期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Novel Manufacturing Technology of Hyperbolic Plates for Shipbuilding 被引量:6
1
作者 ZHANG Xu , ZHANG Jia-tai , LIU Gang, YUAN S J, WANG Z R College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin, 150001, China College of Material Science and Engineering, Harbin Institute of Technology, Harbin , 150001 , China 《Journal of Marine Science and Application》 2002年第1期77-80,共4页
On the basis of the principle of dieless hydrobulging technology, a novel hydrobulging technology for manufacturinghyperbolic plates is proposed. First, a toroidal pipe elbow or a partial toroidal pipe elbow is formed... On the basis of the principle of dieless hydrobulging technology, a novel hydrobulging technology for manufacturinghyperbolic plates is proposed. First, a toroidal pipe elbow or a partial toroidal pipe elbow is formed, then the single hydrobulgedstructure can be cut up into some desired plates. It is proved by experiments and finite element simulation that manufacturingtechnology of hyperbolic plates adopting integrated hydrobulging forming technology is feasible. 展开更多
关键词 hyperbolic plates integrally hydrobulging toroidal pipe elbow partial toroidal pipe elbow
在线阅读 下载PDF
Flow-induced Noise and Vibration Analysis of a Piping Elbow with/without a Guide Vane 被引量:4
2
作者 Tao Zhang Yong'ou Zhang +1 位作者 Huajiang Ouyang Tao Guo 《Journal of Marine Science and Application》 2014年第4期394-401,共8页
The effect of a guide vane installed at the elbow on flow-induced noise and vibration is investigated in the range of Reynolds numbers from 1.70×10^5 to 6.81×10^5, and the position of guide vane is determine... The effect of a guide vane installed at the elbow on flow-induced noise and vibration is investigated in the range of Reynolds numbers from 1.70×10^5 to 6.81×10^5, and the position of guide vane is determined by publications. The turbulent flow in the piping elbow is simulated with large eddy simulation (LES). Following this, a hybrid method of combining LES and Lighthill's acoustic analogy theory is used to simulate the hydrodynamic noise and sound sources are solved as volume sources in code Actran. In addition, the flow-induced vibration of the piping elbow is investigated based on a fluid-structure interaction (FSI) code. The LES results indicate that the range of vortex zone in the elbow without the guide vane is larger than the case with the guide vane, and the guide vane is effective in reducing flow-induced noise and vibration in the 90° piping elbow at different Reynolds numbers. 展开更多
关键词 flow-induced noise flow-induced vibration piping elbow guide vane large eddy simulation fluid structure interaction Actran
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部