Traditional active power sharing in microgrids,achieved by the distributed average consensus,requires each controller to continuously trigger and communicate with each other,which is a wasteful use of the limited comp...Traditional active power sharing in microgrids,achieved by the distributed average consensus,requires each controller to continuously trigger and communicate with each other,which is a wasteful use of the limited computation and communication resources of the secondary controller.To enhance the efficiency of secondary control,we developed a novel distributed self-triggered active power-sharing control strategy by introducing the signum function and a flexible linear clock.Unlike continuous communication–based controllers,the proposed self-triggered distributed controller prompts distributed generators to perform control actions and share information with their neighbors only at specific time instants monitored by the linear clock.Therefore,this approach results in a significant reduction in both the computation and communication requirements.Moreover,this design naturally avoids Zeno behavior.Furthermore,a modified triggering condition was established to achieve further reductions in computation and communication.The simulation results confirmed that the proposed control scheme achieves distributed active power sharing with very few controller triggers,thereby substantially enhancing the efficacy of secondary control in MGs.展开更多
MV pulsed switch plays a key role as the transfer switch in large electromagnetic pulse simulators. To broaden the range of self-triggering time, a novel spark-discharge pre-ionization switch, in which the main gap el...MV pulsed switch plays a key role as the transfer switch in large electromagnetic pulse simulators. To broaden the range of self-triggering time, a novel spark-discharge pre-ionization switch, in which the main gap electric field is superposed at the trigger gap to let the electrons in its spark channel also become initial electrons, is proposed and tested. The design idea is: as electrons in the spark channel of the trigger gap always exist after its breakdown, the injection time of pre-ionization should have a more negligible effect on reducing the switch jitter. The experiment results under pulses with a rise time of ~100 ns support the above assumptions.When the operating voltage is from ~300 to ~800 kV and the self-triggering time is ~45% to~75% of the peak time, the breakdown time delay jitter is less than 2 ns, and the breakdown voltage jitter is smaller than 1.25%. Under specific self-triggering time, the breakdown time delay jitter is less than 1.5 ns, and the breakdown voltage jitter is smaller than 0.8%.展开更多
Given the rapid development of advanced information systems,microgrids(MGs)suffer from more potential attacks that affect their operational performance.Conventional distributed secondary control with a small,fixed sam...Given the rapid development of advanced information systems,microgrids(MGs)suffer from more potential attacks that affect their operational performance.Conventional distributed secondary control with a small,fixed sampling time period inevitably causes the wasteful use of communication resources.This paper proposes a self-triggered secondary control scheme under perturbations from false data injection(FDI)attacks.We designed a linear clock for each DG to trigger its controller at aperiodic and intermittent instants.Sub-sequently,a hash-based defense mechanism(HDM)is designed for detecting and eliminating malicious data infiltrated in the MGs.With the aid of HDM,a self-triggered control scheme achieves the secondary control objectives even in the presence of FDI attacks.Rigorous theoretical analyses and simulation results indicate that the introduced secondary control scheme significantly reduces communication costs and enhances the resilience of MGs under FDI attacks.展开更多
HFRS(HIAF FRagment Separator) will be the radioactive secondary beam separation line on High-Intensity heavy-ion Accelerator Facility(HIAF) in China. Several TPC detectors, with high count rates, are planned for parti...HFRS(HIAF FRagment Separator) will be the radioactive secondary beam separation line on High-Intensity heavy-ion Accelerator Facility(HIAF) in China. Several TPC detectors, with high count rates, are planned for particle identification and beam monitoring at HFRS. This paper presents an event-driven internal memory and synchronous readout(EDIMS)prototype ASIC chip. The aim is to provide HFRS-TPC with high-precision time and charge measurements with high count rates and a large dynamic range. The first prototype EDIMS chip integrated 16 channels and is fabricated using a 0.18-μm CMOS process. Each channel consists of a charge-sensitive amplifier, fast shaper, slow shaper, peak detect-and-hold circuit, discriminator with time-walk compensation, analog memory, and FIFO. The token ring is used for clock-synchronous readout. The chip is taped and tested.展开更多
基金Key Laboratory of Modern Power System Simulation and Control&Renewable Energy Technology(Northeast Electric Power University)Open Fund(MPSS2023⁃01)National Natural Science Foundation of China(No.52477133)+2 种基金Hainan Provincial Natural Science Foundation of China(No.524RC532)Research Startup Funding from Hainan Institute of Zhejiang University(No.0210-6602-A12202)Project of Sanya Yazhou Bay Science and Technology City(No.SKJC-2022-PTDX-009/010/011).
