期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Elemental and proximate analysis of coal by x-ray fluorescence assisted laser-induced breakdown spectroscopy 被引量:5
1
作者 Zhihui TIAN Xiaolin LI +9 位作者 Gang WANG Lei ZHANG Jiaxuan LI Shuqing WANG Yu BAI Wanfei ZHANG Han YUE Xiaofei MA Wangbao YIN Suotang JIA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第8期55-63,共9页
Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in therm... Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) x-ray fluorescence spectrometry(XRF) high repeatability measurement spectral calibration instability analysis
在线阅读 下载PDF
A TOTAL CONTENT X—RAY FLUORESCENCE METHOD FOR COPPER PROSPECTING
2
作者 周四春 谢庭周 葛良全 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第3期191-195,共5页
A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of... A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of a Cu deposit. Applications of the technique in Northeast China are presented. 展开更多
关键词 portable x-ray fluorescence ANALYZERS Total content x-ray fluorescence method PROSPECTING for COPPER DEPOSITS
在线阅读 下载PDF
A method for correcting characteristic X-ray net peak count from drifted shadow peak 被引量:2
3
作者 Lin Tang Xing‑Ke Ma +2 位作者 Kai‑Bo Shi Yeng‑Chai Soh Hong‑Tao Shen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第11期155-167,共13页
To correct spectral peak drift and obtain more reliable net counts,this study proposes a long short-term memory(LSTM)model fused with a convolutional neural network(CNN)to accurately estimate the relevant parameters o... To correct spectral peak drift and obtain more reliable net counts,this study proposes a long short-term memory(LSTM)model fused with a convolutional neural network(CNN)to accurately estimate the relevant parameters of a nuclear pulse signal by learning of samples.A predefined mathematical model was used to train the CNN-LSTM model and generate a dataset composed of distorted pulse sequences.The trained model was validated using simulated pulses.The relative errors in the amplitude estimation of pulse sequences with different degrees of distortion were obtained using triangular shaping,CNN-LSTM,and LSTM models.As a result,for severely distorted pulses,the relative error of the CNN-LSTM model in estimating the pulse parameters was reduced by 14.35%compared with that of the triangular shaping algorithm.For slightly distorted pulses,the relative error of the CNN-LSTM model was reduced by 0.33%compared with that of the triangular shaping algorithm.The model was then evaluated considering two performance indicators,the correction ratio and the efficiency ratio,which represent the proportion of the increase in peak area of the two characteristic peak regions of interest(ROIs)to the peak area of the corrected characteristic peak ROI and the proportion of the increase in peak area of the two characteristic peak ROIs to the peak areas of the two shadow peak ROI,respectively.Ten measurement results of the iron ore samples indicate that approximately 86.27%of the decreased peak area of the shadow peak ROI was corrected to the characteristic peak ROI,and the proportion of the corrected peak area to the peak area of the characteristic peak ROI was approximately 1.72%.The proposed CNN-LSTM model can be applied to X-ray energy spectrum correction,which is of great significance for X-ray spectroscopy and elemental content analyses. 展开更多
