Further development of earthquake equipments is closely associated with that of computer technology. Because Embedded PC104 module has the equivalent functions of PC,it has been widely used in recent years,and can pro...Further development of earthquake equipments is closely associated with that of computer technology. Because Embedded PC104 module has the equivalent functions of PC,it has been widely used in recent years,and can provide a new and flexible hardware design environment,but its applications in observation instruments of earth-quake precursor are rare. The present paper introduces in detail the realization of a networked geo-electrical meter by applying the low price,high reliability embedded PC104 industrial computer.展开更多
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous...A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.展开更多
In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect...In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect of electric and magnetic sources on the operation of electrical controllers like PLC instruments, electrical drivers and actuators which are sensitive to presence of electrical and magnetic fields and also the effect of high voltage power lines展开更多
A hardware-in-the-loop (HWIL) simulator for gun servo system is described in this paper, and its load modeling technologies,such as road spectrum model,sea wave model are studied. The simulation results show that the ...A hardware-in-the-loop (HWIL) simulator for gun servo system is described in this paper, and its load modeling technologies,such as road spectrum model,sea wave model are studied. The simulation results show that the models can be used in HWIL and satisfy the requirements of hardware-in-the-loop simulator of gun servo system.展开更多
Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into p...Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.展开更多
A scheme is proposed,of that the axis of directional barrel is simulated by a laser beam and an electro-optical axial angle encoder is using to measure the swaying of rocket launcher or artillery. The measuring princi...A scheme is proposed,of that the axis of directional barrel is simulated by a laser beam and an electro-optical axial angle encoder is using to measure the swaying of rocket launcher or artillery. The measuring principle is stated,and an electro-optical measuring system is designed,including automatic force-applying device,angle-measurement device and photodetecting screen. The measurement accuracy of the system is analyzed. The measuring error of system is less then 17.3″(0.08 mil).展开更多
More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester....More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5展开更多
A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power netwo...A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power networks.A suitable bus was first identified using modal analysis method.The single shunt capacitor,single SVC,and single STATCOM were installed separately on the most critical bus.The effects of the installation of different devices on power loss reduction,voltage profile improvement,and voltage stability margin enhancement were examined and compared for 57-and 118-bus transmission systems.The comparative study results show that SVC,and STATCOM are expensive compared to shunt capacitor,yet the effect of installing STATCOM is better than SVC and the effect of installing SVC is better than that of shunt capacitor in achieving power loss reduction,voltage profile improvement and voltage stability margin enhancement.展开更多
A fundamental premise of an accelerated testing is that the failure mechanism under elevated and normal stress levels should remain the same. Thus, verification of the consistency of failure mechanisms is essential du...A fundamental premise of an accelerated testing is that the failure mechanism under elevated and normal stress levels should remain the same. Thus, verification of the consistency of failure mechanisms is essential during an accelerated testing. A new consistency analysis method based on the gray theory is pro- posed for complex products. First of all, existing consistency ana- lysis methods are reviewed with a focus on the comparison of the differences among them. Then, the proposed consistency ana- lysis method is introduced. Two effective gray prediction models, gray dynamic model and new information and equal dimensional (NIED) model, are adapted in the proposed method. The process to determine the dimension of NIED model is also discussed, and a decision rule is expanded. Based on that, the procedure of ap- plying the new consistent analysis method is developed. Finally, a case study of the consistency analysis of a reliability enhancement testing is conducted to demonstrate and validate the proposed method.展开更多
Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification perce...Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.展开更多
For measuring velocity and impacting position of single fragment of warhead,a non-contact measuring method is proposed,in which a six-light-screen array,a position indicator,a multi-channel chronograph and a computer ...For measuring velocity and impacting position of single fragment of warhead,a non-contact measuring method is proposed,in which a six-light-screen array,a position indicator,a multi-channel chronograph and a computer are used.The principle of measurement is described.The key device of the system is a light screen array sensor which consists of six light screens allocated with certain geometrical parameters.When the fragment flies through the light screen array,the time of passing through each of the screens is recorded by the multi-channel chronograph.According to the time data and the geometrical parameters of the array,the velocity vector and the location of the fragment can be calculated immediately.The presented method can be used to locate the fragment and to measure the real velocity on its flying direction.It can also be used to measure the velocity of a fragment swarm after the system is engineered further.展开更多
