Background and objective Airway stent placement is the effective regimen for central airway obstruction(CAO),while its application scenarios varied.This study aimed to make clinical comparison of airway stent placemen...Background and objective Airway stent placement is the effective regimen for central airway obstruction(CAO),while its application scenarios varied.This study aimed to make clinical comparison of airway stent placement in the intervention room and operating room.Methods Patients underwent airway stent placement between 2014 and 2018 were included in this retrospective case-control study.Clinical performance of airway stent placement in intervention room and operating room were compared.Results 82 patients were included in this study,including 39 in the intervention room and 43 in the operating room.Patients treated in the intervention room had lower Charlson comorbidity index(CCI)(P=0.018)and received less Y-shaped stents(P<0.001).Better clinical response(P=0.026),more stents placed(P<0.001)and longer length of stent(P<0.001)were observed in operating room,while there was no significantly statistical difference of stent-related complications and post-stent survival rate between the two groups.Extracorporeal membrane oxygenation(ECMO)supported airway stent placement procedures were performed in the operating room,which provided definitive safety support for high-risk intervention.Conclusion Patients with CAO could benefit from the operating room scenario,and airway stent placement in the operating room is more suitable for patients with higher CCI scores and receiving more complicated procedures.展开更多
The stability of room mining coal pillars during their secondary mining for recovering coal was analyzed. An analysis was performed for the damage and instability mechanism of coal pillars recovered by the caving mini...The stability of room mining coal pillars during their secondary mining for recovering coal was analyzed. An analysis was performed for the damage and instability mechanism of coal pillars recovered by the caving mining method. During the damage progression of a single room coal pillar, the shape of the stress distribution in the pillar transformed from the initial stable saddle shape to the final arch-shaped distribution of critical instability. By combining the shapes of stress distribution in the coal pillars with the ultimate strength theory, the safe-stress value of coal pillar was obtained as 11.8 MPa. The mechanism of instability of coal pillar groups recovered by the caving mining method was explained by the domino effect. Since the room coal pillars mined and recovered by the traditional caving mining method were significantly influenced by the secondary mining during recovery, the coal pillars would go through a chain-type instability failure. Because of this limitation, the method of solid backfilling was proposed for mining and recovering room coal pillars, thus changing the transfer mechanism of stress caused by the secondary mining(recovery) of coal pillars. The mechanical model of the stope in the case of backfilling and recovering room coal pillars was built. The peak stress values inside coal pillars varied with the variance of backfilling ratio when the working face was advanced by 150 m. Furthermore, when the critical backfilling ratio was 80.6%, the instability failure of coal pillars would not occur during the solid backfill mining process. By taking Bandingliang Coal Mine as an example, the coal pillars' stability of stope under this backfilling ratio was studied, and a project scheme was designed.展开更多
Room and pillar sizes are key factors for safe mining and ore recovery in open-stope mining. To investigate the influence of room and pillar configurations on stope stability in highly fractured and weakened areas, an...Room and pillar sizes are key factors for safe mining and ore recovery in open-stope mining. To investigate the influence of room and pillar configurations on stope stability in highly fractured and weakened areas, an orthogonal design with two factors, three levels and nine runs was proposed, followed by three-dimensional numerical simulation using ANSYS and FLAC3~. Results show that surface settlement after excavation is concentrically ringed, and increases with the decrease of pillar width and distances to stope gobs. In the meantime, the ore-control fault at the ore-rock boundary and the fractured argillaceous dolomite with intercalated slate at the hanging wall deteriorate the roof settlement. Additionally, stope stability is challenged due to pillar rheological yield and stress concentration, and both are induced by redistribution of stress and plastic zones after mining. Following an objective function and a constraint function, room and pillar configuration with widths of 14 m and 16 m, respectively, is presented as the optimization for improving the ore recovery rate while maintaining a safe working environment.展开更多
A field study and analysis about the thermal comfort was carried out in the waiting room at Beijing West Rail Station in Chinese cold region.Passengers' TSV(thermal sense vote)was obtained using statistical method...A field study and analysis about the thermal comfort was carried out in the waiting room at Beijing West Rail Station in Chinese cold region.Passengers' TSV(thermal sense vote)was obtained using statistical method on the basis of more than 1 200 questionnaires.The linear regression between TSV and indoor temperature indicates that thermal neutral temperature is 25.2 ℃.According to the percentage of satisfaction among all passengers under different indoor temperatures,the acceptable temperature range in the waiting room is 24.2~30.2℃.It is also found that passengers' temporary stay should be taken into consideration for the thermal comfort analysis.Passengers' TSV is not a constant value after they enter the waiting room.In fact,ΔTSV increases as passengers are waiting for the train,and the growing rate is dependent on indoor-outdoor temperature difference.The greater the temperature difference,the faster ΔTSV increases.At last,a linear regression between indoor comfortable temperature and outdoor temperature was generated as the adaptive comfort model.展开更多
