In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select...In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.展开更多
单相接地故障的高质量调控是支撑新型配电网安全运行的重要环节,针对有源消弧装置AASD(active-type arc suppression device)功能单一、成本高昂等问题,提出1种基于异构单元的有源消弧装置HU-AASD(AASD based on heterogeneous unit)拓...单相接地故障的高质量调控是支撑新型配电网安全运行的重要环节,针对有源消弧装置AASD(active-type arc suppression device)功能单一、成本高昂等问题,提出1种基于异构单元的有源消弧装置HU-AASD(AASD based on heterogeneous unit)拓扑结构及调控策略。首先,HU-AASD利用第四桥臂为虚拟中性点提供电压支撑,使得三相桥臂的耐压需求被降低至相电压,从而降低了AASD的器件成本与体积;其次,所提方案兼具容性和感性无功补偿能力,且接地故障发生后HU-AASD可不间断地向电网提供无功补偿,从而为配电网提供不间断的电压支撑;最后,仿真及实验结果验证了所提拓扑及调控策略的有效性及可行性。展开更多
文摘In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.
文摘单相接地故障的高质量调控是支撑新型配电网安全运行的重要环节,针对有源消弧装置AASD(active-type arc suppression device)功能单一、成本高昂等问题,提出1种基于异构单元的有源消弧装置HU-AASD(AASD based on heterogeneous unit)拓扑结构及调控策略。首先,HU-AASD利用第四桥臂为虚拟中性点提供电压支撑,使得三相桥臂的耐压需求被降低至相电压,从而降低了AASD的器件成本与体积;其次,所提方案兼具容性和感性无功补偿能力,且接地故障发生后HU-AASD可不间断地向电网提供无功补偿,从而为配电网提供不间断的电压支撑;最后,仿真及实验结果验证了所提拓扑及调控策略的有效性及可行性。