Efficiency and linearity of the microwave power amplifier are critical elements for mobile communication systems. A memory polynomial baseband predistorter based on an indirect learning architecture is presented for i...Efficiency and linearity of the microwave power amplifier are critical elements for mobile communication systems. A memory polynomial baseband predistorter based on an indirect learning architecture is presented for improving the linearity of an envelope tracing (ET) amplifier with application to a wireless transmitter. To deal with large peak-to-average ratio (PAR) problem, a clipping procedure for the input signal is employed. Then the system performance is verified by simulation results. For a single carrier wideband code division multiple access (WCDMA) signal of 16-quadrature amplitude modulation (16-QAM), about 2% improvement of the error vector magnitude (EVM) is achieved at an average output power of 45.5 dBm and gain of 10.6 dB, with adjacent channel leakage ratio (ACLR) of -64.55 dBc at offset frequency of 5 MHz. Moreover, a three-carrier WCDMA signal and a third-generation (3G) long term evolution (LTE) signal are used as test signals to demonstrate the performance of the proposed linearization scheme under different bandwidth signals.展开更多
Constant envelope with a fractional Fourier transformorthogonal frequency division multiplexing(CE-FrFT-OFDM)is a special case of a constant envelope OFDM(CE-OFDM),both being energy efficient wireless communication te...Constant envelope with a fractional Fourier transformorthogonal frequency division multiplexing(CE-FrFT-OFDM)is a special case of a constant envelope OFDM(CE-OFDM),both being energy efficient wireless communication techniques with a 0 dB peak to average power ratio(PAPR).However,with the proper selection of fractional order,the first technique has a high bit error rate(BER)performance in the frequency-time selective channels.This paper performs further analysis of CE-FrFT-OFDM by examining its spectral efficiency(SE)and energy efficiency(EE)and compare to the famous OFDM and FrFT-OFDM techniques.Analytical and comprehensive simulations conducted show that,the CE-FrFT-OFDM has five times the EE of OFDM and FrFT-OFDM systems with a slightly less SE.Increasing CE-FrFT-OFDM’s transmission power by increasing its amplitude to 1.7 increases its SE to match that of the OFDM and FrFT-OFDM systems while slightly reducing its EE by 20%to be four times that of OFDM and FrFTOFDM systems.OFDM and FrFT-OFDM’s amplitude fluctuations cause rapid changing output back-off(OBO)power requirements and further reduce power amplifier(PA)efficiency while CE-FrFTOFDM stable operational linear range makes it a better candidate and outperforms the other techniques when their OBO exceeds 1.7.Higher EE and low BER in time-frequency selective channel are attracting features for CE-FrFT-OFDM deployment in mobile devices.展开更多
An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside di...An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside directly. This kind of structure is named "active pipe-embedded building envelope" due to dealing with the thermal energy actively inside the structure mass by circulating water. This structure not only deals with thermal energy before the external disturbance becomes cooling/heating load by using the circulating water, but also may use low-grade energy sources such as evaporative cooling, solar energy, and geothermal energy. In the meantime, this structure can also improve the indoor thermal comfort by tempering the internal wall surface temperature variation due to the thermal removal in the mass. This work further presents the thermal performance of this structure under a typical hot summer weather condition by comparing it with that of the conventional external wall/roof with numerical simulation. The results show that this pipe-embedded structure may reduce the external heat transfer significantly and reduce the internal wall surface temperature for improving thermal comfort. This work also presents the effects of the water temperature and the pipe spacing on the heat transfer of this structure. The internal surface heat transfer may reduce by about 2.6 W/mE when the water temperature reduces by 1℃ as far as a brick wall with pipes embedded inside is concerned. When the pipe spacing reduces by 50 mm, the internal wall surface heat flux can also reduce by about 2.3 W/m2.展开更多
Passive house has been constructed in China on a large-scale over the past couple years for its great energy saving potential.However,research indicates that there is a significant discrepancy in energy performance fo...Passive house has been constructed in China on a large-scale over the past couple years for its great energy saving potential.However,research indicates that there is a significant discrepancy in energy performance for heating and cooling between passive houses in different climate zones.Therefore,this research develops a comparative analysis on the energy saving potential of passive houses with the conventional around China.A sensitivity analysis of thermal characteristics of building envelope(insulation of exterior walls and windows,and airtightness)on energy consumption is further carried out to improve the climate adaptability of passive house.Moreover,the variation of energy consumption under different heat gain intensity is also compared,to evaluate the effects of envelope thermal characteristics comprehensively.Results suggest that the decrease of exterior wall insulation leads to the greatest increase in energy consumption,especially in severe cold zone in China.However,the optimal insulation may change with the internal heat gain intensity,for instance,the decrease of insulation(from 0.4 to 1.0 W/(m^(2)·K))could reduce the energy consumption by 4.65 kW·h/(m^(2)·a)when the heat gain increases to 20 W/m^(2)for buildings in Hot Summer and Cold Winter zone in China.展开更多
