To investigate a class of nonlinear network control system, a robust fault diagnosis method is presented based on the robust state observer. To access the objective that the designed robust filter is maximally toleran...To investigate a class of nonlinear network control system, a robust fault diagnosis method is presented based on the robust state observer. To access the objective that the designed robust filter is maximally tolerant to disturbances and sensitive to fault, the robustness and stability properties of the fault diagnosis scheme are established rigorously. Using the residual vector, a fault tolerant controller is established in order to guarantee the stability of the closed-loop system, and the controller law can be obtained by solving a set of linear matrix inequalities. Then, some relevant sufficient conditions for the existence of a solution are given by applying Lyapunov stability theory. Finally, a simulation example is performed to show the effectiveness of the proposed approach.展开更多
Considering packet losses, time-varying delay, and parameter uncertainty in the switched fuzzy system, this paper designs a robust fault detection filter at any switching rate and analyzes the H∞ performance of the s...Considering packet losses, time-varying delay, and parameter uncertainty in the switched fuzzy system, this paper designs a robust fault detection filter at any switching rate and analyzes the H∞ performance of the system. Firstly, the Takagi-Sugeno(T-S) fuzzy model is used to establish a global fuzzy model for the uncertain nonlinear time-delay switched system,and the packet loss process is modeled as a mathematical model satisfying Bernoulli distribution. Secondly, through the average dwell time method and multiple Lyapunov functions, the exponentially stable condition of the nonlinear network switched system is given. Finally, specific parameters of the robust fault detection filter can be obtained by solving linear matrix inequalities(LMIs). The effectiveness of the method is verified by simulation results.展开更多
This paper considers robust fault detection and diagnosis for input uncertain nonlinear systems. It proposes a multi-objective fault detection criterion so that the fault residual is sensitive to the fault but insensi...This paper considers robust fault detection and diagnosis for input uncertain nonlinear systems. It proposes a multi-objective fault detection criterion so that the fault residual is sensitive to the fault but insensitive to the uncertainty as much as possible. Then the paper solves the proposed criterion by maximizing the smallest singular value of the transformation from faults to fault detection residuals while minimizing the largest singular value of the transformation from input uncertainty to the fault detection residuals. This method is applied to an aircraft which has a fault in the left elevator or rudder. The simulation results show the proposed method can detect the control surface failures rapidly and efficiently.展开更多
The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustnes...The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustness performance, and the H- index is used as the sensitivity performance for obtaining the robust fault detection filter. Then a novel multiple Lyapunov-Krasovskii function is proposed for deriving sufficient existence conditions of the robust fault detection filter based on the average dwell time technique. By introducing slack matrix variable, the coupling between the Lyapunov matrix and system matrix is removed, and the conservatism of results is reduced. Based on the robust fault detection filter, residual is generated and evaluated for detecting faults. In addition, the results of this paper are dependent on time delays,and represented in the form of linear matrix inequalities. Finally,the simulation example verifies the effectiveness of the proposed method.展开更多
基金supported by the National Natural Science Foundation of China(90816023).
文摘To investigate a class of nonlinear network control system, a robust fault diagnosis method is presented based on the robust state observer. To access the objective that the designed robust filter is maximally tolerant to disturbances and sensitive to fault, the robustness and stability properties of the fault diagnosis scheme are established rigorously. Using the residual vector, a fault tolerant controller is established in order to guarantee the stability of the closed-loop system, and the controller law can be obtained by solving a set of linear matrix inequalities. Then, some relevant sufficient conditions for the existence of a solution are given by applying Lyapunov stability theory. Finally, a simulation example is performed to show the effectiveness of the proposed approach.
基金supported by the National Natural Science Foundation of China (61471323)。
文摘Considering packet losses, time-varying delay, and parameter uncertainty in the switched fuzzy system, this paper designs a robust fault detection filter at any switching rate and analyzes the H∞ performance of the system. Firstly, the Takagi-Sugeno(T-S) fuzzy model is used to establish a global fuzzy model for the uncertain nonlinear time-delay switched system,and the packet loss process is modeled as a mathematical model satisfying Bernoulli distribution. Secondly, through the average dwell time method and multiple Lyapunov functions, the exponentially stable condition of the nonlinear network switched system is given. Finally, specific parameters of the robust fault detection filter can be obtained by solving linear matrix inequalities(LMIs). The effectiveness of the method is verified by simulation results.
基金supported by the National Natural Science Foundation of China(60328304)the"111"project of Beihang University (B07009)
文摘This paper considers robust fault detection and diagnosis for input uncertain nonlinear systems. It proposes a multi-objective fault detection criterion so that the fault residual is sensitive to the fault but insensitive to the uncertainty as much as possible. Then the paper solves the proposed criterion by maximizing the smallest singular value of the transformation from faults to fault detection residuals while minimizing the largest singular value of the transformation from input uncertainty to the fault detection residuals. This method is applied to an aircraft which has a fault in the left elevator or rudder. The simulation results show the proposed method can detect the control surface failures rapidly and efficiently.
基金supported by the National Natural Science Foundation of China(6127316261403104)
文摘The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustness performance, and the H- index is used as the sensitivity performance for obtaining the robust fault detection filter. Then a novel multiple Lyapunov-Krasovskii function is proposed for deriving sufficient existence conditions of the robust fault detection filter based on the average dwell time technique. By introducing slack matrix variable, the coupling between the Lyapunov matrix and system matrix is removed, and the conservatism of results is reduced. Based on the robust fault detection filter, residual is generated and evaluated for detecting faults. In addition, the results of this paper are dependent on time delays,and represented in the form of linear matrix inequalities. Finally,the simulation example verifies the effectiveness of the proposed method.