Efficiently performing high-resolution direction of arrival(DOA)estimation under low signal-to-noise ratio(SNR)conditions has always been a challenge task in the literatures.Obvi-ously,in order to address this problem...Efficiently performing high-resolution direction of arrival(DOA)estimation under low signal-to-noise ratio(SNR)conditions has always been a challenge task in the literatures.Obvi-ously,in order to address this problem,the key is how to mine or reveal as much DOA related in-formation as possible from the degraded array outputs.However,it is certain that there is no per-fect solution for low SNR DOA estimation designed in the way of winner-takes-all.Therefore,this paper proposes to explore in depth the complementary DOA related information that exists in spa-tial spectrums acquired by different basic DOA estimators.Specifically,these basic spatial spec-trums are employed as the input of multi-source information fusion model.And the multi-source in-formation fusion model is composed of three heterogeneous meta learning machines,namely neural networks(NN),support vector machine(SVM),and random forests(RF).The final meta-spec-trum can be obtained by performing a final decision-making method.Experimental results illus-trate that the proposed information fusion based DOA estimation method can really make full use of the complementary information in the spatial spectrums obtained by different basic DOA estim-ators.Even under low SNR conditions,promising DOA estimation performance can be achieved.展开更多
Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the trans...Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the transverse length of the object, the position of the object in the imaging system and the transverse size of the light source. Furthermore, the effects of these factors on the SNR are discussed in detail by numerical simulations.展开更多
We report a method of high-sensitively detecting the weak signal in photoassociation (PA) spectra of ultracold NaCs molecules by phase sensitive-demodulated trap-loss spectra of Na atoms from a photomultiplier tube....We report a method of high-sensitively detecting the weak signal in photoassociation (PA) spectra of ultracold NaCs molecules by phase sensitive-demodulated trap-loss spectra of Na atoms from a photomultiplier tube. We find that the signal-to-noise ratio (SNR) of the PA spectra is strongly dependent on the integration time and the sensitivity of the lock-in amplifier, and our results show reasonable agreement with the theoretical analyses of the SNR with the demodulation parameters. Meanwhile, we investigate the effect of the interaction time of the PA laser with the colliding Na-Cs atom pairs on the SNR of the PA spectra. The atom loss rate is dependent on both the PA-induced atom loss and the loading of the MOT. The high-sensitive detection of the excited ultracold NaCs molecules lays a solid foundation for further study of the formation and application of ultracold NaCs molecules.展开更多
Raman spectroscopy has been widely used to characterize the physical properties of two-dimensional materials(2DMs).The signal-to-noise ratio(SNR or S/N ratio)of Raman signal usually serves as an important indicator to...Raman spectroscopy has been widely used to characterize the physical properties of two-dimensional materials(2DMs).The signal-to-noise ratio(SNR or S/N ratio)of Raman signal usually serves as an important indicator to evaluate the instrumental performance rather than Raman intensity itself.Multichannel detectors with outstanding sensitivity,rapid acquisition speed and low noise level have been widely equipped in Raman instruments for the measurement of Raman signal.In this mini-review,we first introduce the recent advances of Raman spectroscopy of 2DMs.Then we take the most commonly used CCD detector and IGA array detector as examples to overview the various noise sources in Raman measurements and analyze their potential influences on SNR of Raman signal in experiments.This overview can contribute to a better understanding on the SNR of Raman signal and the performance of multichannel detector for numerous researchers and instrumental design for industry,as well as offer practical strategies for improving spectral quality in routine measurement.展开更多
Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are imp...Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.展开更多
We have investigated the magnetic transition and magnetocaloric effects of Mn1+xCo1-xGe alloys by tuning the ratio of Mn/Co. With increasing Mn content, a series of first-order magnetostructural transitions from ferr...We have investigated the magnetic transition and magnetocaloric effects of Mn1+xCo1-xGe alloys by tuning the ratio of Mn/Co. With increasing Mn content, a series of first-order magnetostructural transitions from ferromagnetic to paramagnetic states with large changes of magnetization are observed at room temperature. Further increasing the content of Mn (x = 0.11) gives rise to a single second-order magnetic transition. Interestingly, large low-field magnetic entropy changes with almost zero magnetic hysteresis are observed in these alloys. The effects of Mn/Co ratio on magnetic transition and magnetocaloric effects are discussed in this paper.展开更多
Fluorescence loss spectrum for detecting cold Rydberg atoms with high sensitivity has been obtained based on lock-in detection of fluorescence of 6 P3/2 state when cooling lasers of the magneto-optical trap are modula...Fluorescence loss spectrum for detecting cold Rydberg atoms with high sensitivity has been obtained based on lock-in detection of fluorescence of 6 P3/2 state when cooling lasers of the magneto-optical trap are modulated.The experiment results show that the signal to noise ratio has been improved by 32.64 dB when the modulation depth(converted to laser frequency)and frequency are optimized to 4 MHz and 6 kHz,respectively.This technique enables us to perform a highly sensitive non-destructive detection of Rydberg atoms.展开更多
The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical co...The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical considerations pertinent to choosing the right CCD camera and unveiling the principles underlying multifarious parameters. Therefore, this analysis can be a valuable tool in scrutinizing each parameter and clarifying proper usage of a scientific CCD camera.展开更多
基金the National Natural Science Foundation of China(Nos.11774073 and 51279033).
