The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tande...The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines.展开更多
Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, s...Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, some compounds do not show enough sensitivity in LC/MS and soft ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), sometimes do not give satisfactory structural information This report presents an overview of the derivatization methods in the LC/MS analysis of neurosteroids or neuroactive neurosteroids, which are synthesized and accumulated in the nervous system The derivatization of pregnenolone 3 sulfate, one of these steroids, with 4 ( N,N dimethylaminosulfonyl) 7 hydrazino 2,1,3 benzoxadiazole gave a satisfactory sensitivity during the quantitative analysis using LC/ESI MS The obtained results are much lower than those previously obtained using gas chromatography/mass spectrometry or radioimmunoassay On the other hand, the derivatization to acetate was useful for the treatment of labile catechol estrogens in rat brains and gave enough structural information in LC/APCI MS, which confirmed the existence of catechol estrogens in mammalian展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
建立了污水中26种痕量卡西酮类新精神活性物质的前处理及同时定量检测的方法,并成功应用于实际污水样品的检测。污水样品经过滤和加入内标溶液的预处理,在Oasis PRiME HLB固相萃取柱上经超纯水淋洗和甲醇溶液洗脱,在40℃下氮气吹干,用0...建立了污水中26种痕量卡西酮类新精神活性物质的前处理及同时定量检测的方法,并成功应用于实际污水样品的检测。污水样品经过滤和加入内标溶液的预处理,在Oasis PRiME HLB固相萃取柱上经超纯水淋洗和甲醇溶液洗脱,在40℃下氮气吹干,用0.1%甲酸-乙腈溶液(95∶5)复溶,利用高效液相色谱-串联质谱(high-performance liquid chromatography-tandem mass spectrometry,HPLC-MS/MS)技术,采用选择反应监测(selected reaction monitoring,SRM)模式,用UPLC BEH C_(18)(100 mm×2.1 mm,1.7μm)色谱柱,柱温35℃,流动相为乙腈-0.1%甲酸的水溶液,梯度洗脱进行检测。经方法学验证,26种卡西酮类新精神活性物质的定量下限可达1.50~3.00 ng/L,其中21种待测物在1.50~375.0 ng/L范围内,5种在3.00~750.0 ng/L范围内,所有26种物质均具有良好的线性关系,相关系数r为0.99,批内和批间精密度的相对标准偏差(relative standard deviation,RSD)分别小于7.71%和13.91%,提取回收率均高于92.64%。该方法简单、准确、灵敏,可作为卡西酮类物质检测和滥用情况监测的方法。展开更多
文摘The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines.
文摘Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, some compounds do not show enough sensitivity in LC/MS and soft ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), sometimes do not give satisfactory structural information This report presents an overview of the derivatization methods in the LC/MS analysis of neurosteroids or neuroactive neurosteroids, which are synthesized and accumulated in the nervous system The derivatization of pregnenolone 3 sulfate, one of these steroids, with 4 ( N,N dimethylaminosulfonyl) 7 hydrazino 2,1,3 benzoxadiazole gave a satisfactory sensitivity during the quantitative analysis using LC/ESI MS The obtained results are much lower than those previously obtained using gas chromatography/mass spectrometry or radioimmunoassay On the other hand, the derivatization to acetate was useful for the treatment of labile catechol estrogens in rat brains and gave enough structural information in LC/APCI MS, which confirmed the existence of catechol estrogens in mammalian
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.