In order to solve the problems which are widespread in potato seeding planter, such as lower operating efficiency, unideal performance index, higher replay rate and leakage rate and uneven spacing sowing in seeding op...In order to solve the problems which are widespread in potato seeding planter, such as lower operating efficiency, unideal performance index, higher replay rate and leakage rate and uneven spacing sowing in seeding operating, a trailed potato fertilization seeder was designed. The key components of the special structure had been got through the description of the structure and working principle of the whole machine. A crossing seed-taken technology along with the vibration component was adopted to achieve precision seeding. The results showed in the feld test of the machine: all the performance indexes of the machine met the agronomic requirement of potato planting; the multiple and missing index were low; it completed the ditching, fertilizing, seeding as well as ridging in one planting process; its operation effciency was high and the stability was good. This design of the trailed potato fertilization seeder provided a reference for the development of large traction-type potato seeding machine.展开更多
A new method is introduced to measure the three parameters of shake quantity,multi-barrel parallelism and zero line using the synthesis of laser collimation,CCD graphic recognized technique and hydraulic press techniq...A new method is introduced to measure the three parameters of shake quantity,multi-barrel parallelism and zero line using the synthesis of laser collimation,CCD graphic recognized technique and hydraulic press technique.The paper describes briefly the principle of the equipment and analyzes the uncertainty.The uncertainty is not more than 15″.展开更多
Vibration intensity and non-dimensional amplitude parameters are often used to extract the fault trend of rotary machines. But,they are the parameters related to energy,and can not describe the fault trend because of ...Vibration intensity and non-dimensional amplitude parameters are often used to extract the fault trend of rotary machines. But,they are the parameters related to energy,and can not describe the fault trend because of varying load and conditions or too slight change of vibration signal. For this reason,three non-dimensional parameters are presented,namely waveform repeatability factor,waveform jumping factor and waveform similarity factor,called as waveform factors jointly,which are based on statistics analysis for the waveform and sensitive to the change of signal waveform. When they are used to extract the fault trend of rotary machines as a kind of technology of instrument and meter,they can reflect the fault trend better than the vibration intensity,peak amplitude and margin index.展开更多
基金"The Study of ELF Receiver"from Ministry of Science and Technology (2001BA601B03-01-03).
文摘Further development of earthquake equipments is closely associated with that of computer technology. Because Embedded PC104 module has the equivalent functions of PC,it has been widely used in recent years,and can provide a new and flexible hardware design environment,but its applications in observation instruments of earth-quake precursor are rare. The present paper introduces in detail the realization of a networked geo-electrical meter by applying the low price,high reliability embedded PC104 industrial computer.
基金Project(JC200903180555A) supported by Shenzhen City Science and Technology Plan, China
文摘A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.
文摘In this paper it has been presented the ELF Survey Meter and its application for investigation of presence of electric and magnetic fields strength in uranium conversion facilities,especially to investigate the effect of electric and magnetic sources on the operation of electrical controllers like PLC instruments, electrical drivers and actuators which are sensitive to presence of electrical and magnetic fields and also the effect of high voltage power lines
文摘A hardware-in-the-loop (HWIL) simulator for gun servo system is described in this paper, and its load modeling technologies,such as road spectrum model,sea wave model are studied. The simulation results show that the models can be used in HWIL and satisfy the requirements of hardware-in-the-loop simulator of gun servo system.
文摘Due to development of distribution systems and increase in electricity demand,the use of capacitor banks increases.From the other point of view,nonlinear loads generate and inject considerable harmonic currents into power system.Under this condition if capacitor banks are not properly selected and placed in the power system,they could amplify and propagate these harmonics and deteriorate power quality to unacceptable levels.With attention of disadvantages of passive filters,such as occurring resonance,nowadays the usage of this type of harmonic compensator is restricted.On the other side,one of parallel multi-function compensating devices which are recently used in distribution system to mitigate voltage sag and harmonic distortion,performs power factor correction,and improves the overall power quality as active power conditioner(APC).Therefore,the utilization of APC in harmonic distorted system can affect and change the optimal location and size of shunt capacitor bank under harmonic distortion condition.This paper presents an optimization algorithm for improvement of power quality using simultaneous optimal placement and sizing of APC and shunt capacitor banks in radial distribution networks in the presence of voltage and current harmonics.The algorithm is based on particle swarm optimization(PSO).The objective function includes the cost of power losses,energy losses and those of the capacitor banks and APCs.
文摘A scheme is proposed,of that the axis of directional barrel is simulated by a laser beam and an electro-optical axial angle encoder is using to measure the swaying of rocket launcher or artillery. The measuring principle is stated,and an electro-optical measuring system is designed,including automatic force-applying device,angle-measurement device and photodetecting screen. The measurement accuracy of the system is analyzed. The measuring error of system is less then 17.3″(0.08 mil).