More and more attention was paid to phase change energy storage in air conditioning domain and construction energy conservation,and became the focus of the international research. Through the test and analysis of the ...More and more attention was paid to phase change energy storage in air conditioning domain and construction energy conservation,and became the focus of the international research. Through the test and analysis of the parameters of the indoor thermal property in phase change wallboard room and ordinary room,the effects of using phase change wallboards on indoor temperature in summer and air conditioning are obtained. The combination of construct enclosure and phase change materials can stabilize indoor temperature,improve indoor thermal comfort,reduce the frequency of the operation of air conditioning facility,cut the initial investment and operation expense,and meanwhile play an practical role in "the power balancing between the peak period and the valley period" policy. Through the experiment and the test of the effects exerted by phase change wallboard room and ordinary room on the indoor thermal environment,it is obtained that the phase change wallboard can reduce the fluctuation range of indoor temperature and the heat flow from the outside into indoor environment in summer. According to the study,it is found that the effect of cool-storing for 5 h is obvious. Through the analysis of the phase change wallboard without air conditioning in daytime,it is obtained that the frequency of the operation of air conditioning in phase change wallboard room is smaller than that in the ordinary room,which can prolong the lifetime of the facility and reduce operation expense.展开更多
By comparing the thermal performance parameters of an ordinary wall room with a phase change wall (PCW) room,the effect of phase change wallboard on the fluctuation of temperature in air-conditioning room in summer wa...By comparing the thermal performance parameters of an ordinary wall room with a phase change wall (PCW) room,the effect of phase change wallboard on the fluctuation of temperature in air-conditioning room in summer was studied. And PCW room and an ordinary wall room,which are cooled by air-conditioner,were built up. Differential scanning calorimetry (DSC) was used to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested,it is found that the mean temperature of PCW is lower than that of ordinary wall room by 1-2 ℃,and PCW can lower the heat flow by 4.6 W/m2. Combining phase change material to building envelope can lower the indoor temperature,make the room thermal comfortable,and cut down the turn-on-and-off frequency of air-conditioner,the primary investment and operating costs. It alleviates urgent need of the electric power. Building envelope which contains phase change wallboard can improve the indoor thermal environment,and decrease energy consumption in buildings. Phase change wallboard can make impressive effect on energy efficiency of buildings.展开更多
In this paper, the authortries to make a tentative analysis on the short story “The Secret Room” by Alain Robbe Grillet, a French novelist and a contemporary world famous experimentalist of “new novel” form, throu...In this paper, the authortries to make a tentative analysis on the short story “The Secret Room” by Alain Robbe Grillet, a French novelist and a contemporary world famous experimentalist of “new novel” form, through reading in phenomenological approach so as to appreciate his novel style, realize the readers esthetic imagination, meanwhile, to deepen the understanding of the process of phenomenological reading.展开更多
文摘Background and objective Airway stent placement is the effective regimen for central airway obstruction(CAO),while its application scenarios varied.This study aimed to make clinical comparison of airway stent placement in the intervention room and operating room.Methods Patients underwent airway stent placement between 2014 and 2018 were included in this retrospective case-control study.Clinical performance of airway stent placement in intervention room and operating room were compared.Results 82 patients were included in this study,including 39 in the intervention room and 43 in the operating room.Patients treated in the intervention room had lower Charlson comorbidity index(CCI)(P=0.018)and received less Y-shaped stents(P<0.001).Better clinical response(P=0.026),more stents placed(P<0.001)and longer length of stent(P<0.001)were observed in operating room,while there was no significantly statistical difference of stent-related complications and post-stent survival rate between the two groups.Extracorporeal membrane oxygenation(ECMO)supported airway stent placement procedures were performed in the operating room,which provided definitive safety support for high-risk intervention.Conclusion Patients with CAO could benefit from the operating room scenario,and airway stent placement in the operating room is more suitable for patients with higher CCI scores and receiving more complicated procedures.
基金Project(2014ZDPY02)supported by the Fundamental Research Funds for the Central Universities
文摘The stability of room mining coal pillars during their secondary mining for recovering coal was analyzed. An analysis was performed for the damage and instability mechanism of coal pillars recovered by the caving mining method. During the damage progression of a single room coal pillar, the shape of the stress distribution in the pillar transformed from the initial stable saddle shape to the final arch-shaped distribution of critical instability. By combining the shapes of stress distribution in the coal pillars with the ultimate strength theory, the safe-stress value of coal pillar was obtained as 11.8 MPa. The mechanism of instability of coal pillar groups recovered by the caving mining method was explained by the domino effect. Since the room coal pillars mined and recovered by the traditional caving mining method were significantly influenced by the secondary mining during recovery, the coal pillars would go through a chain-type instability failure. Because of this limitation, the method of solid backfilling was proposed for mining and recovering room coal pillars, thus changing the transfer mechanism of stress caused by the secondary mining(recovery) of coal pillars. The mechanical model of the stope in the case of backfilling and recovering room coal pillars was built. The peak stress values inside coal pillars varied with the variance of backfilling ratio when the working face was advanced by 150 m. Furthermore, when the critical backfilling ratio was 80.6%, the instability failure of coal pillars would not occur during the solid backfill mining process. By taking Bandingliang Coal Mine as an example, the coal pillars' stability of stope under this backfilling ratio was studied, and a project scheme was designed.
