, Italy) 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1994年第1期1-14,共14页
Modern spectral estimation techniques (superresolution in technical jargon) have been applied to many fields of signal processing since many years[1][2]. Application to radar imaging, mainlyto ISAR (Inverse Synthetic ... Modern spectral estimation techniques (superresolution in technical jargon) have been applied to many fields of signal processing since many years[1][2]. Application to radar imaging, mainlyto ISAR (Inverse Synthetic Aperture Radar) is documented in some recent papers[3] to [6]. Applications have been attempted also to SAR (Synthetic Aperture Radar)[7][8]. In these fields the benefit ofspectral estimation reveals in a resolution beyond the Rayleigh limits set by compressed pulse andsynthetic aperture lengths. Furthermore very low sidelobes of point scatterer response are obtained.In this paper superresolution has been applied both to simulated stepped-frequency ISAR dataand to real ERS-1 SAR data; the achieved results are encouraging and suggest a more extensivepractical application of the technique. The paper is organized in two parts. In the first we have applied the autoregressive (AR) and the minimum variance (MV)-Capon methods to improve therange resolution of simulated ISAR data. In the second part we have conceived an upgraded versionof spectral analysis (SPECAN) processing to obtain a SAR image of better quality. The method hasbeen tested on recorded live data of ERS-1 mission. 展开更多
关键词 Radar imaging SAR ISAR ERS- 1 SUPERRESOLUTION
在线阅读 下载PDF
Near-Infrared Imaging Using a High-Speed Monitoring Near Infrared Hyperspectral Camera(Compovision) 被引量:3
17
作者 Daitaro Ishikawa Asako Motomura +1 位作者 Yoko Igarashi Yukihiro Ozaki 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2015年第4期865-869,共5页
This review paper reports near-infrared(NIR)imaging studies using a newly-developed NIR camera,Compovision.Compovision can measure a significantly wide area of 150mm×250mm at high speed of between 2and 5s.It enab... This review paper reports near-infrared(NIR)imaging studies using a newly-developed NIR camera,Compovision.Compovision can measure a significantly wide area of 150mm×250mm at high speed of between 2and 5s.It enables a wide spectral region measurement in the 1 000~2 350nm range at 6nm intervals.We investigated the potential of Compovision in the applications to industrial problems such as the evaluation of pharmaceutical tablets and polymers.Our studies have demonstrated that NIR imaging based on Compovision can solve several issues such as long acquisition times and relatively low sensitivity of detection.NIR imaging with Compovision is strongly expected to be applied not only to pharmaceutical tablet monitoring and polymer characterization but also to various applications such as those to food products,biomedical substances and organic and inorganic materials. 展开更多
关键词 Near infrared spectroscopy imaging Hyperspectral camera
在线阅读 下载PDF
Novel imaging methods of stepped frequency radar based on compressed sensing 被引量:4
18
作者 Jihong Liu Shaokun Xu Xunzhang Gao Xiang Li 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2012年第1期47-56,共10页
The theory of compressed sensing (CS) provides a new chance to reduce the data acquisition time and improve the data usage factor of the stepped frequency radar system. In light of the sparsity of radar target refle... The theory of compressed sensing (CS) provides a new chance to reduce the data acquisition time and improve the data usage factor of the stepped frequency radar system. In light of the sparsity of radar target reflectivity, two imaging methods based on CS, termed the CS-based 2D joint imaging algorithm and the CS-based 2D decoupled imaging algorithm, are proposed. These methods incorporate the coherent mixing operation into the sparse dictionary, and take random measurements in both range and azimuth directions to get high resolution radar images, thus can remarkably reduce the data rate and simplify the hardware design of the radar system while maintaining imaging quality. Ex- periments from both simulated data and measured data in the anechoic chamber show that the proposed imaging methods can get more focused images than the traditional fast Fourier trans- form method. Wherein the joint algorithm has stronger robustness and can provide clearer inverse synthetic aperture radar images, while the decoupled algorithm is computationally more efficient but has slightly degraded imaging quality, which can be improved by increasing measurements or using a robuster recovery algorithm nevertheless. 展开更多
关键词 radar imaging compressed sensing (CS) stepped frequency random sampling.
在线阅读 下载PDF
A fast decoupled ISAR high-resolution imaging method using structural sparse information under low SNR 被引量:6
19
作者 XIANG Long LI Shaodong +2 位作者 YANG Jun CHEN Wenfeng XIANG Hu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第3期492-503,共12页
Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high comp... Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high computational cost and poor imaging quality under a low signal to noise ratio (SNR) condition. This paper proposes a fast decoupled ISAR imaging method by exploiting the inherent structural sparse information of the targets. Firstly, the ISAR imaging problem is decoupled into two sub-problems. One is range direction imaging and the other is azimuth direction focusing. Secondly, an efficient two-stage SR method is proposed to obtain higher resolution range profiles by using jointly sparse information. Finally, the residual linear Bregman iteration via fast Fourier transforms (RLBI-FFT) is proposed to perform the azimuth focusing on low SNR efficiently. Theoretical analysis and simulation results show that the proposed method has better performence to efficiently implement higher-resolution ISAR imaging under the low SNR condition. 展开更多
关键词 SPARSE recovery inverse synthetic APERTURE radar (ISAR) imaging HIGH-RESOLUTION signal to noise ratio (SNR) STRUCTURAL SPARSE INFORMATION
在线阅读 下载PDF
High-resolution forward-looking imaging algorithm for missile-borne detectors 被引量:2
20
作者 CHENG Cheng GAO Min ZHOU Xiaodong 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第3期456-466,共11页
Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missi... Aiming at a novel missile-borne detector in the optional burst height proximity fuze, a self-adaptive high-resolution forward-looking imaging algorithm (SAHRFL-IA) is presented. The echo data are captured by the missile-borne detector in the target regions;thereby the azimuth angulation accuracy at the same distance dimension is improved dynamically. Thus, azimuth information of the targets in the detection area may be obtained accurately. The proposed imaging algorithm breaks through the conventional misconception of merely using azimuth discrimination curves under ideal conditions during monopulse angulation. The real-time echo data from the target region are used to perform error correction for this discrimination curve, and finally the accuracy of the azimuth angulation may reach the optimum at the same distance dimension. A series of experiments demonstrate the validity, reliability and high performance of the proposed imaging algorithm. Azimuth angulation accuracy may reach ten times that of the detection beam width. Meanwhile, the running time of this algorithm satisfies the requirements of missile-borne platforms. 展开更多
关键词 FORWARD-LOOKING imaging HIGH-RESOLUTION missileborne detector SELF-ADAPTIVE radio PROXIMITY FUZE
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部