期刊文献+
共找到8,120篇文章
< 1 2 250 >
每页显示 20 50 100
Implementation of a double trigger condition system based on charge comparison and TOF measurement for the NEDA detector array
1
作者 J.M.Deltoro A.Goasduff +19 位作者 F.J.Egea V.González A.Gadea R.M.Pérez-Vidal I.Lazarus M.Kogimtzis L.McNicholl M.Palacz G.Jaworski J.J.Valiente-Dobón J.Nyberg S.Casans A.E.Navarro-Antón E.Sanchis A.Boujrad E.Clément T.Hüyük R.Illicachi O.Stezowski V.Modamio 《Nuclear Science and Techniques》 2025年第2期40-48,共9页
The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This arti... The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This article presents the implementation of a double trigger condition system for NEDA,which improves the acquisition of neutrons and reduces the number of gamma rays acquired.Two independent triggers are generated in the double trigger condition system:one based on charge comparison(CC)and the other on time-of-flight(TOF).These triggers can be combined using OR and AND logic,offering four distinct trigger modes.The developed firmware is added to the previous one in the Virtex 6 field programmable gate array(FPGA)present in the system,which also includes signal processing,baseline correction,and various trigger logic blocks.The performance of the trigger system is evaluated using data from the E703 experiment performed at GANIL.The four trigger modes are applied to the same data,and a subsequent offline analysis is performed.It is shown that most of the detected neutrons are preserved with the AND mode,and the total number of gamma rays is significantly reduced.Compared with the CC trigger mode,the OR trigger mode allows increasing the selection of neutrons.In addition,it is demonstrated that if the OR mode is selected,the online CC trigger threshold can be raised without losing neutrons. 展开更多
关键词 Neutron detector Neutron-gamma discrimination Pulse shape analysis TIME-OF-FLIGHT Charge comparison
在线阅读 下载PDF
CMOS direct conversion X-ray detector coupled with fluorinated liquid
2
作者 Shi-Hua Liu Chao-Song Gao +5 位作者 Xin Zhang Xiang-Ming Sun Meng Wu Zhi-Hui Han Tong Wan Yong-Shuai Ge 《Nuclear Science and Techniques》 2025年第1期59-68,共10页
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho... X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors. 展开更多
关键词 FC40 electronic fluorinated liquid CMOS pixel chip X-ray detector Spatial resolution
在线阅读 下载PDF
Readout electronics for the gamma detector of the HIRFL-CSR external target facility
3
作者 Xian-Qin Li Hai-Bo Yang +10 位作者 Xiao-Meng Ma Chao-Jie Zou Tao Liu Xian-Cai Zhou Duo Yan Yang-Zhou Su Shu-Wen Tang Shi-Tao Wang Yu-Hong Yu Zhi-Yu Sun Cheng-Xin Zhao 《Nuclear Science and Techniques》 2025年第2期71-81,共11页
The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(... The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics. 展开更多
关键词 HIRFL-CSR Gamma detector External target facility Readout electronics Readout control unit Common readout unit Peak-detection algorithm
在线阅读 下载PDF
Reconstruction of pile-up events using a one-dimensional convolutional autoencoder for the NEDA detector array
4