基金Projects(50934002,51074013,51104100)supported by the National Natural Science Foundation of ChinaProject(IRT0950)supported by the Program for Changjiang Scholars and Innovative Research Team in University of China
文摘Room and pillar sizes are key factors for safe mining and ore recovery in open-stope mining. To investigate the influence of room and pillar configurations on stope stability in highly fractured and weakened areas, an orthogonal design with two factors, three levels and nine runs was proposed, followed by three-dimensional numerical simulation using ANSYS and FLAC3~. Results show that surface settlement after excavation is concentrically ringed, and increases with the decrease of pillar width and distances to stope gobs. In the meantime, the ore-control fault at the ore-rock boundary and the fractured argillaceous dolomite with intercalated slate at the hanging wall deteriorate the roof settlement. Additionally, stope stability is challenged due to pillar rheological yield and stress concentration, and both are induced by redistribution of stress and plastic zones after mining. Following an objective function and a constraint function, room and pillar configuration with widths of 14 m and 16 m, respectively, is presented as the optimization for improving the ore recovery rate while maintaining a safe working environment.
基金Supported by National Natural Science Foundation of China(20676154)
文摘A field study and analysis about the thermal comfort was carried out in the waiting room at Beijing West Rail Station in Chinese cold region.Passengers' TSV(thermal sense vote)was obtained using statistical method on the basis of more than 1 200 questionnaires.The linear regression between TSV and indoor temperature indicates that thermal neutral temperature is 25.2 ℃.According to the percentage of satisfaction among all passengers under different indoor temperatures,the acceptable temperature range in the waiting room is 24.2~30.2℃.It is also found that passengers' temporary stay should be taken into consideration for the thermal comfort analysis.Passengers' TSV is not a constant value after they enter the waiting room.In fact,ΔTSV increases as passengers are waiting for the train,and the growing rate is dependent on indoor-outdoor temperature difference.The greater the temperature difference,the faster ΔTSV increases.At last,a linear regression between indoor comfortable temperature and outdoor temperature was generated as the adaptive comfort model.
基金Project(50878133) supported by the National Natural Science Foundation of ChinaProject(2007R37) supported by the Program Supporting Excellent Talents of Liaoning Province,China+1 种基金Project(2008S193) supported by the Key Laboratory Fund of Education Department of Liaoning Province,ChinaProject(1071211-1-00) supported by the Scientific and Technical Fund Project Subsidy of Shenyang,China
文摘More and more attention was paid to phase change energy storage in air conditioning domain and construction energy conservation,and became the focus of the international research. Through the test and analysis of the parameters of the indoor thermal property in phase change wallboard room and ordinary room,the effects of using phase change wallboards on indoor temperature in summer and air conditioning are obtained. The combination of construct enclosure and phase change materials can stabilize indoor temperature,improve indoor thermal comfort,reduce the frequency of the operation of air conditioning facility,cut the initial investment and operation expense,and meanwhile play an practical role in "the power balancing between the peak period and the valley period" policy. Through the experiment and the test of the effects exerted by phase change wallboard room and ordinary room on the indoor thermal environment,it is obtained that the phase change wallboard can reduce the fluctuation range of indoor temperature and the heat flow from the outside into indoor environment in summer. According to the study,it is found that the effect of cool-storing for 5 h is obvious. Through the analysis of the phase change wallboard without air conditioning in daytime,it is obtained that the frequency of the operation of air conditioning in phase change wallboard room is smaller than that in the ordinary room,which can prolong the lifetime of the facility and reduce operation expense.
基金Project(50878133) supported by the National Natural Science Foundation of ChinaProject(2007R37) supported by the Program of Excellent Talents in Liaoning Province,China+1 种基金Project(2008S193) supported by the Key Laboratory Fund of Education Department in Liaoning Province, ChinaProject(1071211-1-00) supported by the Scientific and Technical Fund of Shenyang,China
文摘By comparing the thermal performance parameters of an ordinary wall room with a phase change wall (PCW) room,the effect of phase change wallboard on the fluctuation of temperature in air-conditioning room in summer was studied. And PCW room and an ordinary wall room,which are cooled by air-conditioner,were built up. Differential scanning calorimetry (DSC) was used to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested,it is found that the mean temperature of PCW is lower than that of ordinary wall room by 1-2 ℃,and PCW can lower the heat flow by 4.6 W/m2. Combining phase change material to building envelope can lower the indoor temperature,make the room thermal comfortable,and cut down the turn-on-and-off frequency of air-conditioner,the primary investment and operating costs. It alleviates urgent need of the electric power. Building envelope which contains phase change wallboard can improve the indoor thermal environment,and decrease energy consumption in buildings. Phase change wallboard can make impressive effect on energy efficiency of buildings.
文摘In this paper, the authortries to make a tentative analysis on the short story “The Secret Room” by Alain Robbe Grillet, a French novelist and a contemporary world famous experimentalist of “new novel” form, through reading in phenomenological approach so as to appreciate his novel style, realize the readers esthetic imagination, meanwhile, to deepen the understanding of the process of phenomenological reading.