文摘Efficiently performing high-resolution direction of arrival(DOA)estimation under low signal-to-noise ratio(SNR)conditions has always been a challenge task in the literatures.Obvi-ously,in order to address this problem,the key is how to mine or reveal as much DOA related in-formation as possible from the degraded array outputs.However,it is certain that there is no per-fect solution for low SNR DOA estimation designed in the way of winner-takes-all.Therefore,this paper proposes to explore in depth the complementary DOA related information that exists in spa-tial spectrums acquired by different basic DOA estimators.Specifically,these basic spatial spec-trums are employed as the input of multi-source information fusion model.And the multi-source in-formation fusion model is composed of three heterogeneous meta learning machines,namely neural networks(NN),support vector machine(SVM),and random forests(RF).The final meta-spec-trum can be obtained by performing a final decision-making method.Experimental results illus-trate that the proposed information fusion based DOA estimation method can really make full use of the complementary information in the spatial spectrums obtained by different basic DOA estim-ators.Even under low SNR conditions,promising DOA estimation performance can be achieved.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11074307 and 10774192)the Opening Research Foundation of State Key Laboratory of Precision Spectroscopy,ECNU
文摘Factors influencing the signal-to-noise ratio (SNR) of lensless ghost interference with thermal incoherent light are investigated. Our result shows that the SNR of lensless ghost interference is related to the transverse length of the object, the position of the object in the imaging system and the transverse size of the light source. Furthermore, the effects of these factors on the SNR are discussed in detail by numerical simulations.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFA0304203)the Chang Jiang Scholars and Innovative Research Team in the University of the Ministry of Education of China(Grant No.IRT13076)+2 种基金the National Natural Science Foundation of China(Grant Nos.91436108,61378014,61675121,61705123,and 61722507)the Fund for Shanxi“1331 Project”Key Subjects Construction,Chinathe Foundation for Outstanding Young Scholars of Shanxi Province,China(Grant No.201601D021001)
文摘We report a method of high-sensitively detecting the weak signal in photoassociation (PA) spectra of ultracold NaCs molecules by phase sensitive-demodulated trap-loss spectra of Na atoms from a photomultiplier tube. We find that the signal-to-noise ratio (SNR) of the PA spectra is strongly dependent on the integration time and the sensitivity of the lock-in amplifier, and our results show reasonable agreement with the theoretical analyses of the SNR with the demodulation parameters. Meanwhile, we investigate the effect of the interaction time of the PA laser with the colliding Na-Cs atom pairs on the SNR of the PA spectra. The atom loss rate is dependent on both the PA-induced atom loss and the loading of the MOT. The high-sensitive detection of the excited ultracold NaCs molecules lays a solid foundation for further study of the formation and application of ultracold NaCs molecules.
基金Project supported by the National Key Research and Development Program of China(Grant No.2016YFA0301204)the National Natural Science Foundation of China(Grant No.11874350)Key Research Program of the Chinese Academy of Sciences(Grant Nos.XDPB22 and ZDBS-LY-SLH004).
