Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obt...Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obtained through analyzing the certainty and uncertainty of fuzzy membership functions,which were designed based on well-known Hamming distance.It was applied to the fault detection of primary control surface stuck of uninhabited aerial vehicle(UAV).At post-failure control surface,if the UAV is controllable and trimmable using other control surfaces,the UAV is able to fly or return to the safety region through reconfiguration of flight control system.To detect the fault,similarity measure computations were carried out.This result could be applicable with the real-time parameter estimation method.By monitoring the value of coefficients due to the control surface deviation,it becomes aware that the control surface fault occurs or not.The control surface stuck position and value were separated by comparing the trim value with the reference value.This is the advantage of increasing in reliability without adding sensors or with additional low cost.展开更多
Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and t...Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.展开更多
基金Project(20110018394) supported by Key Research Institute Program through the National Research Foundation (NRF) of Korea
文摘Similarity measure construction has been proposed as fault detection of flight test method in order to obtain the primary control surface stuck and the combination stuck of primary control.Similarity measures were obtained through analyzing the certainty and uncertainty of fuzzy membership functions,which were designed based on well-known Hamming distance.It was applied to the fault detection of primary control surface stuck of uninhabited aerial vehicle(UAV).At post-failure control surface,if the UAV is controllable and trimmable using other control surfaces,the UAV is able to fly or return to the safety region through reconfiguration of flight control system.To detect the fault,similarity measure computations were carried out.This result could be applicable with the real-time parameter estimation method.By monitoring the value of coefficients due to the control surface deviation,it becomes aware that the control surface fault occurs or not.The control surface stuck position and value were separated by comparing the trim value with the reference value.This is the advantage of increasing in reliability without adding sensors or with additional low cost.
基金Project(50838009) supported by the National Science Key Foundation 1 tem
文摘Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.
基金国家自然科学基金项目(51504253)江苏省自然科学基金项目(BK20161185)+1 种基金Project Supported by National Natural Science Foundation of China(51504253)Natural Science Foundation of Jiangsu Province(BK20161185)