This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250...This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups.展开更多
We have measured the cross-section ratios of helium induced by Cq+ and Oq+ (q = 1-4) in an energy range from 20 keV/amu to 500 keV/amu, and obtained the two-dimensional spectra by employing the coincidence method ...We have measured the cross-section ratios of helium induced by Cq+ and Oq+ (q = 1-4) in an energy range from 20 keV/amu to 500 keV/amu, and obtained the two-dimensional spectra by employing the coincidence method combined with the MPA-3 data acquisition system. Hence, we obtain the ratios of total single-ionization cross-sections (SI, SC, SLSI, and DLSI), total double-ionization cross-sections (DI, DC, TI, SLDI, and DLDI) and cross-sections of every process (SI, SC, SLSI, DLSI, DI, DC, TI, SLDI, and DLDI), which induce the single-ionization and double-ionization, to the total cross sections respectively. The competitive relations between the reaction-channels and the experimental data law of each reaction-channel are revealed explicitly, and the qualitative explanations involved in those results are also presented accordingly.展开更多
基金supported by the National Key Scientific Instrument and Equipment Development Projects of China (2014YQ120351)National Natural Science Foundation of China (11704372)Anhui Provincial Natural Science Foundation (1708085QF130)
文摘This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups.
基金Project supported by the National Natural Science Foundation of China(Grant No.10775063)
文摘We have measured the cross-section ratios of helium induced by Cq+ and Oq+ (q = 1-4) in an energy range from 20 keV/amu to 500 keV/amu, and obtained the two-dimensional spectra by employing the coincidence method combined with the MPA-3 data acquisition system. Hence, we obtain the ratios of total single-ionization cross-sections (SI, SC, SLSI, and DLSI), total double-ionization cross-sections (DI, DC, TI, SLDI, and DLDI) and cross-sections of every process (SI, SC, SLSI, DLSI, DI, DC, TI, SLDI, and DLDI), which induce the single-ionization and double-ionization, to the total cross sections respectively. The competitive relations between the reaction-channels and the experimental data law of each reaction-channel are revealed explicitly, and the qualitative explanations involved in those results are also presented accordingly.