There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw...There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.展开更多
The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using th...The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using the autoclam permeability system. The air permeability, sorptivity and water permeability indexes of No.1 PCCB are smaller than or equal to 0.11 ln(102 Pa)/min, 0.98×10 ^7 m3/minl/2 and 1.93×10 ^7 m3/min1/2, respectively, and the air permeability, sorptivity and water permeability indexes of No.2 PCCB are smaller than or equal to 0.17 In(102 Pa)/min, 1.6×10 ^7 m3/min1/2 and 4.43 ×10 ^7 m3/min1/2, respectively. Based on the criteria for evaluating the protective quality of concrete structures in terms of their permeability and sorptivity properties, proposed by the research organization of the autoclam permeability system, the protective quality of No. 1 PCCB is still in very good grade and that of No.2 PCCB is not in very good grade but in good grade, and the in-service inspection of the protective quality of No.2 PCCB should be strengthened in the future.展开更多
基金Key Project of National Natural Science Foundation of China(52237008)Beijing Municipal Education Commission Research Program Funding Project(KM202111232022)。
文摘There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.
基金Project(20050487017) supported by the Specialized Research Fund for the Doctoral Program of Higher Education of ChinaProject (2009567) supported by China National Nuclear Corporation
文摘The permeability and sorptivity properties of the two prestressed concrete containment buildings (PCCBs) of a nuclear power plant in South China, which had been under operation for 5 years, were measured by using the autoclam permeability system. The air permeability, sorptivity and water permeability indexes of No.1 PCCB are smaller than or equal to 0.11 ln(102 Pa)/min, 0.98×10 ^7 m3/minl/2 and 1.93×10 ^7 m3/min1/2, respectively, and the air permeability, sorptivity and water permeability indexes of No.2 PCCB are smaller than or equal to 0.17 In(102 Pa)/min, 1.6×10 ^7 m3/min1/2 and 4.43 ×10 ^7 m3/min1/2, respectively. Based on the criteria for evaluating the protective quality of concrete structures in terms of their permeability and sorptivity properties, proposed by the research organization of the autoclam permeability system, the protective quality of No. 1 PCCB is still in very good grade and that of No.2 PCCB is not in very good grade but in good grade, and the in-service inspection of the protective quality of No.2 PCCB should be strengthened in the future.