文摘More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5
文摘A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power networks.A suitable bus was first identified using modal analysis method.The single shunt capacitor,single SVC,and single STATCOM were installed separately on the most critical bus.The effects of the installation of different devices on power loss reduction,voltage profile improvement,and voltage stability margin enhancement were examined and compared for 57-and 118-bus transmission systems.The comparative study results show that SVC,and STATCOM are expensive compared to shunt capacitor,yet the effect of installing STATCOM is better than SVC and the effect of installing SVC is better than that of shunt capacitor in achieving power loss reduction,voltage profile improvement and voltage stability margin enhancement.
基金supported by the National Natural Science Foundation of China(61104132)
文摘A fundamental premise of an accelerated testing is that the failure mechanism under elevated and normal stress levels should remain the same. Thus, verification of the consistency of failure mechanisms is essential during an accelerated testing. A new consistency analysis method based on the gray theory is pro- posed for complex products. First of all, existing consistency ana- lysis methods are reviewed with a focus on the comparison of the differences among them. Then, the proposed consistency ana- lysis method is introduced. Two effective gray prediction models, gray dynamic model and new information and equal dimensional (NIED) model, are adapted in the proposed method. The process to determine the dimension of NIED model is also discussed, and a decision rule is expanded. Based on that, the procedure of ap- plying the new consistent analysis method is developed. Finally, a case study of the consistency analysis of a reliability enhancement testing is conducted to demonstrate and validate the proposed method.
基金Supported by the Youth Science Foundation of Heilongjiang(QC2010119,QC2010028)the Science and Technology Innovation Person with Ability Study Special Foundation Project of Harbin(2011RFQXN054)+1 种基金the Graduate Student Innovative Scientific Research Project of Heilongjiang(YJSCX2011-064JHL)Division of Soybean Machinery,CARS(nycytx-004)
文摘Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.
基金Sponsored by Foundation of Department Education of Shaanxi Province of China(03JC31)Key Lab Foundationin Nanjing University of Science and Technology(51453010103SX0201).
文摘For measuring velocity and impacting position of single fragment of warhead,a non-contact measuring method is proposed,in which a six-light-screen array,a position indicator,a multi-channel chronograph and a computer are used.The principle of measurement is described.The key device of the system is a light screen array sensor which consists of six light screens allocated with certain geometrical parameters.When the fragment flies through the light screen array,the time of passing through each of the screens is recorded by the multi-channel chronograph.According to the time data and the geometrical parameters of the array,the velocity vector and the location of the fragment can be calculated immediately.The presented method can be used to locate the fragment and to measure the real velocity on its flying direction.It can also be used to measure the velocity of a fragment swarm after the system is engineered further.
基金Supported by Funding(2016YFD0701600)from Research and Development of Potato Harvesting Technology and EquipmentSpecial Funds for Construction of Modern Agricultural Technology System(CARS-10-P22)Study on Key Technical Equipment for Scale of Potato Planting(GA15B401)
文摘In order to solve the problems which are widespread in potato seeding planter, such as lower operating efficiency, unideal performance index, higher replay rate and leakage rate and uneven spacing sowing in seeding operating, a trailed potato fertilization seeder was designed. The key components of the special structure had been got through the description of the structure and working principle of the whole machine. A crossing seed-taken technology along with the vibration component was adopted to achieve precision seeding. The results showed in the feld test of the machine: all the performance indexes of the machine met the agronomic requirement of potato planting; the multiple and missing index were low; it completed the ditching, fertilizing, seeding as well as ridging in one planting process; its operation effciency was high and the stability was good. This design of the trailed potato fertilization seeder provided a reference for the development of large traction-type potato seeding machine.
文摘A new method is introduced to measure the three parameters of shake quantity,multi-barrel parallelism and zero line using the synthesis of laser collimation,CCD graphic recognized technique and hydraulic press technique.The paper describes briefly the principle of the equipment and analyzes the uncertainty.The uncertainty is not more than 15″.
文摘Vibration intensity and non-dimensional amplitude parameters are often used to extract the fault trend of rotary machines. But,they are the parameters related to energy,and can not describe the fault trend because of varying load and conditions or too slight change of vibration signal. For this reason,three non-dimensional parameters are presented,namely waveform repeatability factor,waveform jumping factor and waveform similarity factor,called as waveform factors jointly,which are based on statistics analysis for the waveform and sensitive to the change of signal waveform. When they are used to extract the fault trend of rotary machines as a kind of technology of instrument and meter,they can reflect the fault trend better than the vibration intensity,peak amplitude and margin index.