作者 J.M.Deltoro G.Jaworski +15 位作者 A.Goasduff V.González A.Gadea M.Palacz J.J.Valiente-Dobón J.Nyberg S.Casans A.E.Navarro-Antón E.Sanchis G.de Angelis A.Boujrad S.Coudert T.Dupasquier S.Ertürk O.Stezowski R.Wadsworth 《Nuclear Science and Techniques》 2025年第2期62-70,共9页
Pulse pile-up is a problem in nuclear spectroscopy and nuclear reaction studies that occurs when two pulses overlap and distort each other,degrading the quality of energy and timing information.Different methods have ... Pulse pile-up is a problem in nuclear spectroscopy and nuclear reaction studies that occurs when two pulses overlap and distort each other,degrading the quality of energy and timing information.Different methods have been used for pile-up rejection,both digital and analogue,but some pile-up events may contain pulses of interest and need to be reconstructed.The paper proposes a new method for reconstructing pile-up events acquired with a neutron detector array(NEDA)using an one-dimensional convolutional autoencoder(1D-CAE).The datasets for training and testing the 1D-CAE are created from data acquired from the NEDA.The new pile-up signal reconstruction method is evaluated from the point of view of how similar the reconstructed signals are to the original ones.Furthermore,it is analysed considering the result of the neutron-gamma discrimination based on charge comparison,comparing the result obtained from original and reconstructed signals. 展开更多
关键词 1D-CAE Autoencoder CAE Convolutional neural network(CNN) Neutron detector Neutron-gamma discrimination(NGD) Machine learning Pulse shape discrimination Pile-up pulse
在线阅读 下载PDF
Metal-Halide Perovskite Submicrometer-Thick Films for Ultra-Stable Self-Powered Direct X-Ray Detectors 被引量:1
5
作者 Marco Girolami Fabio Matteocci +7 位作者 Sara Pettinato Valerio Serpente Eleonora Bolli Barbara Paci Amanda Generosi Stefano Salvatori Aldo Di Carlo Daniele M.Trucchi 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第9期410-431,共22页
Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a... Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced. 展开更多
关键词 Metal-halide perovskite thin films Direct X-ray detectors Self-powered devices Operational stability Medical linear accelerator
在线阅读 下载PDF
Low-noise and low-power pixel sensor chip for gas pixel detectors
6
作者 Zhuo Zhou Shi-Qiang Zhou +8 位作者 Dong Wang Xiang-Ming Sun Chao-Song Gao Peng-Zhen Zhu Wei-Ping Ren Jun Liu Mu-Xian Li Chen Lian Chun-Lai Dong 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期142-152,共11页
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm... Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests. 展开更多
关键词 Charge collection Gas detectors Semiconductor detectors X-ray detectors
在线阅读 下载PDF
Flexibility potential of Cs_(2)BX_(6)(B=Hf,Sn,Pt,Zr,Ti;X=I,Br,Cl)with application in photovoltaic devices and radiation detectors
7
作者 Songya Wang Changcheng Chen +11 位作者 Shaohang Shi Ziyi Zhang Yan Cai Shuli Gao Wen Chen Shuangna Guo Elyas Abduryim Chao Dong Xiaoning Guan Ying Liu Gang Liu Pengfei Lu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第8期271-287,I0006,共18页