关键词 Peak correction Triangular shaping Deep learning Long short-term memory Convolutional neural network x-ray fluorescence spectroscopy Silicon drift detector
在线阅读 下载PDF
基于便携式X射线荧光光谱速测的设施菜地土壤重金属污染诊断与评价 被引量:3
4
作者 邓源 樊亚男 +7 位作者 吴秋梅 胡文友 俞越明 王华 朱春梧 李汛 田康 黄标 《土壤学报》 CAS CSCD 北大核心 2024年第1期174-186,共13页
土壤重金属污染快速诊断与评价是污染防控与风险管理的前提。以广东省典型设施蔬菜产地土壤为研究对象,采用便携式X射线荧光光谱法(portable X-ray fluorescence spectroscopy,PXRF)原位快速获取土壤重金属(镉(Cd)、铜(Cu)、铬(Cr)、铅(... 土壤重金属污染快速诊断与评价是污染防控与风险管理的前提。以广东省典型设施蔬菜产地土壤为研究对象,采用便携式X射线荧光光谱法(portable X-ray fluorescence spectroscopy,PXRF)原位快速获取土壤重金属(镉(Cd)、铜(Cu)、铬(Cr)、铅(Pb)、锌(Zn)、砷(As)、镍(Ni)及汞(Hg))含量,在传统实验室方法验证PXRF的准确性和稳定性的基础上,对广东省设施菜地表层土壤重金属的污染状况进行快速诊断,并对土壤重金属污染风险进行评价。结果表明:(1)异位PXRF法对土壤Cd、Cu、Cr、Pb、Zn、As及Ni的测定值与传统实验室方法测定值极显著相关(P<0.01),土壤Pb和As含量的PXRF原位测定值与传统实验室方法测定值极显著相关(P<0.01);(2)土壤含水量为150 g·kg^(-1)~200 g·kg^(-1)时,Cr、Pb、Zn和As的PXRF原位测定值与实验室测定值的相关性达到了极显著水平(P<0.01);(3)土壤Cd和Cu的超标现象较为突出,其点位超标率分别为20.9%和10.0%。设施菜地土壤Cd的平均含量为0.21 mg·kg^(-1),约为露天农田土壤的1.2倍。珠江三角洲地区设施土壤中各重金属的含量整体较其他地区高;(4)土壤Cd、Cu、Cr、Pb、Zn、As、Ni及Hg的单项污染指数均小于1,由高到低依次为Cd>Cu>Pb>Zn>Cr>As>Ni>Hg,内梅罗综合污染指数的均值为0.69。就整体平均值而言,土壤重金属污染程度处于清洁水平。PXRF实现了广东省设施菜地土壤重金属污染的快速诊断,并快速识别出Cd和Cu为设施菜地污染风险较高的潜在污染元素,研究结果可为设施农业土壤重金属污染快速诊断与评价提供方法和数据支撑。 展开更多
关键词 便携式X射线荧光光谱法 设施农业 快速检测 空间分布 风险评价
在线阅读 下载PDF
土壤重金属检测方法研究 被引量:2
5
作者 沙淑莉 肖霄 +5 位作者 刘兰 朱亭亭 韩学静 吴永强 周冠霖 于宏伟 《煤炭与化工》 CAS 2022年第9期133-139,共7页
随着我国现代工业化进程的快速推进,重金属(如锌、铜、镉、铬、镍、铅、锰和钴)污染对农田土壤造成了危害,并通过食物链对人类健康造成了威胁。介绍了国内外土壤重金属检测的常用方法,如便携式X射线荧光光谱(PXRF)、原子吸收光谱(AAS)... 随着我国现代工业化进程的快速推进,重金属(如锌、铜、镉、铬、镍、铅、锰和钴)污染对农田土壤造成了危害,并通过食物链对人类健康造成了威胁。介绍了国内外土壤重金属检测的常用方法,如便携式X射线荧光光谱(PXRF)、原子吸收光谱(AAS)、电感耦合等离子体-质谱(ICP-MS)、电感耦合等离子体发射光谱(ICP-OES)及红外光谱(IR)法。重点阐述了各检测方法的优缺点,为农田土壤中重金属检测方法提供技术参考。 展开更多
关键词 重金属 便携式X射线荧光光谱 原子吸收光谱 电感耦合等离子体-质谱 电感耦合等离子体发射光谱 红外光谱
在线阅读 下载PDF
Synthesis of SiC/graphene nanosheet composites by helicon wave plasma
6
作者 Jia-Li Chen Pei-Yu Ji +2 位作者 Cheng-Gang Jin Lan-Jian Zhuge Xue-Mei Wu 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第7期339-344,共6页
We report an approach to the rapid, one-step, preparation of a variety of wide-bandgap silicon carbide/graphene nanosheet(Si C/GNSs) composites by using a high-density helicon wave plasma(HWP) source. The microstructu... We report an approach to the rapid, one-step, preparation of a variety of wide-bandgap silicon carbide/graphene nanosheet(Si C/GNSs) composites by using a high-density helicon wave plasma(HWP) source. The microstructure and morphology of the Si C/GNSs are characterized by using scanning electron microscopy(SEM), Raman spectroscopy, x-ray diffraction(XRD), x-ray photoelectron spectroscopy(XPS), and fluorescence(PL). The nucleation mechanism and the growth model are discussed. The existence of Si C and graphene structure are confirmed by XRD and Raman spectra.The electron excitation temperature is calculated by the intensity ratio method of optical emission spectroscopy. The main peak in the PL test is observed at 420 nm, with a corresponding bandgap of 2.95 e V that indicates the potential for broad application in blue light emission and ultraviolet light emission, field electron emission, and display devices. 展开更多
关键词 helicon wave plasma SiC/graphene nanosheet x-ray photoelectron spectroscopy(XPS) fluorescence
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部