The pull-out capacities for soil nailing systems comprising of one single 29 mm diameter(type A) and four 16 mm diameter(type B) rebars with grouted cement were examined.A field test and numerical analysis for the typ...The pull-out capacities for soil nailing systems comprising of one single 29 mm diameter(type A) and four 16 mm diameter(type B) rebars with grouted cement were examined.A field test and numerical analysis for the type A and type B systems were carried out to investigate the pull-out capacities and the slope stability reinforcement efficiency in soil and rock slopes.The results of the pull-out tests show the mobilized shear force and load transfer characteristics with respect to soil depth.The load-displacement relationship was examined for both type A and type B systems.Slope stability analyses were carried out to study the relationships between soil and nail reinforcement and bending stiffness as well as combined axial tension and shear forces.Factors of safety were calculated in relation to the number of nails and their outside diameters.Both soil and rock slopes were included in this evaluation.展开更多
Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of...Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of laboratory pull-out tests were conducted to comprehensively investigate the effects of different pull-out loading rates on the mechanical performance and failure characteristics of fully grouted bolts.The results show that the mechanical performance of the anchored specimen presents obvious loading rate dependence and shear enhancement characteristics.With the increase of the pull-out loading rates,the maximum pull-out load increases,the displacement and time corresponding to the maximum pull-out load decrease.The accumulated acoustic emission(AE)counts,AE energy and AE events all decrease with the increase of the pull-out loading rates.The AE peak frequency has obvious divisional distribution characteristics and the amplitude is mainly distributed between 50-80 dB.With the increase of the pull-out loading rates,the local strain of the anchoring interface increases and the failure of the anchoring interface transfers to the interior of the resin grout.The accumulated AE counts are used to evaluate the damage parameter of the anchoring interface during the whole pull-out process.The analytical results are in good agreement with the experimental results.The research results may provide guidance for the support design and performance monitoring of fully grouted bolts.展开更多
Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)...Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)after fatigue resistance testing at different cycles and semidiameter of screw insertion area of micro-CT image was compared between the micro-dynamic and traditional pedicle screws.Methods Forty lumbar vertebrae received a traditional pedicle screw on one side and a micro-dynamic pedicle screw on the other side as follows:15 vertebrae underwent instant pull-out testing(group A,traditional vs.group B,micro-dynamic);15 vertebrae underwent pull-out test after 5000-cyclic fatigue loading(group C,traditional vs.group D,micro-dynamic);and 10 vertebrae underwent pull-out test after 10000-cyclic fatigue loading(group E,traditional vs.group F,micro-dynamic).All vertebrae that after fatigue loading were scanned by using micro-ct to check the semidiameter of screw insertion area.The PPF,normalized PPF(PPFn),bone mineral density(BMD)and diameter of screw insertion area were compared between all groups.Results The BMD showed a weak significant correlation with PPF(r=0.252,P=0.024).The PPF in groups A and B(P=0.485),and groups C and D(P=0.184)did not show significant difference.However,the PPF in group F was significantly greater than that measured in group E(P=0.005).The PPFn of groups A,C,and E significantly decreased as the number of cycles increased(P=0.015).Meanwhile,the PPFn of groups B,D,and F remained consistent regardless of the number of cycles(P=0.367). The semidiameter of traditional pedicle screw insertion area was significantly larger than that of micro-dynamic pedicle screw insertion area(P<0.001).Conclusions This study compared the performance of a micro-dynamic pedicle screw versus that of a traditional pedicle screw using pull-out testing and micro-CT.The results showed that the micro-dynamic pedicle screw provides similar resistance in lowcycle fatigue testing and favorable resistance in high-cycle fatigue testing versus the traditional pedicle screw.The micro-dynamic pedicle screw provides stronger fixation stability versus the traditional pedicle screw,especially in high-cyclic fatigue loading condition versus the traditional pedicle screws.展开更多
文摘The pull-out capacities for soil nailing systems comprising of one single 29 mm diameter(type A) and four 16 mm diameter(type B) rebars with grouted cement were examined.A field test and numerical analysis for the type A and type B systems were carried out to investigate the pull-out capacities and the slope stability reinforcement efficiency in soil and rock slopes.The results of the pull-out tests show the mobilized shear force and load transfer characteristics with respect to soil depth.The load-displacement relationship was examined for both type A and type B systems.Slope stability analyses were carried out to study the relationships between soil and nail reinforcement and bending stiffness as well as combined axial tension and shear forces.Factors of safety were calculated in relation to the number of nails and their outside diameters.Both soil and rock slopes were included in this evaluation.
