A homological multi-information image fusion method was introduced for recognition of the gastric tumor pathological tissue images.The main purpose is that fewer procedures are used to provide more information and the...A homological multi-information image fusion method was introduced for recognition of the gastric tumor pathological tissue images.The main purpose is that fewer procedures are used to provide more information and the result images could be easier to be understood than any other methods.First,multi-scale wavelet transform was used to extract edge feature,and then watershed morphology was used to form multi-threshold grayscale contours.The research laid emphasis upon the homological tissue image fusion based on extended Bayesian algorithm,which fusion result images of linear weighted algorithm was used to compare with the ones of extended Bayesian algorithm.The final fusion images are shown in Fig 5.The final image evaluation was made by information entropy,information correlativity and statistics methods.It is indicated that this method has more advantages for clinical application.展开更多
We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacu...We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacuum environment and produce a GaN photocathode with a negative electron affinity (NEA) status. Information including the heat clean- ing temperature, vacuum degree, photocurrent, electric current of cesium source, oxygen source, and the most important information about the spectral response, or equivalently, the quantum efficiency (QE) can be obtained during prepa- ration. The preparation of a GaN photocathode with this system indicates that the optimal heating temperature in a vacuum is about 700 ~C. We also develop a method of quickly evaluating the atomically clean surface with the vacuum degree versus wavelength curve to prevent possible secondary contamination when the atomic level cleaning surface is tested with X-ray photoelectron spectroscopy. The photocurrent shows a quick enhancement when the current ratio between the cesium source and oxygen source is 1.025. The spectral response of the GaN photocathode is flat in a wavelength range from 240 nm to 365 nm, and an abrupt decline is observed at 365 nm, which demonstrates that with the in-si$u multi-information measurement system the NEA GaN photocathode can be successfully prepared.展开更多
基金Supported by the National Science Foundation of China(No.30370403 )
文摘A homological multi-information image fusion method was introduced for recognition of the gastric tumor pathological tissue images.The main purpose is that fewer procedures are used to provide more information and the result images could be easier to be understood than any other methods.First,multi-scale wavelet transform was used to extract edge feature,and then watershed morphology was used to form multi-threshold grayscale contours.The research laid emphasis upon the homological tissue image fusion based on extended Bayesian algorithm,which fusion result images of linear weighted algorithm was used to compare with the ones of extended Bayesian algorithm.The final fusion images are shown in Fig 5.The final image evaluation was made by information entropy,information correlativity and statistics methods.It is indicated that this method has more advantages for clinical application.
基金Project supported by the National Natural Science Foundation of China (Grant No. 60871012)the Natural Science Foundation of Shandong Province,China (Grant No. ZR2011FQ027)
文摘We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacuum environment and produce a GaN photocathode with a negative electron affinity (NEA) status. Information including the heat clean- ing temperature, vacuum degree, photocurrent, electric current of cesium source, oxygen source, and the most important information about the spectral response, or equivalently, the quantum efficiency (QE) can be obtained during prepa- ration. The preparation of a GaN photocathode with this system indicates that the optimal heating temperature in a vacuum is about 700 ~C. We also develop a method of quickly evaluating the atomically clean surface with the vacuum degree versus wavelength curve to prevent possible secondary contamination when the atomic level cleaning surface is tested with X-ray photoelectron spectroscopy. The photocurrent shows a quick enhancement when the current ratio between the cesium source and oxygen source is 1.025. The spectral response of the GaN photocathode is flat in a wavelength range from 240 nm to 365 nm, and an abrupt decline is observed at 365 nm, which demonstrates that with the in-si$u multi-information measurement system the NEA GaN photocathode can be successfully prepared.