Determination of Residues and Safety Analysis of Metal Impurities in Platinum-based Antitumor Drugs
1
作者 PENG Juan PU Shaoping +3 位作者 LI Guangli HE Jian ZHANG Zhirong LIAO Yunxing 《贵金属》 CAS CSCD 北大核心 2012年第A01期258-262,共5页
The residual metal impurities in cisplatin, carboplatin and oxaliplatin were determined by ICP-AES. The samples were ignited and dissolved with HCl:HNO 3 (3:1). The method is simple and accurate. By the determination ... The residual metal impurities in cisplatin, carboplatin and oxaliplatin were determined by ICP-AES. The samples were ignited and dissolved with HCl:HNO 3 (3:1). The method is simple and accurate. By the determination of the metal residues in the samples, the calculated actual daily exposure and concentration of the metal Pd, Ir, Rh, Ru, Mo, Ni, Cr, V, Cu, Mn, Fe and Zn that were less than the permitted daily exposures (PDE) and the limited concentration permitted in the EMEA guideline on the specification limits for residues of metal catalysts or metal reagents [1] . The metal residues can de adequately removed from the active pharmaceutical ingredients and the corresponding drugs. The trace metal residues will not affect human health and lead to the safety hazard by the intravenous injection. 展开更多
关键词 ICP-AES platinum-based antitumor drug metal reagent residue safety
在线阅读 下载PDF
HPLC Method Research of Picoplatin-a New Platinum Anti-cancer Drug and Its Impurities 被引量:1
2
作者 LUAN Chunfang CONG Yanwei +3 位作者 ZHANG Qi QIU Xueweng BEI Yuxiang PU Shaoping 《贵金属》 CAS CSCD 北大核心 2012年第A01期253-257,共5页
Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mm×250 mm, 5 m) with potassium dihydrogen phosphate-aceton-... Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mm×250 mm, 5 m) with potassium dihydrogen phosphate-aceton-itrile as the mobile phase at a flow rate of 1.0 mL/min. The detecting wavelength was set at 210 nm, and the column temperature was set at 30℃. Result: in the method validation, the linear relationship modulus of picoplatin is 0.9999, the systemic precision is 0.44%, the method precision is 0.74%, the average recovery rate is 99.62%, the LOD and LOQ of picoplatin is 0.2 ng and 1.0 ng. The average resolution of picoplatin and its impurities is more than 2. Conclusion: The established method is good specificity, high sensitivity, and good repeatability which could provide scientific evidence for the quality control of picoplatin and its impurities. 展开更多
关键词 platinum-based anti-cancer drug picoplatin HPLC
在线阅读 下载PDF