A new facility was presented which can expediently and cheaply measure the transient moisture content profile in multi-layer porous building envelope.Then,a common multi-layer porous building envelope was provided,whi...A new facility was presented which can expediently and cheaply measure the transient moisture content profile in multi-layer porous building envelope.Then,a common multi-layer porous building envelope was provided,which was constructed by cement mortar-red brick-cement plaster.With this kind of building envelope installed in the south wall,a well-controlled air-conditioning room was set up in Changsha,which is one of typical zones of hot and humid climate in China.And experiments were carried out to investigate the temperature and moisture distribution in multi-layer building envelope in summer,both in sunny day and rainy day.The results show that,the temperature and humidity at the interface between the brick and cement mortar are seriously affected by the changes of outdoor temperature and humidity,and the relative humidity at this interface keeps more than 80% for a long-term,which can easily trigger the growth of mould.The temperature and humidity at the interface between the brick and cement plaster change a little,and they are affected by the changes of indoor temperature and humidity.The temperature and humidity at the interface of the wall whose interior surface is affixed with a foam plastic wallpaper are generally higher than those of the wall without wallpaper.The heat transfer and moisture transfer in the envelope are coupled strongly.展开更多
The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studie...The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studied in winter and summer,and compared to envelopes without solar collectors. The results show that the solar collection efficiency is raised in the integration of building envelopes and solar collectors with the air layer doors closed. This is true whether in winter or summer. The increment is higher as the inlet water temperature increases or the ambient temperature is low. In winter,the heat loss is significantly reduced through integration of the building envelopes and solar collectors with the closed air layer doors. The integration with the open air layer door is worse than that without collectors. In summer,the heat gains of the integration of envelopes and solar collectors are more obviously reduced than envelopes without collectors,the integration with the open air layer door is a little better than the closed one,but the difference is very small.展开更多
An envelope domain multislice behavioral modeling is introduced. The tradition AM-AM and AM- PM characteristics of power amplifiers axe extended to envelope domain and base-band filter is applied to distortion complex...An envelope domain multislice behavioral modeling is introduced. The tradition AM-AM and AM- PM characteristics of power amplifiers axe extended to envelope domain and base-band filter is applied to distortion complex envelope signal for description of the envelope memory effect. Using traditional one and two-tone tests, the coefficients of nonlinear model and the FIR filter can be extracted. At last the model has been applied to a 10 W WCDMA Power amplifier to predict its output signal. And simulation results show that the model output conforms very well to the traditional transistor level simulation results.展开更多
规模化农业机械化生产单位在促进土地流转、提高农业机械化水平等方面发挥了巨大作用,农机合作社是规模化生产单位的代表,评价农机合作社总体经营效果对促进农机合作社和其他新型农业生产经营主体的健康发展具有重要意义。以黑龙江省13...规模化农业机械化生产单位在促进土地流转、提高农业机械化水平等方面发挥了巨大作用,农机合作社是规模化生产单位的代表,评价农机合作社总体经营效果对促进农机合作社和其他新型农业生产经营主体的健康发展具有重要意义。以黑龙江省13个地市农机合作社为研究对象,采用Spearman样本正态性(p=0.01)双侧检验方法确定投入和产出评价指标;建立CCR模型(Charnes Cooper Rhodes,CCR)和超效率DEA模型(Super efficiency-DEA)评价黑龙江省13个地市农机合作社的总体效率;引入Malmquist指数评价分析了黑龙江省农机合作社效率动态变化情况。研究结果表明,黑龙江省各地市农机合作社总体效率较高,但不同地市农机合作社超效率和综合效率差异较大,同地市农机合作社不同分析期的总体效率变动也较大;分析期内黑龙江省各地市农机合作社全要素生产率呈先快后缓的增加趋势,平均全要素生产率呈正增长的地市有5个,占比38.46%。研究结果可为农机合作社等新型农业生产经营主体高质量发展提供理论与技术支撑。展开更多
基金supported by the National High Technology Researchand Development Program of China (863 Program) (YJCB2008023WL)
文摘Efficiency and linearity of the microwave power amplifier are critical elements for mobile communication systems. A memory polynomial baseband predistorter based on an indirect learning architecture is presented for improving the linearity of an envelope tracing (ET) amplifier with application to a wireless transmitter. To deal with large peak-to-average ratio (PAR) problem, a clipping procedure for the input signal is employed. Then the system performance is verified by simulation results. For a single carrier wideband code division multiple access (WCDMA) signal of 16-quadrature amplitude modulation (16-QAM), about 2% improvement of the error vector magnitude (EVM) is achieved at an average output power of 45.5 dBm and gain of 10.6 dB, with adjacent channel leakage ratio (ACLR) of -64.55 dBc at offset frequency of 5 MHz. Moreover, a three-carrier WCDMA signal and a third-generation (3G) long term evolution (LTE) signal are used as test signals to demonstrate the performance of the proposed linearization scheme under different bandwidth signals.
