In view of the serious reactive power loss in the rural network, improved ant colony optimization algorithm (ACOA) was used to optimize the reactive power compensation for the rural distribution system. In this stud...In view of the serious reactive power loss in the rural network, improved ant colony optimization algorithm (ACOA) was used to optimize the reactive power compensation for the rural distribution system. In this study, the traditional ACOA was improved in two aspects: one was the local search strategy, and the other was pheromone mutation and re-initialization strategies. The reactive power optimization for a county's distribution network showed that the improved ACOA was practicable.展开更多
为研究南方电网500 k V东莞站首个链式35 k V±200 MVA STATCOM在各种主网故障情况下暂态响应的能力和情况,理论计算了500 k V东莞站附近主要枢纽变电站短路故障对其220 k V母线电压的影响;在PSCAD/EMTDC仿真平台上编写了数据处理程...为研究南方电网500 k V东莞站首个链式35 k V±200 MVA STATCOM在各种主网故障情况下暂态响应的能力和情况,理论计算了500 k V东莞站附近主要枢纽变电站短路故障对其220 k V母线电压的影响;在PSCAD/EMTDC仿真平台上编写了数据处理程序,根据STATCOM投运3 a来500 k V东莞站及周边强联系的枢纽变电站发生典型的、严重接地短路或者相间短路故障的运行数据,对STATCOM的响应情况进行深入分析,验证了STATCOM的进入和退出暂态的条件及策略的正确性;计算了STATCOM在系统电压暂降时实际对电网无功支撑量;结果表明STATCOM能在20 ms内正确响应,为电网暂态输送200 MVA以上的无功,对电网电压的暂停稳定有重要的支撑作用。展开更多
为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局...为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。展开更多
基金Supported by China Postdoctoral Science Foundation(20090460873)
文摘In view of the serious reactive power loss in the rural network, improved ant colony optimization algorithm (ACOA) was used to optimize the reactive power compensation for the rural distribution system. In this study, the traditional ACOA was improved in two aspects: one was the local search strategy, and the other was pheromone mutation and re-initialization strategies. The reactive power optimization for a county's distribution network showed that the improved ACOA was practicable.
文摘为研究南方电网500 k V东莞站首个链式35 k V±200 MVA STATCOM在各种主网故障情况下暂态响应的能力和情况,理论计算了500 k V东莞站附近主要枢纽变电站短路故障对其220 k V母线电压的影响;在PSCAD/EMTDC仿真平台上编写了数据处理程序,根据STATCOM投运3 a来500 k V东莞站及周边强联系的枢纽变电站发生典型的、严重接地短路或者相间短路故障的运行数据,对STATCOM的响应情况进行深入分析,验证了STATCOM的进入和退出暂态的条件及策略的正确性;计算了STATCOM在系统电压暂降时实际对电网无功支撑量;结果表明STATCOM能在20 ms内正确响应,为电网暂态输送200 MVA以上的无功,对电网电压的暂停稳定有重要的支撑作用。
文摘为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。
文摘针对静止同步补偿器(static synchronous compensator,STATCOM)在无功补偿以及抑制电压频繁波动等场景下的优良特性,对STATCOM的V-I输出特性进行详细分析,说明其参与电压控制的原理以及和容抗器相比具有的优越性。为了增大STATCOM的无功裕度,使之有足够的能力应对电力系统可能出现的各种扰动,提出STATCOM接入系统的各种控制模式,以及在稳态电压控制模式下的无功置换策略和远方自动电压控制(automatic voltage control,AVC)模式下的无功置换优化方法。在远方AVC模式下,以STATCOM无功置换后出力最小和容抗器动作次数最少为目标函数,将容抗器投切次数作为罚函数引入到目标函数中,并讨论罚函数系数的确定方法和合理性。结果表明,该无功置换优化模型可以满足调压的同时最大限度地提升STATCOM的无功裕度,同时可以使容抗器的动作次数最少。