As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and... As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and optical properties,research on mechanical aspects is limited.This article builds a vacancyordered double perovskite model,employing first-principles calculations to analyze mechanical,bonding,electronic,and optical properties.Results show Cs_(2)Hfl_(6),Cs_(2)SnBr_(6),Cs_(2)SnI_(6),and Cs_(2)PtBr_(6)have Young's moduli below 13 GPa,indicating flexibility.Geometric parameters explain flexibility variations with the changes of B and X site composition.Bonding characteristic exploration reveals the influence of B and X site electronegativity on mechanical strength.Cs_(2)SnBr_(6)and Cs_(2)PtBr_(6)are suitable for solar cells,while Cs_(2)HfI_(6)and Cs_(2)TiCl_(6)show potential for semi-transparent solar cells.Optical property calculations highlight the high light absorption coefficients of up to 3.5×10^(5) cm^(-1)for Cs_(2)HfI_(6)and Cs_(2)TiCl_(6).Solar cell simulation shows Cs_(2)PtBr_(6)achieves 22.4%of conversion effciency.Cs_(2)ZrCl_(6)holds promise for ionizing radiation detection with its 3.68 eV bandgap and high absorption coefficient.Vacancy-ordered double perovskites offer superior flexibility,providing valuable insights for designing stable and flexible devices.This understanding enhances the development of functional devices based on these perovskites,especially for applications requiring high stability and flexibility. 展开更多
关键词 Double perovskite Mechanical properties Flexible PHOTOVOLTAIC Radiation detectors
在线阅读 下载PDF
Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector
8
作者 Dong Zhao Xu-Wen Liang +6 位作者 Ping-Kun Cai Wei Cheng Wen-Bao Jia Da-Qian Hei Qing Shan Yong-Sheng Ling Chao Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期1-14,共14页
Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and ne... Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and neutron source hotspot imaging based on a depth-of-interaction(DOI)detector.The imager primarily consists of a DOI detector system and a rotary dual-layer cylindrical coded mask.An EJ276 plastic scintillator coupled with two SiPMs was designed as the DOI detector to increase the field of view and improve the imager performance.The difference in signal time at both ends and the log of the signal amplitude ratio were used to calculate the interaction position resolution.The position resolution of the DOI detector was calibrated using a collimated Cs-137 source,and the full width at half maximum of the reconstruction position of the Gaussian fitting curve was approximately 4.4 cm.The DOI detector can be arbitrarily divided into several units to independently reconstruct the source distribution images.The unit length was optimized via Am-Be source-location experiments.A multidetector filtering method is proposed for image denoising.This method can effectively reduce image noise caused by poor DOI detector position resolution.The vertical field of view of the imager was(-55°,55°)when the detector was placed in the center of the coded mask.A DT neutron source at 20 m standoff could be located within 2400 s with an angular resolution of 3.5°. 展开更多
关键词 Time-encoded imager Depth-of-interaction detector Dual-particle imaging Hotspot imaging
在线阅读 下载PDF
Method for detector description conversion from DD4hep to Filmbox
9