基金Projects(51925402,U1710258,52004172)supported by the National Natural Science Foundation of ChinaProject(20201102004)supported by the Science and Technology Department of Shanxi Province,China。
文摘Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of laboratory pull-out tests were conducted to comprehensively investigate the effects of different pull-out loading rates on the mechanical performance and failure characteristics of fully grouted bolts.The results show that the mechanical performance of the anchored specimen presents obvious loading rate dependence and shear enhancement characteristics.With the increase of the pull-out loading rates,the maximum pull-out load increases,the displacement and time corresponding to the maximum pull-out load decrease.The accumulated acoustic emission(AE)counts,AE energy and AE events all decrease with the increase of the pull-out loading rates.The AE peak frequency has obvious divisional distribution characteristics and the amplitude is mainly distributed between 50-80 dB.With the increase of the pull-out loading rates,the local strain of the anchoring interface increases and the failure of the anchoring interface transfers to the interior of the resin grout.The accumulated AE counts are used to evaluate the damage parameter of the anchoring interface during the whole pull-out process.The analytical results are in good agreement with the experimental results.The research results may provide guidance for the support design and performance monitoring of fully grouted bolts.
基金supported by the National Natural Science Foundation of China ( 31670957)
文摘Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)after fatigue resistance testing at different cycles and semidiameter of screw insertion area of micro-CT image was compared between the micro-dynamic and traditional pedicle screws.Methods Forty lumbar vertebrae received a traditional pedicle screw on one side and a micro-dynamic pedicle screw on the other side as follows:15 vertebrae underwent instant pull-out testing(group A,traditional vs.group B,micro-dynamic);15 vertebrae underwent pull-out test after 5000-cyclic fatigue loading(group C,traditional vs.group D,micro-dynamic);and 10 vertebrae underwent pull-out test after 10000-cyclic fatigue loading(group E,traditional vs.group F,micro-dynamic).All vertebrae that after fatigue loading were scanned by using micro-ct to check the semidiameter of screw insertion area.The PPF,normalized PPF(PPFn),bone mineral density(BMD)and diameter of screw insertion area were compared between all groups.Results The BMD showed a weak significant correlation with PPF(r=0.252,P=0.024).The PPF in groups A and B(P=0.485),and groups C and D(P=0.184)did not show significant difference.However,the PPF in group F was significantly greater than that measured in group E(P=0.005).The PPFn of groups A,C,and E significantly decreased as the number of cycles increased(P=0.015).Meanwhile,the PPFn of groups B,D,and F remained consistent regardless of the number of cycles(P=0.367). The semidiameter of traditional pedicle screw insertion area was significantly larger than that of micro-dynamic pedicle screw insertion area(P<0.001).Conclusions This study compared the performance of a micro-dynamic pedicle screw versus that of a traditional pedicle screw using pull-out testing and micro-CT.The results showed that the micro-dynamic pedicle screw provides similar resistance in lowcycle fatigue testing and favorable resistance in high-cycle fatigue testing versus the traditional pedicle screw.The micro-dynamic pedicle screw provides stronger fixation stability versus the traditional pedicle screw,especially in high-cyclic fatigue loading condition versus the traditional pedicle screws.