We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup t...We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup tower is 181 m with a ground elevation of 47 m, which makes it a super flexible and wind-sensitive structure. Therefore, we should analyze the wind- resistant capacity of the system. We simulated applicable transverse fluctuating wind velocity field, developed a lead-rubber damper (LRD) for controlling wind-induced vibration of long-span transmission towers, deduced LRD calculation model parameter, and researched the best layout scheme and installation method of LRD. To calculate the wind-induced response of tower-line coupling system in seven layout schemes, we used the time history analysis method, and obtained the efficiencies of wind-induced vibration control. LRD deformation research proved that the damp of all LRDs was efficient under the designed wind velocity when they were laid along the edge of tower heads. We studied the controlling efficiency resulting fTom only applying stiffness to the tower polos where the dampers used to be laid under the designed wind velocity. The results show that the controlling efficiency was not ideal when the stiffness is increased on the poles only. Therefore, LRD should conlxibute to both the stiffness and damp of a structure to effectively reduce the dynamic response of a tower-line coupling system under strong winds. We also discussed the controlling efficiency of LRD under static winds. The results show that there was little difference between displacements derived by the finite clement time history method and those obtained by static wind method conducted by a design institute. This means the simulation on space relevant wind velocity field was accurate and reasonable.展开更多
As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields ...As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.展开更多
Stay cables with various surface profiles were tested in wind tunnel. Dimples and helical fillets were applied to mitigate the rain- wind induced vibration. The rain-wind excited responses of the cable with smooth sur...Stay cables with various surface profiles were tested in wind tunnel. Dimples and helical fillets were applied to mitigate the rain- wind induced vibration. The rain-wind excited responses of the cable with smooth surface were larger than those of the cables with dimples and helical fillets. At high Reynolds number, the drag coefficients of cables with dimples and helical fillets are much larger than those of smooth surface cable.展开更多
Vortex-induced vibration is likely to occur when subjected to wind loads because of low horizontal stiffness,resulting in internal force and large lateral amplitude.Long-term wind-induced vibration can not only affect...Vortex-induced vibration is likely to occur when subjected to wind loads because of low horizontal stiffness,resulting in internal force and large lateral amplitude.Long-term wind-induced vibration can not only affect the normal service and durability performance of chemical towers,but also seriously endanger the safety of towers in service periods,and cause property losses.In this study,a passive control method for suppressing wind-induced vibration of chemical towers is proposed.The flow around the flow field is guided by a pre-set air-blowing channel,thus destroying the unsteady vortex shedding in the wake region of the flow field and achieving the purpose of flow control.Two accelerometers are used to measure the vibration signal of the chemical tower model with and without the perforated pipe.The control effects of the spacing and the installation position of the perforated pipe are then studied.Experimental results show that the passive perforated pipe control method can effectively reduce the vibration amplitude of the chemical tower under wind loads,and decrease the potential wind-induced vibration.展开更多
To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and for...To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and force response of the tower was calculated and analyzed. The results show that the control effect of lead viscoelastic dampers is very good, and the damping ratio can reach 20% or more when they are applied to the tower head.展开更多
基金Funded by the Science and Technology Research Project of the State Grid Corporation (No. [2007]413)
文摘We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup tower is 181 m with a ground elevation of 47 m, which makes it a super flexible and wind-sensitive structure. Therefore, we should analyze the wind- resistant capacity of the system. We simulated applicable transverse fluctuating wind velocity field, developed a lead-rubber damper (LRD) for controlling wind-induced vibration of long-span transmission towers, deduced LRD calculation model parameter, and researched the best layout scheme and installation method of LRD. To calculate the wind-induced response of tower-line coupling system in seven layout schemes, we used the time history analysis method, and obtained the efficiencies of wind-induced vibration control. LRD deformation research proved that the damp of all LRDs was efficient under the designed wind velocity when they were laid along the edge of tower heads. We studied the controlling efficiency resulting fTom only applying stiffness to the tower polos where the dampers used to be laid under the designed wind velocity. The results show that the controlling efficiency was not ideal when the stiffness is increased on the poles only. Therefore, LRD should conlxibute to both the stiffness and damp of a structure to effectively reduce the dynamic response of a tower-line coupling system under strong winds. We also discussed the controlling efficiency of LRD under static winds. The results show that there was little difference between displacements derived by the finite clement time history method and those obtained by static wind method conducted by a design institute. This means the simulation on space relevant wind velocity field was accurate and reasonable.
基金supported by the National Key Research and Development Program of China (Nos. 2018YFC0809600,2018YFC0809604)the National Natural Science Foundation of China(No.51678451).
文摘As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.
文摘Stay cables with various surface profiles were tested in wind tunnel. Dimples and helical fillets were applied to mitigate the rain- wind induced vibration. The rain-wind excited responses of the cable with smooth surface were larger than those of the cables with dimples and helical fillets. At high Reynolds number, the drag coefficients of cables with dimples and helical fillets are much larger than those of smooth surface cable.
基金This work was supported by the National Natural Science Foundation of China(Nos.51578188,51722805,51378153 and 51808173)the Fundamental Research Funds for Central Universities(HIT.BRETIII.201512,HIT.BRETIV.201803 and HIT.NSRIF.201862).
文摘Vortex-induced vibration is likely to occur when subjected to wind loads because of low horizontal stiffness,resulting in internal force and large lateral amplitude.Long-term wind-induced vibration can not only affect the normal service and durability performance of chemical towers,but also seriously endanger the safety of towers in service periods,and cause property losses.In this study,a passive control method for suppressing wind-induced vibration of chemical towers is proposed.The flow around the flow field is guided by a pre-set air-blowing channel,thus destroying the unsteady vortex shedding in the wake region of the flow field and achieving the purpose of flow control.Two accelerometers are used to measure the vibration signal of the chemical tower model with and without the perforated pipe.The control effects of the spacing and the installation position of the perforated pipe are then studied.Experimental results show that the passive perforated pipe control method can effectively reduce the vibration amplitude of the chemical tower under wind loads,and decrease the potential wind-induced vibration.
基金Research Fund of Chinese State Grid Company (No.SGKJ[2007]413)
文摘To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and force response of the tower was calculated and analyzed. The results show that the control effect of lead viscoelastic dampers is very good, and the damping ratio can reach 20% or more when they are applied to the tower head.