作者 Zhao-Yang Yuan Tian-Zi Song +3 位作者 Yu-Jie Zeng Kai-Xuan Huang Yu-Mei Zhang Zheng-Yun You 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期115-126,共12页
DD4hep serves as a generic detector description toolkit recommended for offline software development in next-generation high-energy physics(HEP)experiments.Conversely,Filmbox(FBX)stands out as a widely used 3D modelin... DD4hep serves as a generic detector description toolkit recommended for offline software development in next-generation high-energy physics(HEP)experiments.Conversely,Filmbox(FBX)stands out as a widely used 3D modeling file format within the 3D software industry.In this paper,we introduce a novel method that can automatically convert complex HEP detector geometries from DD4hep description into 3D models in the FBX format.The feasibility of this method was dem-onstrated by its application to the DD4hep description of the Compact Linear Collider detector and several sub-detectors of the super Tau-Charm facility and circular electron-positron collider experiments.The automatic DD4hep–FBX detector conversion interface provides convenience for further development of applications,such as detector design,simulation,visualization,data monitoring,and outreach,in HEP experiments. 展开更多
关键词 detector description DD4hep FBX GEOMETRY Offline software
在线阅读 下载PDF
FPGA implementation of 500-MHz high-count-rate high-time-resolution real-time digital neutron-gamma discrimination for fast liquid detectors
10
作者 Hui‑Yin Shen Jing‑Long Zhang +1 位作者 Jie Zhang Jian‑Hang Zhou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期101-113,共13页
Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a sel... Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV. 展开更多
关键词 Neutron-gamma discrimination Liquid scintillation detector Real-time spectrum analyzer
在线阅读 下载PDF
Gas microchannel plate-pixel detector for X-ray polarimetry
11
作者 Huan-Bo Feng Hong-Bang Liu +16 位作者 Dong Wang Zi-Li Li Shu-Lin Liu Qian Liu Hang-Zhou Li Bin-Long Wang Yan-Jun Xie Zong-Wang Fan Hui Wang Ran Chen Di-Fan Yi Rui-Ting Ma Fei Xie Bo Peng Xiang-Ming Sun Jin Li En-Wei Liang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期60-73,共14页
POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polar... POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area. 展开更多
关键词 X-ray polarimetry Gas microchannel plate-pixel detector Gamma-ray bursts
在线阅读 下载PDF
Construction and performance test of charged particle detector array for MATE
12
作者 Xiao‑Bin Li Long‑Hui Ru +14 位作者 Zhi‑Chao Zhang Bing‑Feng Lv Ning‑Tao Zhang Jin‑Long Zhang Chen‑Gui Lu Bing‑Shui Gao Jun‑Bing Ma Fu‑Shuai Shi Satoru Terashima Xiao‑Dong Xu Zhen Bai Shi‑Wei Xu Yan‑Yun Yang Hooi‑Jin Ong Xiao‑Dong Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期92-100,共9页