文摘Constant envelope with a fractional Fourier transformorthogonal frequency division multiplexing(CE-FrFT-OFDM)is a special case of a constant envelope OFDM(CE-OFDM),both being energy efficient wireless communication techniques with a 0 dB peak to average power ratio(PAPR).However,with the proper selection of fractional order,the first technique has a high bit error rate(BER)performance in the frequency-time selective channels.This paper performs further analysis of CE-FrFT-OFDM by examining its spectral efficiency(SE)and energy efficiency(EE)and compare to the famous OFDM and FrFT-OFDM techniques.Analytical and comprehensive simulations conducted show that,the CE-FrFT-OFDM has five times the EE of OFDM and FrFT-OFDM systems with a slightly less SE.Increasing CE-FrFT-OFDM’s transmission power by increasing its amplitude to 1.7 increases its SE to match that of the OFDM and FrFT-OFDM systems while slightly reducing its EE by 20%to be four times that of OFDM and FrFTOFDM systems.OFDM and FrFT-OFDM’s amplitude fluctuations cause rapid changing output back-off(OBO)power requirements and further reduce power amplifier(PA)efficiency while CE-FrFTOFDM stable operational linear range makes it a better candidate and outperforms the other techniques when their OBO exceeds 1.7.Higher EE and low BER in time-frequency selective channel are attracting features for CE-FrFT-OFDM deployment in mobile devices.
基金Project(51178201) supported by the National Natural Science Foundation of China Project(2011CDB292) supported by the Natural Science Foundation of Hubei Province,China
文摘An active pipe-embedded building envelope, which is an external wall or roof with pipes embedded inside, was presented. This structure may utilize the circulating water in the pipe to transfer heat or coolth inside directly. This kind of structure is named "active pipe-embedded building envelope" due to dealing with the thermal energy actively inside the structure mass by circulating water. This structure not only deals with thermal energy before the external disturbance becomes cooling/heating load by using the circulating water, but also may use low-grade energy sources such as evaporative cooling, solar energy, and geothermal energy. In the meantime, this structure can also improve the indoor thermal comfort by tempering the internal wall surface temperature variation due to the thermal removal in the mass. This work further presents the thermal performance of this structure under a typical hot summer weather condition by comparing it with that of the conventional external wall/roof with numerical simulation. The results show that this pipe-embedded structure may reduce the external heat transfer significantly and reduce the internal wall surface temperature for improving thermal comfort. This work also presents the effects of the water temperature and the pipe spacing on the heat transfer of this structure. The internal surface heat transfer may reduce by about 2.6 W/mE when the water temperature reduces by 1℃ as far as a brick wall with pipes embedded inside is concerned. When the pipe spacing reduces by 50 mm, the internal wall surface heat flux can also reduce by about 2.3 W/m2.
