Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Theref...Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.展开更多
The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this ...The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this study focuses on the design of gradient coil of unilateral magnet.The unilateral MRI system is used to image the local area above the magnet.The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils,because the region of interest(ROI)and the wiring area of the unilateral magnet are both cylindrical side arc surfaces.Therefore,the equivalent magnetic dipole method is used to design the gradient coil,and the algorithm is improved for the special case of the wiring area and the ROI,so the X and Y gradient coils are designed.Finally,a flexible printed circuit board(PCB)is used to fabricate the gradient coil,and the magnetic field distribution of the ROI is measured by a Gauss meter,and the measured results match with the simulation results.The gradient linearities of x and y coils are 2.82%and 3.56%,respectively,less than 5%of the commercial gradient coil requirement.展开更多
Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comp...Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comparators when an external radial magnetic field is added. The mathematical relationship between the magnetic shielding effectiveness and the parameters of the magnetic shielding body were obtained. To verify the validity of the calculation method, we developped a procedure to measure the magnetic shielding effectiveness of the magnetic body by measuring the induction voltage of the detection winding instead of the magnetic intensity at a point in the magnetic shielding body, making the manipulation much easier. The result calculated with the magnetic circuit method turns out to be closer to the measured one compared with that calculated with a conventional algorithm proposed by Ren, suggesting that the magnetic circuit method is an applicable tool for estimating the toroidal cavity magnetic shielding effectiveness of a heavy current comparator when a radial magnetic field is added.展开更多
When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on tim...When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on time-varying E×B fields is proposed to improve on the existing static E×B fields and mitigate the radio blackout problem.The use of the existing method is limited by the invalid electron density reduction resulting from current density j=0 A m^(-2)in plasma beyond the Debye radius.The most remarkable feature is the introduction of a time-varying electric field to increase the current density in the plasma to overcome the Debye shielding effect on static electric field.Meanwhile,a magnetic field with the same frequency and phase as the electric field is applied to ensure that the electromagnetic force is always acting on the plasma in one direction.In order to investigate the effect of time-varying E×B fields on the plasma electron density distribution,two directions of voltage application are considered in numerical simulation.The simulation results indicate that different voltage application methods generate electromagnetic forces in different directions in the plasma,resulting in repulsion and vortex effects in the plasma.A comparison of the vortex effect and repulsion effect reveals that the vortex effect is better at reducing the electron density.The local plasma electron density can be reduced by more than 80%through the vortex effect,and the dimensions of the area of reduced electron density reach approximately 6 cm×4 cm,meeting the requirements of electromagnetic wave propagation.Besides,the vortex effect of reducing the electron density in RAM-C(radio attenuation measurements for the study of communication blackout)reentry at an altitude of 40 km is analyzed.On the basis of the simulation results,an experiment based on a rectangular-window discharge device is proposed to demonstrate the effectiveness of the vortex effect.Experimental results show that time-varying E×B fields can reduce the electron density in plasma of 3 cm thickness by 80%at B=0.07 T and U_(0)=1000 V.The investigations confirm the effectiveness of the proposed method in terms of reducing the required strength of the magnetic field and overcoming the Debye shielding effect.Additionally,the method is expected to provide a new way to apply a magnetic window in engineering applications.展开更多
A system for the investigation of the magnetic properties of materials under high pressure is fabricated based on diamond anvil cell (DAC) technology. The system is designed with an improved coil arranged around the...A system for the investigation of the magnetic properties of materials under high pressure is fabricated based on diamond anvil cell (DAC) technology. The system is designed with an improved coil arranged around the diamond of a non-magnetic DAC. Using this system, the magnetic transition of ferromagnetic (Fe) sample under increasing pressure can be observed. We successfully obtain the evolution of magnetic properties as a function of applied pressure reaching 26.9 GPa in the Fe sample. A magnetic transition is observed at approximately 13 GPa, which is consistent with the theoretical prediction.展开更多
基金Project supported by the State Key Development Program for Basic Research of China(Grant No.2014CB541602)the National Natural Science Foundation of China(Grant Nos.51677008 and 51707028)the Fundamental Research Funds of Central Universities,China(Grant No.106112015CDJXY150003)
文摘Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51677008,51377182,51707028,and 11647098)the Fundamental Research Funds of the Central Universities,China(Grant No.106112017CDJQJ158834)the State Key Development Program for Basic Research of China(Grant No.2014CB541602)
文摘The conventional magnetic resonance imaging(MRI)equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure.In order to realize the mobile MRI,this study focuses on the design of gradient coil of unilateral magnet.The unilateral MRI system is used to image the local area above the magnet.The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils,because the region of interest(ROI)and the wiring area of the unilateral magnet are both cylindrical side arc surfaces.Therefore,the equivalent magnetic dipole method is used to design the gradient coil,and the algorithm is improved for the special case of the wiring area and the ROI,so the X and Y gradient coils are designed.Finally,a flexible printed circuit board(PCB)is used to fabricate the gradient coil,and the magnetic field distribution of the ROI is measured by a Gauss meter,and the measured results match with the simulation results.The gradient linearities of x and y coils are 2.82%and 3.56%,respectively,less than 5%of the commercial gradient coil requirement.