A charged particle array named MATE-PA,which serves as an auxiliary detector system for a Multi-purpose Active-target Time projection chamber used in nuclear astrophysical and exotic beam Experiments(MATE),was constru... A charged particle array named MATE-PA,which serves as an auxiliary detector system for a Multi-purpose Active-target Time projection chamber used in nuclear astrophysical and exotic beam Experiments(MATE),was constructed.The array comprised of 20 single-sided strip-silicon detectors covering approximately 10%of the solid angle.The detectors facilitated the detection of reaction-induced charged particles that penetrate the active volume of the MATE.The performance of MATE-PA has been experimentally studied using an alpha source and a 36-MeV 14 N beam injected into the MATE chamber on the radioactive ion beam line in Lanzhou(RIBLL).The chamber was filled with a gas mixture of 95%4 He and 5%CO_(2) at a pressure of 500 mbar.The results indicated good separation of light-charged particles using the forward double-layer silicon detectors of MATE-PA.The energy resolution of the Si detectors was deduced to be approximately 1%(σ)for an energy loss of approximately 10 MeV caused by theαparticles.The inclusion of MATE-PA improves particle identification and increases the dynamic range of the kinetic energy of charged particles,particularly that of theαparticles,up to approximately 15 MeV. 展开更多
关键词 Silicon detector array Active target Time projection chamber
在线阅读 下载PDF
Structural design of mid-infrared waveguide detectors based on InAs/GaAsSb superlattice
13
作者 PEI Jin-Di CHAI Xu-Liang +1 位作者 WANG Yu-Peng ZHOU Yi 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第4期457-463,共7页
In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are of... In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are often constrained by the reliance on off-chip light sources and detectors.In this study,we demonstrate an InAs/GaAsSb superlattice mid-infrared waveguide integrated detector.The GaAsSb waveguide layer and the InAs/GaAsSb superlattice absorbing layer are connected through evanescent coupling,facilitating efficient and highquality detection of mid-infrared light with minimal loss.We conducted a simulation to analyze the photoelectric characteristics of the device.Additionally,we investigated the factors that affect the integration of the InAs/GaAs⁃Sb superlattice photodetector and the GaAsSb waveguide.Optimal thicknesses and lengths for the absorption lay⁃er are determined.When the absorption layer has a thickness of 0.3μm and a length of 50μm,the noise equiva⁃lent power reaches its minimum value,and the quantum efficiency can achieve a value of 68.9%.The utilization of waveguide detectors constructed with Ⅲ-Ⅴ materials offers a more convenient means of integrating mid-infra⁃red light sources and achieving photoelectric detection chips. 展开更多
关键词 InAs/GaAsSb superlattice waveguide detector evanescent coupling GaAsSb waveguide
在线阅读 下载PDF
Effect of multiple coulomb scattering on the beam tests of silicon pixel detectors
14
作者 Lan-Kun Li Ming-Yi Dong +2 位作者 Ze Gao Liang-Cheng-Long Jin Shu-Jun Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期200-207,共8页