文摘Traditional active power sharing in microgrids,achieved by the distributed average consensus,requires each controller to continuously trigger and communicate with each other,which is a wasteful use of the limited computation and communication resources of the secondary controller.To enhance the efficiency of secondary control,we developed a novel distributed self-triggered active power-sharing control strategy by introducing the signum function and a flexible linear clock.Unlike continuous communication–based controllers,the proposed self-triggered distributed controller prompts distributed generators to perform control actions and share information with their neighbors only at specific time instants monitored by the linear clock.Therefore,this approach results in a significant reduction in both the computation and communication requirements.Moreover,this design naturally avoids Zeno behavior.Furthermore,a modified triggering condition was established to achieve further reductions in computation and communication.The simulation results confirmed that the proposed control scheme achieves distributed active power sharing with very few controller triggers,thereby substantially enhancing the efficacy of secondary control in MGs.
文摘MV pulsed switch plays a key role as the transfer switch in large electromagnetic pulse simulators. To broaden the range of self-triggering time, a novel spark-discharge pre-ionization switch, in which the main gap electric field is superposed at the trigger gap to let the electrons in its spark channel also become initial electrons, is proposed and tested. The design idea is: as electrons in the spark channel of the trigger gap always exist after its breakdown, the injection time of pre-ionization should have a more negligible effect on reducing the switch jitter. The experiment results under pulses with a rise time of ~100 ns support the above assumptions.When the operating voltage is from ~300 to ~800 kV and the self-triggering time is ~45% to~75% of the peak time, the breakdown time delay jitter is less than 2 ns, and the breakdown voltage jitter is smaller than 1.25%. Under specific self-triggering time, the breakdown time delay jitter is less than 1.5 ns, and the breakdown voltage jitter is smaller than 0.8%.
基金supported by Hainan Provincial Natural Science Foundation of China(No.524RC532)Research Startup Funding from Hainan Institute of Zhejiang University(No.0210-6602-A12202)Project of Sanya Yazhou Bay Science and Technology City(No.SKJC-2022-PTDX-009/010/011).
文摘Given the rapid development of advanced information systems,microgrids(MGs)suffer from more potential attacks that affect their operational performance.Conventional distributed secondary control with a small,fixed sampling time period inevitably causes the wasteful use of communication resources.This paper proposes a self-triggered secondary control scheme under perturbations from false data injection(FDI)attacks.We designed a linear clock for each DG to trigger its controller at aperiodic and intermittent instants.Sub-sequently,a hash-based defense mechanism(HDM)is designed for detecting and eliminating malicious data infiltrated in the MGs.With the aid of HDM,a self-triggered control scheme achieves the secondary control objectives even in the presence of FDI attacks.Rigorous theoretical analyses and simulation results indicate that the introduced secondary control scheme significantly reduces communication costs and enhances the resilience of MGs under FDI attacks.
基金supported by the National Natural Science Foundation of China (Nos. 11975293 and 12105338)the Strategic Priority Research Program of Chinese Academy of Science (Nos. XDB 34040200 and XPB 23)the Technology Innovation Project of Instrument and Equipment Function Development of Chinese Academy of Sciences (No. 2023g102)。
文摘HFRS(HIAF FRagment Separator) will be the radioactive secondary beam separation line on High-Intensity heavy-ion Accelerator Facility(HIAF) in China. Several TPC detectors, with high count rates, are planned for particle identification and beam monitoring at HFRS. This paper presents an event-driven internal memory and synchronous readout(EDIMS)prototype ASIC chip. The aim is to provide HFRS-TPC with high-precision time and charge measurements with high count rates and a large dynamic range. The first prototype EDIMS chip integrated 16 channels and is fabricated using a 0.18-μm CMOS process. Each channel consists of a charge-sensitive amplifier, fast shaper, slow shaper, peak detect-and-hold circuit, discriminator with time-walk compensation, analog memory, and FIFO. The token ring is used for clock-synchronous readout. The chip is taped and tested.