文摘Raman spectroscopy has been widely used to characterize the physical properties of two-dimensional materials(2DMs).The signal-to-noise ratio(SNR or S/N ratio)of Raman signal usually serves as an important indicator to evaluate the instrumental performance rather than Raman intensity itself.Multichannel detectors with outstanding sensitivity,rapid acquisition speed and low noise level have been widely equipped in Raman instruments for the measurement of Raman signal.In this mini-review,we first introduce the recent advances of Raman spectroscopy of 2DMs.Then we take the most commonly used CCD detector and IGA array detector as examples to overview the various noise sources in Raman measurements and analyze their potential influences on SNR of Raman signal in experiments.This overview can contribute to a better understanding on the SNR of Raman signal and the performance of multichannel detector for numerous researchers and instrumental design for industry,as well as offer practical strategies for improving spectral quality in routine measurement.
基金Project supported by the National Research and Development Project for Key Scientific Instruments(Grant No.CZBZDYZ20140002)the National Natural Science Foundation of China(Grant Nos.11535015,11305173,and 11375225)+2 种基金the project supported by Institute of High Energy Physics,Chinese Academy of Sciences(Grant No.Y4545320Y2)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)Wali Faiz,acknowledges and wishes to thank the Chinese Academy of Sciences and The World Academy of Sciences(CAS-TWAS)President’s Fellowship Program for generous financial support
文摘Grating-based x-ray phase contrast imaging has the potential to be applied in future medical applications as it is compatible with both laboratory and synchrotron source. However, information retrieval methods are important because acquisition speed, scanning mode, image quality, and radiation dose depend on them. Phase-stepping (PS) is a widely used method to retrieve information, while angular signal radiography (ASR) is a newly established method. In this manuscript, signal-to-noise ratios (SNRs) of ASR are compared with that of PS. Numerical experiments are performed to validate theoretical results. SNRs comparison shows that for refraction and scattering images ASR has higher SNR than PS method, while for absorption image both methods have same SNR. Therefore, our conclusions would have guideline in future preclinical and clinical applications.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 50701022,51001019,and 50831006)the Program for New Century Excellent Talents of China (Grant No. NCET-08-0278)
文摘We have investigated the magnetic transition and magnetocaloric effects of Mn1+xCo1-xGe alloys by tuning the ratio of Mn/Co. With increasing Mn content, a series of first-order magnetostructural transitions from ferromagnetic to paramagnetic states with large changes of magnetization are observed at room temperature. Further increasing the content of Mn (x = 0.11) gives rise to a single second-order magnetic transition. Interestingly, large low-field magnetic entropy changes with almost zero magnetic hysteresis are observed in these alloys. The effects of Mn/Co ratio on magnetic transition and magnetocaloric effects are discussed in this paper.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2017YFA0304203 and 2016YFF0200104)the National Natural Science Foundation of China(Grant Nos.61505099,61827824,91536110,and 61975104)the Fund for Shanxi ‘1331 Project’ Key Subjects Construction,Bairen Project of Shanxi Province,China
文摘Fluorescence loss spectrum for detecting cold Rydberg atoms with high sensitivity has been obtained based on lock-in detection of fluorescence of 6 P3/2 state when cooling lasers of the magneto-optical trap are modulated.The experiment results show that the signal to noise ratio has been improved by 32.64 dB when the modulation depth(converted to laser frequency)and frequency are optimized to 4 MHz and 6 kHz,respectively.This technique enables us to perform a highly sensitive non-destructive detection of Rydberg atoms.
基金supported by the the National Major Technologies R&D Programme of China during the 10th Five-Year Plan Period(No.2001BA302B)the National Science Foundation for Distinguished Young Scholars(No.10225526)+1 种基金the Knowledge Innovation Programme of the Chinese Academy of Sciences(No.KSCX2-SW-324)the Foundation for University Key Teacher by the Ministry of Education(No.2005jq1135).
文摘The proposed multi-dimensional quantitative fluorescence microscopy for the CASLIBB single-particle microbeam II endstation is a CCD-based imaging system. We systematically analyse the theoretical and the practical considerations pertinent to choosing the right CCD camera and unveiling the principles underlying multifarious parameters. Therefore, this analysis can be a valuable tool in scrutinizing each parameter and clarifying proper usage of a scientific CCD camera.