In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and perfo... In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and performance evaluation.When the beam energy is low,the effect of multiple Coulomb scattering on the measured resolution of the Device Under Test(DUT)must be considered to accurately evaluate the performance of the pixel chips and detectors.This study aimed to investigate the effect of multiple Coulomb scattering on the measured resolution,particularly at low beam energies.Simulations were conducted using Allpix^(2) to study the effects of multiple Coulomb scattering under different beam energies,material budgets,and telescope layouts.The simulations also provided the minimum energy at which the effect of multiple Coulomb scattering could be ignored.Compared with the results of a five-layer detector system tested with an electron beam at DESY,the simulation results were consistent with the beam test results,confirming the reliability of the simulations. 展开更多
关键词 Silicon Pixel detectors Beam Telescope Multiple Coulomb Scattering Spatial Resolution
在线阅读 下载PDF
10B-doped MCP detector developed for neutron resonance imaging at Back-n white neutron source
15
作者 Qiang Li Li‑Jiao Wang +70 位作者 Jing‑Yu Tang Xiang‑Biao Qiu Zhen Chen Mao‑Yuan Zhao Chang‑Jun Ning Kai Pan Wei Xu Tao Li Su‑Peng Lu Han Yi Rui‑Rui Fan Chang‑Qing Feng Rong Zhang Xiao‑Yang Sun Qi An Hao‑Fan Bai Jiang‑Bo Bai Jie Bao Ping Cao Qi‑Ping Chen Yong‑Hao Chen Zeng‑Qi Cui An‑Chuan Fan Fan‑Zhen Feng Min‑Hao Gu Chang‑Cai Han Zi‑Jie Han Guo‑Zhu He Yong‑Cheng He Yang Hong Yi‑Wei Hu Han‑Xiong Huang Wei Jiang Zhi‑Jie Jiang Zheng‑Yao Jin Ling Kang Bo Li Gong Li Xiao Li Yang Li Jie Liu Rong Liu Shu‑Bin Liu Yi‑Na Liu Guang‑Yuan Luan Jie Ren Zhi‑Zhou Ren Xi‑Chao Ruan Zhao‑Hui Song Kang Sun Zhi‑Xin Tan Sheng‑Da Tang Jin‑Cheng Wang Peng‑Cheng Wang Zhao‑Hui Wang Zhong‑Wei Wen Xiao‑Guang Wu Xuan Wu Cong Xia Yong‑Ji Yu Guo‑Hui Zhang Hang‑Chang Zhang Lin‑Hao Zhang Qi‑Wei Zhang Xian‑Peng Zhang Yu‑Liang Zhang Yue Zhang Zhi‑Yong Zhang Zhi‑Hao Zhou Ke‑Jun Zhu Chong Zou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期58-68,共11页
Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron s... Neutron resonance imaging(NRI)has recently emerged as an appealing technique for neutron radiography.Its complexity surpasses that of conventional transmission imaging,as it requires a high demand for both a neutron source and detector.Consequently,the progression of NRI technology has been sluggish since its inception in the 1980s,particularly considering the limited studies analyzing the neutron energy range above keV.The white neutron source(Back-n)at the China Spallation Neutron Source(CSNS)provides favorable beam conditions for the development of the NRI technique over a wide neutron energy range from eV to MeV.Neutron-sensitive microchannel plates(MCP)have emerged as a cutting-edge tool in the field of neutron detection owing to their high temporal and spatial resolutions,high detection efficiency,and low noise.In this study,we report the development of a 10B-doped MCP detector,along with its associated electronics,data processing system,and NRI experiments at the Back-n.Individual heavy elements such as gold,silver,tungsten,and indium can be easily identified in the transmission images by their characteristic resonance peaks in the 1–100 eV energy range;the more difficult medium-weight elements such as iron,copper,and aluminum with resonance peaks in the 1–100 keV energy range can also be identified.In particular,results in the neutron energy range of dozens of keV(Aluminum)are reported here for the first time. 展开更多
