期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Shim coil design for Halbach magnet by equivalent magnetic dipole method 被引量:1
1
作者 Jia-Min Wu Zheng Xu +2 位作者 Pan Guo Jin-Feng Qi Yu-Cheng He 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第10期300-307,共8页
Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Theref... Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils. 展开更多
关键词 equivalent magnetic dipole method shim coils magnetic resonance Halbach magnet
在线阅读 下载PDF
Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging
2
作者 Zheng Xu Xiang Lil +1 位作者 Pan Guo Jia-Min Wu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期545-550,共6页
The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this ... The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this study focuses on the design of gradient coil of unilateral magnet.The unilateral MRI system is used to image the local area above the magnet.The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils,because the region of interest(ROI)and the wiring area of the unilateral magnet are both cylindrical side arc surfaces.Therefore,the equivalent magnetic dipole method is used to design the gradient coil,and the algorithm is improved for the special case of the wiring area and the ROI,so the X and Y gradient coils are designed.Finally,a flexible printed circuit board(PCB)is used to fabricate the gradient coil,and the magnetic field distribution of the ROI is measured by a Gauss meter,and the measured results match with the simulation results.The gradient linearities of x and y coils are 2.82%and 3.56%,respectively,less than 5%of the commercial gradient coil requirement. 展开更多
关键词 unilateral MRI equivalent magnetic dipole method gradient coil current density distribution
在线阅读 下载PDF
Calculating magnetic shielding effectiveness for high-power dc comparator by magnetic circuit method
3
作者 WANG Xiao-wei REN Shi-yan 《Journal of Chongqing University》 CAS 2007年第2期113-118,共6页
Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comp... Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comparators when an external radial magnetic field is added. The mathematical relationship between the magnetic shielding effectiveness and the parameters of the magnetic shielding body were obtained. To verify the validity of the calculation method, we developped a procedure to measure the magnetic shielding effectiveness of the magnetic body by measuring the induction voltage of the detection winding instead of the magnetic intensity at a point in the magnetic shielding body, making the manipulation much easier. The result calculated with the magnetic circuit method turns out to be closer to the measured one compared with that calculated with a conventional algorithm proposed by Ren, suggesting that the magnetic circuit method is an applicable tool for estimating the toroidal cavity magnetic shielding effectiveness of a heavy current comparator when a radial magnetic field is added. 展开更多
关键词 radial magnetic field magnetic shielding effectiveness magnetic circuit analysis method magnetic potential
在线阅读 下载PDF
Numerical and experimental studies on the effectiveness of time-varying electromagnetic fields in reducing electron density
4
作者 郭韶帅 谢楷 +2 位作者 徐晗 付麦霞 牛营营 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期30-40,共11页
When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on tim... When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on time-varying E×B fields is proposed to improve on the existing static E×B fields and mitigate the radio blackout problem.The use of the existing method is limited by the invalid electron density reduction resulting from current density j=0 A m^(-2)in plasma beyond the Debye radius.The most remarkable feature is the introduction of a time-varying electric field to increase the current density in the plasma to overcome the Debye shielding effect on static electric field.Meanwhile,a magnetic field with the same frequency and phase as the electric field is applied to ensure that the electromagnetic force is always acting on the plasma in one direction.In order to investigate the effect of time-varying E×B fields on the plasma electron density distribution,two directions of voltage application are considered in numerical simulation.The simulation results indicate that different voltage application methods generate electromagnetic forces in different directions in the plasma,resulting in repulsion and vortex effects in the plasma.A comparison of the vortex effect and repulsion effect reveals that the vortex effect is better at reducing the electron density.The local plasma electron density can be reduced by more than 80%through the vortex effect,and the dimensions of the area of reduced electron density reach approximately 6 cm×4 cm,meeting the requirements of electromagnetic wave propagation.Besides,the vortex effect of reducing the electron density in RAM-C(radio attenuation measurements for the study of communication blackout)reentry at an altitude of 40 km is analyzed.On the basis of the simulation results,an experiment based on a rectangular-window discharge device is proposed to demonstrate the effectiveness of the vortex effect.Experimental results show that time-varying E×B fields can reduce the electron density in plasma of 3 cm thickness by 80%at B=0.07 T and U_(0)=1000 V.The investigations confirm the effectiveness of the proposed method in terms of reducing the required strength of the magnetic field and overcoming the Debye shielding effect.Additionally,the method is expected to provide a new way to apply a magnetic window in engineering applications. 展开更多
关键词 BLACKOUT magnetic window method time-varying E×B fields
在线阅读 下载PDF
Magnetic transition of ferromagnetic material at high pressure using a novel system
5
作者 胡天立 王鑫 +4 位作者 韩冰 李岩 黄凤仙 周强 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期173-176,共4页
A system for the investigation of the magnetic properties of materials under high pressure is fabricated based on diamond anvil cell (DAC) technology. The system is designed with an improved coil arranged around the... A system for the investigation of the magnetic properties of materials under high pressure is fabricated based on diamond anvil cell (DAC) technology. The system is designed with an improved coil arranged around the diamond of a non-magnetic DAC. Using this system, the magnetic transition of ferromagnetic (Fe) sample under increasing pressure can be observed. We successfully obtain the evolution of magnetic properties as a function of applied pressure reaching 26.9 GPa in the Fe sample. A magnetic transition is observed at approximately 13 GPa, which is consistent with the theoretical prediction. 展开更多
关键词 diamond anvil cell magnetic transition mutual inductance method transition pressure
在线阅读 下载PDF
上一页 1 下一页 到第