基金Project(51825802)supported by the National Science Foundation for Distinguished Young Scholars of ChinaProject(2018YFE0106100)supported by the National Key R&D Program of China。
文摘Passive house has been constructed in China on a large-scale over the past couple years for its great energy saving potential.However,research indicates that there is a significant discrepancy in energy performance for heating and cooling between passive houses in different climate zones.Therefore,this research develops a comparative analysis on the energy saving potential of passive houses with the conventional around China.A sensitivity analysis of thermal characteristics of building envelope(insulation of exterior walls and windows,and airtightness)on energy consumption is further carried out to improve the climate adaptability of passive house.Moreover,the variation of energy consumption under different heat gain intensity is also compared,to evaluate the effects of envelope thermal characteristics comprehensively.Results suggest that the decrease of exterior wall insulation leads to the greatest increase in energy consumption,especially in severe cold zone in China.However,the optimal insulation may change with the internal heat gain intensity,for instance,the decrease of insulation(from 0.4 to 1.0 W/(m^(2)·K))could reduce the energy consumption by 4.65 kW·h/(m^(2)·a)when the heat gain increases to 20 W/m^(2)for buildings in Hot Summer and Cold Winter zone in China.
基金Project(51078127) supported by the National Natural Science Foundation of China
文摘A new facility was presented which can expediently and cheaply measure the transient moisture content profile in multi-layer porous building envelope.Then,a common multi-layer porous building envelope was provided,which was constructed by cement mortar-red brick-cement plaster.With this kind of building envelope installed in the south wall,a well-controlled air-conditioning room was set up in Changsha,which is one of typical zones of hot and humid climate in China.And experiments were carried out to investigate the temperature and moisture distribution in multi-layer building envelope in summer,both in sunny day and rainy day.The results show that,the temperature and humidity at the interface between the brick and cement mortar are seriously affected by the changes of outdoor temperature and humidity,and the relative humidity at this interface keeps more than 80% for a long-term,which can easily trigger the growth of mould.The temperature and humidity at the interface between the brick and cement plaster change a little,and they are affected by the changes of indoor temperature and humidity.The temperature and humidity at the interface of the wall whose interior surface is affixed with a foam plastic wallpaper are generally higher than those of the wall without wallpaper.The heat transfer and moisture transfer in the envelope are coupled strongly.
基金Project(2006BAJ01A12-10-03) supported by the National Natural Science Foundation of ChinaProject(J50502) supported by the Leading Discipline of Shanghai Education Commission,China
文摘The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studied in winter and summer,and compared to envelopes without solar collectors. The results show that the solar collection efficiency is raised in the integration of building envelopes and solar collectors with the air layer doors closed. This is true whether in winter or summer. The increment is higher as the inlet water temperature increases or the ambient temperature is low. In winter,the heat loss is significantly reduced through integration of the building envelopes and solar collectors with the closed air layer doors. The integration with the open air layer door is worse than that without collectors. In summer,the heat gains of the integration of envelopes and solar collectors are more obviously reduced than envelopes without collectors,the integration with the open air layer door is a little better than the closed one,but the difference is very small.
文摘An envelope domain multislice behavioral modeling is introduced. The tradition AM-AM and AM- PM characteristics of power amplifiers axe extended to envelope domain and base-band filter is applied to distortion complex envelope signal for description of the envelope memory effect. Using traditional one and two-tone tests, the coefficients of nonlinear model and the FIR filter can be extracted. At last the model has been applied to a 10 W WCDMA Power amplifier to predict its output signal. And simulation results show that the model output conforms very well to the traditional transistor level simulation results.
文摘规模化农业机械化生产单位在促进土地流转、提高农业机械化水平等方面发挥了巨大作用,农机合作社是规模化生产单位的代表,评价农机合作社总体经营效果对促进农机合作社和其他新型农业生产经营主体的健康发展具有重要意义。以黑龙江省13个地市农机合作社为研究对象,采用Spearman样本正态性(p=0.01)双侧检验方法确定投入和产出评价指标;建立CCR模型(Charnes Cooper Rhodes,CCR)和超效率DEA模型(Super efficiency-DEA)评价黑龙江省13个地市农机合作社的总体效率;引入Malmquist指数评价分析了黑龙江省农机合作社效率动态变化情况。研究结果表明,黑龙江省各地市农机合作社总体效率较高,但不同地市农机合作社超效率和综合效率差异较大,同地市农机合作社不同分析期的总体效率变动也较大;分析期内黑龙江省各地市农机合作社全要素生产率呈先快后缓的增加趋势,平均全要素生产率呈正增长的地市有5个,占比38.46%。研究结果可为农机合作社等新型农业生产经营主体高质量发展提供理论与技术支撑。