This article introduces a string of energy conservation measures adopted over the past sev- eral years by the RFCC unit at Shengli Petrochemical Complex, including the optimization of feedstock properties, the adoptio...This article introduces a string of energy conservation measures adopted over the past sev- eral years by the RFCC unit at Shengli Petrochemical Complex, including the optimization of feedstock properties, the adoption of high-efficiency atomizing nozzles, the revamp of CO boiler, the atomization by means of dry gas, the post-burning of flue gas as well as the application of frequency converting machines and pumps, resulting in ideal effects. The energy consumption of the RFCC unit was gradually decreased to 2984.25 MJ/t from the original level of 3716.99 MJ/t. After comparing basic energy con- sumption values with actual consumption values, the authors have set forward measures for further energy conservation, such as the recovery of low-temperature excess heat contained in oil/gas streams exiting from the fractionation tower top, addition of the fourth cyclone, delivery of hot oil slurry, and heat tracing with hot water.展开更多
基于超声波时差测量流量的方法具有非接触、易安装、不改变流体的运动状态等优点,被广泛应用于油田井下流体流速测量分析领域,能够实时测量流体流速,准确分析管道中流体流量的变化。针对传统的超声波流量计功耗高、电路复杂的缺点,根据...基于超声波时差测量流量的方法具有非接触、易安装、不改变流体的运动状态等优点,被广泛应用于油田井下流体流速测量分析领域,能够实时测量流体流速,准确分析管道中流体流量的变化。针对传统的超声波流量计功耗高、电路复杂的缺点,根据超声波时差法测量流量的原理,结合井下高温测量环境,以及未来测井仪器低功耗、小型化的需求,以dsPIC33EV为主控芯片,设计了一种低功耗、小型化的井下超声波流量测量系统。该系统利用dsPIC33EV的充电时间测量单元CTMU(Charging Time Measurement Unit),实现声波传播时差与流量的高精度测量与计算。室内实验平台测试数据表明,该文设计的井下超声波流量测量系统测量相对误差为±7.2%,典型功耗为20mW,技术指标满足生产井流量监测需求。展开更多
文摘This article introduces a string of energy conservation measures adopted over the past sev- eral years by the RFCC unit at Shengli Petrochemical Complex, including the optimization of feedstock properties, the adoption of high-efficiency atomizing nozzles, the revamp of CO boiler, the atomization by means of dry gas, the post-burning of flue gas as well as the application of frequency converting machines and pumps, resulting in ideal effects. The energy consumption of the RFCC unit was gradually decreased to 2984.25 MJ/t from the original level of 3716.99 MJ/t. After comparing basic energy con- sumption values with actual consumption values, the authors have set forward measures for further energy conservation, such as the recovery of low-temperature excess heat contained in oil/gas streams exiting from the fractionation tower top, addition of the fourth cyclone, delivery of hot oil slurry, and heat tracing with hot water.
文摘基于超声波时差测量流量的方法具有非接触、易安装、不改变流体的运动状态等优点,被广泛应用于油田井下流体流速测量分析领域,能够实时测量流体流速,准确分析管道中流体流量的变化。针对传统的超声波流量计功耗高、电路复杂的缺点,根据超声波时差法测量流量的原理,结合井下高温测量环境,以及未来测井仪器低功耗、小型化的需求,以dsPIC33EV为主控芯片,设计了一种低功耗、小型化的井下超声波流量测量系统。该系统利用dsPIC33EV的充电时间测量单元CTMU(Charging Time Measurement Unit),实现声波传播时差与流量的高精度测量与计算。室内实验平台测试数据表明,该文设计的井下超声波流量测量系统测量相对误差为±7.2%,典型功耗为20mW,技术指标满足生产井流量监测需求。