In a global positioning system(GPS)passive radar,a high resolution requires a high sampling frequency,which increases the computational load.Balancing the computational load and the range resolution is challenging.Thi...In a global positioning system(GPS)passive radar,a high resolution requires a high sampling frequency,which increases the computational load.Balancing the computational load and the range resolution is challenging.This paper presents a method to trade off the range resolution and the computational load by experimentally determining the optimal sampling frequency through an analysis of multiple sets of GPS satellite data at different sampling frequencies.The test data are used to construct a range resolution-sampling frequency trade-off model using least-squares estimation.The theoretical analysis shows that the experimental data are the best fit using smoothing and nthorder derivative splines.Using field GPS C/A code signal-based GPS radar,the trade-off between the optimal sampling frequency is determined to be in the 20461.25–24553.5 kHz range,which supports a resolution of 43–48 m.Compared with the conventional method,the CPU time is reduced by approximately 50%.展开更多
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul...In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.展开更多
基金supported by the National Natural Science Foundation of China(42001297)the Research Foundation of Education Department of Hunan Province(19B061)the National Natural Science Foundation of Hunan Province(2021JJ40631)。
文摘In a global positioning system(GPS)passive radar,a high resolution requires a high sampling frequency,which increases the computational load.Balancing the computational load and the range resolution is challenging.This paper presents a method to trade off the range resolution and the computational load by experimentally determining the optimal sampling frequency through an analysis of multiple sets of GPS satellite data at different sampling frequencies.The test data are used to construct a range resolution-sampling frequency trade-off model using least-squares estimation.The theoretical analysis shows that the experimental data are the best fit using smoothing and nthorder derivative splines.Using field GPS C/A code signal-based GPS radar,the trade-off between the optimal sampling frequency is determined to be in the 20461.25–24553.5 kHz range,which supports a resolution of 43–48 m.Compared with the conventional method,the CPU time is reduced by approximately 50%.
基金Project supported by the Priority Academic Development Program of Jiangsu Higher Education Institutions, ChinaProject(CXZZ12_0680) supported by Postgraduate Innovation Foundation of Jiangsu Province, ChinaProject(12JDG082) supported by the Advanced Talent Foundation of Jiangsu University, China
文摘In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.