An intelligent power factor correction scheme is presented for three phase low power factor loads. This new scheme is able to perform individual phase sensing of parameters by monitoring at all times to sense a change...An intelligent power factor correction scheme is presented for three phase low power factor loads. This new scheme is able to perform individual phase sensing of parameters by monitoring at all times to sense a change in system parameters and affects individual phase correction by applying the exact amount of reactive components needed for each phase, and can also reduce negative sequence current caused by the load to improve system balance. An optimization criterion is used for the proper calculation of reactive power steps in a power compensation installation of capacitor banks. The criterion is enabled by sampling measurements performed on the electrical plant examined within specific interval of time.展开更多
Based on a neutral point diode clamped eight-switch configuration, a general mathematical model of single phase bi-directional three-level (TL) rectifiers is built by proposing two equivalent TL arms for topology deri...Based on a neutral point diode clamped eight-switch configuration, a general mathematical model of single phase bi-directional three-level (TL) rectifiers is built by proposing two equivalent TL arms for topology derivation. A series of TL rectifiers are derived by using double TL and multi TL methods, and their characteristics are compared at the same time. A novel seven-switch double TL rectifier is constructed, and its operational principle and control algorithm are illustrated as well. Lastly, its waveform and harmonic spectrum are compared to those of multi TL rectifiers, and the adopted rectifier gains better performance and unit PF.展开更多
文摘An intelligent power factor correction scheme is presented for three phase low power factor loads. This new scheme is able to perform individual phase sensing of parameters by monitoring at all times to sense a change in system parameters and affects individual phase correction by applying the exact amount of reactive components needed for each phase, and can also reduce negative sequence current caused by the load to improve system balance. An optimization criterion is used for the proper calculation of reactive power steps in a power compensation installation of capacitor banks. The criterion is enabled by sampling measurements performed on the electrical plant examined within specific interval of time.
基金National Nature Science Foundation of China(50277017)
文摘Based on a neutral point diode clamped eight-switch configuration, a general mathematical model of single phase bi-directional three-level (TL) rectifiers is built by proposing two equivalent TL arms for topology derivation. A series of TL rectifiers are derived by using double TL and multi TL methods, and their characteristics are compared at the same time. A novel seven-switch double TL rectifier is constructed, and its operational principle and control algorithm are illustrated as well. Lastly, its waveform and harmonic spectrum are compared to those of multi TL rectifiers, and the adopted rectifier gains better performance and unit PF.