关键词 Neutron resonance imaging 10B doped MCP detector White neutron source Sample nuclide identification
在线阅读 下载PDF
宽谱红外/太赫兹量子棘轮探测器研究进展(内封面文章·特邀)
16
作者 楚卫东 白鹏 +4 位作者 杨宁 王屹 韩尚杰 王迎新 赵自然 《红外与激光工程》 北大核心 2025年第1期12-25,共14页
近年来,红外/太赫兹探测技术取得了卓越的进步,聚焦于当前主流的红外及太赫兹探测器就其优点和缺点进行相应评述。为满足现在科技水平所需的高速探测光子型红外/太赫兹探测器取得了广泛地关注和研究,但其工作温度低、响应光谱范围窄等... 近年来,红外/太赫兹探测技术取得了卓越的进步,聚焦于当前主流的红外及太赫兹探测器就其优点和缺点进行相应评述。为满足现在科技水平所需的高速探测光子型红外/太赫兹探测器取得了广泛地关注和研究,但其工作温度低、响应光谱范围窄等缺点限制了其应用的场景。就工作原理、工作模式、研究进展、能带工程等方面介绍GaAs基经典红外/太赫兹光子型探测器并进行评述。在此基础上,详细介绍文中提出的量子棘轮红外探测器(QRIP)的研究进展,从QRIP器件的工作原理、器件结构等方面阐述了其优势及可行性。通过研究QRIP不同的杂质类型、掺杂浓度、生长工艺、能带结构等条件以研究其工作机理及量子特性,列出了不同结构QRIP器件实验结果并进行了分析。棘轮结构在无外加电场下能够对红外能量进行探测,同时在特定的偏压下能够实现光谱可调的性质以实现宽谱的探测。进一步地,将QRIP集成LED制备出量子棘轮上转换器件,其能够实现4~200 THz的超宽谱探测,同时量子棘轮上转换探测器在25 K时响应率可以达到0.4 A/W。该研究表明了量子棘轮探测器能够有效提升器件的工作温度、响应光谱范围,为高工作温度红外/太赫兹光子型探测器实现提供了新思路。 展开更多
关键词 红外/太赫兹探测器 宽谱探测器 高温太赫兹探测 量子棘轮
在线阅读 下载PDF
干法后处理管道沉积源项小型中子探测技术研究
17
作者 郭庐阵 汪传高 +3 位作者 王莹 郭金森 庞洪超 骆志平 《原子能科学技术》 北大核心 2025年第S1期210-216,共7页
为测量一体化快堆核能系统熔盐电解干法后处理管道及工艺设备等部位沉积放射性物质的情况,以准确评估放射性物质实时沉积量及其辐射强度,确保人员和工艺安全,根据干法后处理工艺中子能谱、密封箱室结构和工艺设备参数等信息,研发了专用... 为测量一体化快堆核能系统熔盐电解干法后处理管道及工艺设备等部位沉积放射性物质的情况,以准确评估放射性物质实时沉积量及其辐射强度,确保人员和工艺安全,根据干法后处理工艺中子能谱、密封箱室结构和工艺设备参数等信息,研发了专用小型中子探测系统,对探测器计量性能(校准因子、相对固有误差、重复性)、防尘防水等级和电磁兼容性能进行了测试。测试结果显示其对252Cf中子源剂量率测量校准因子为1.07,对252Cf中子源剂量率测量相对固有误差为−6.5%,测量数据重复性为0.1%。探测器防尘防水等级为IP68,通过核仪器电磁环境条件与试验方法规定的电磁兼容测试。 展开更多
关键词 干法后处理 熔盐电解 沉积源项 中子探测器
在线阅读 下载PDF
CMOS低噪声高响应度太赫兹探测器线阵电路设计
18
作者 徐雷钧 马宇杰 +2 位作者 黄磊 白雪 陈建锋 《半导体技术》 北大核心 2025年第3期296-303,共8页
为了进一步提高电压响应度和探测成像速度,降低噪声等效功率,基于0.18μm CMOS工艺设计了一种低噪声高响应度太赫兹探测器线阵电路,提出了一种由自混频功率探测电路、电压缓冲级、运算放大器组成的1×4太赫兹阵列结构。通过源极差... 为了进一步提高电压响应度和探测成像速度,降低噪声等效功率,基于0.18μm CMOS工艺设计了一种低噪声高响应度太赫兹探测器线阵电路,提出了一种由自混频功率探测电路、电压缓冲级、运算放大器组成的1×4太赫兹阵列结构。通过源极差分驱动的自混频功率探测电路将辐射信号耦合至场效应管的栅极和源极,实现高响应度。通过电压缓冲级降低总体噪声,通过运算放大器有效放大探测信号。探测器线阵电路面积为0.8 mm^(2)。测试结果表明,当偏置电压为0.5 V时,该探测系统对0.37 THz辐射信号的电压响应度最大可达441 kV/W,对应的最小噪声等效功率为48 pW/Hz^(1/2)。相比单像素探测器,该探测器阵列可有效提升探测成像速度;相比传统的探测器阵列,该探测器阵列具有更优的性能参数。 展开更多
关键词 互补金属氧化物半导体(CMOS) 太赫兹 探测器 高响应度 低噪声
在线阅读 下载PDF
小型无人机视觉传感器避障方法综述
19
作者 王家亮 董楷 +2 位作者 顾兆军 陈辉 韩强 《西安电子科技大学学报》 北大核心 2025年第1期60-79,共20页
无人机自主飞行避障技术是无人机安全飞行和应用中最为基础和关键的技术,也是当前无人机领域的研究热点。随着深度学习在计算机视觉方向的应用,以及事件相机等视觉传感器技术的迅速发展与不断完善,基于视觉传感器的无人机自主飞行避障... 无人机自主飞行避障技术是无人机安全飞行和应用中最为基础和关键的技术,也是当前无人机领域的研究热点。随着深度学习在计算机视觉方向的应用,以及事件相机等视觉传感器技术的迅速发展与不断完善,基于视觉传感器的无人机自主飞行避障方法取得一定的进步,但目前有些研究方法在复杂场景下仍存在很大的挑战以及存在一些列亟待解决的问题,在精准性、实时性以及算法鲁棒性方面仍有改进空间。首先介绍无人机避障的相关概念及问题难点;然后将基于视觉传感器的避障算法根据采用的硬件及技术手段,具体划分为传统避障方法、基于深度学习避障方法、基于处理事件流的避障方法、基于传感器融合避障方法,和基于视觉避障的决策层避障方法,并分别介绍每类避障方法相关研究进展与研究成果,以及分析各类避障方法的优缺点;最后总结现有无人机避障算法存在的问题,并对未来研究工作进行展望。 展开更多
关键词 无人机 避障传感器 计算机视觉 事件相机
在线阅读 下载PDF
闪烁探测器全硬件自动检测控制电路设计
20
作者 李波 李晏敏 +7 位作者 赵娟 李洪涛 马烈华 艾杰 王城 张波涛 彭旭升 李涛 《强激光与粒子束》 北大核心 2025年第3期71-75,共5页
为满足中子测试装置对闪烁探测器的高可靠度要求,研制了一种全硬件自动检测控制电路。提出采用多谐振荡器产生设定时间周期的自检脉冲信号,利用比较器、单稳态触发器等电路对闪烁探测器主通道工作状态进行实时监测和判断,在主通道故障... 为满足中子测试装置对闪烁探测器的高可靠度要求,研制了一种全硬件自动检测控制电路。提出采用多谐振荡器产生设定时间周期的自检脉冲信号,利用比较器、单稳态触发器等电路对闪烁探测器主通道工作状态进行实时监测和判断,在主通道故障时通过模拟开关实现主通道信号和备用通道信号之间进行自动切换控制。解决了目前自动检测控制电路实现通道切换输出电路复杂、体积大、辐射环境适应性较差等问题,实现了闪烁探测器通道的冗余设计,提高了闪烁探测器的工作可靠度。该电路成功使探测器工作可靠度达到99.9%以上,满足了实验要求。 展开更多
关键词 闪烁探测器 全硬件电路 自动检测控制电路 高可靠度
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部