基金Funded by the Natural Science Foundation of China under the grant number 50277018.
文摘Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comparators when an external radial magnetic field is added. The mathematical relationship between the magnetic shielding effectiveness and the parameters of the magnetic shielding body were obtained. To verify the validity of the calculation method, we developped a procedure to measure the magnetic shielding effectiveness of the magnetic body by measuring the induction voltage of the detection winding instead of the magnetic intensity at a point in the magnetic shielding body, making the manipulation much easier. The result calculated with the magnetic circuit method turns out to be closer to the measured one compared with that calculated with a conventional algorithm proposed by Ren, suggesting that the magnetic circuit method is an applicable tool for estimating the toroidal cavity magnetic shielding effectiveness of a heavy current comparator when a radial magnetic field is added.
基金supported by the Research Foundation for Advanced Talents of Henan University of Technology(No.31401482)National Natural Science Foundation of China(No.52107162)+2 种基金the Research Foundation for University Key Teacher of Henan Province(No.2020GGJS084)the Research Foundation for Key Teacher of Henan University of Technologythe Foundation of Henan Science and Technology Agency(No.222102210186)。
文摘When an aircraft or a hypersonic vehicle re-enters the atmosphere,the plasma sheath generated can severely attenuate electromagnetic wave signals,causing the problem of communication blackout.A new method based on time-varying E×B fields is proposed to improve on the existing static E×B fields and mitigate the radio blackout problem.The use of the existing method is limited by the invalid electron density reduction resulting from current density j=0 A m^(-2)in plasma beyond the Debye radius.The most remarkable feature is the introduction of a time-varying electric field to increase the current density in the plasma to overcome the Debye shielding effect on static electric field.Meanwhile,a magnetic field with the same frequency and phase as the electric field is applied to ensure that the electromagnetic force is always acting on the plasma in one direction.In order to investigate the effect of time-varying E×B fields on the plasma electron density distribution,two directions of voltage application are considered in numerical simulation.The simulation results indicate that different voltage application methods generate electromagnetic forces in different directions in the plasma,resulting in repulsion and vortex effects in the plasma.A comparison of the vortex effect and repulsion effect reveals that the vortex effect is better at reducing the electron density.The local plasma electron density can be reduced by more than 80%through the vortex effect,and the dimensions of the area of reduced electron density reach approximately 6 cm×4 cm,meeting the requirements of electromagnetic wave propagation.Besides,the vortex effect of reducing the electron density in RAM-C(radio attenuation measurements for the study of communication blackout)reentry at an altitude of 40 km is analyzed.On the basis of the simulation results,an experiment based on a rectangular-window discharge device is proposed to demonstrate the effectiveness of the vortex effect.Experimental results show that time-varying E×B fields can reduce the electron density in plasma of 3 cm thickness by 80%at B=0.07 T and U_(0)=1000 V.The investigations confirm the effectiveness of the proposed method in terms of reducing the required strength of the magnetic field and overcoming the Debye shielding effect.Additionally,the method is expected to provide a new way to apply a magnetic window in engineering applications.
基金Project supported by the Open Project of State Key Laboratory of Superhard Materials(Jilin University),China(Grant No.201106)
文摘A system for the investigation of the magnetic properties of materials under high pressure is fabricated based on diamond anvil cell (DAC) technology. The system is designed with an improved coil arranged around the diamond of a non-magnetic DAC. Using this system, the magnetic transition of ferromagnetic (Fe) sample under increasing pressure can be observed. We successfully obtain the evolution of magnetic properties as a function of applied pressure reaching 26.9 GPa in the Fe sample. A magnetic transition is observed at approximately 13 GPa, which is consistent with the theoretical prediction.