The problem of robust exponential stability for a class of switched nonlineardynamical systems with uncertainties and unbounded delay is addressed. On the assump-tion that the interconnected functions of the studied s...The problem of robust exponential stability for a class of switched nonlineardynamical systems with uncertainties and unbounded delay is addressed. On the assump-tion that the interconnected functions of the studied systems satisfy the Lipschitz condition,by resorting to vector Lyapunov approach and M-matrix theory, the sufficient conditions toensure the robust exponential stability of the switched interconnected systems under arbi-trary switching are obtained. The proposed method, which neither require the individualsubsystems to share a Common Lyapunov Function (CLF), nor need to involve the values ofindividual Lyapunov functions at each switching time, provide a new way of thinking to studythe stability of arbitrary switching. In addition, the proposed criteria are explicit, and it isconvenient for practical applications. Finally, two numerical examples are given to illustratethe correctness and effectiveness of the proposed theories.展开更多
Security and stability control system(SSCS)in power systems involves collecting information and sending the decision from/to control stations at different layers;the tree structure of the SSCS requires more levels.Fai...Security and stability control system(SSCS)in power systems involves collecting information and sending the decision from/to control stations at different layers;the tree structure of the SSCS requires more levels.Failure of a station or channel can cause all the execution stations(EXs)to be out of control.The randomness of the controllable capacity of the EXs increases the difficulty of the reliability evaluation of the SSCS.In this study,the loop designed SSCS and reliability analysis are examined for the interconnected systems.The uncertainty analysis of the controllable capacity based on the evidence theory for the SSCS is proposed.The bidirectional and loop channels are introduced to reduce the layers and stations of the existing SSCS with tree configuration.The reliability evaluation and sensitivity analysis are proposed to quantify the controllability and vulnerable components for the SSCS in different configurations.By aiming at the randomness of the controllable capacity of the EXs,the uncertainty analysis of the controllable capacity of the SSCS based on the evidence theory is proposed to quantify the probability of the SSCS for balancing the active power deficiency of the grid.展开更多
In an integrated refining and petrochemical complex,a centralized utility system(CUS)is introduced to integrate the steam demands of production plants.Besides,two sub-utility systems(SUSs)located inside the alkene and...In an integrated refining and petrochemical complex,a centralized utility system(CUS)is introduced to integrate the steam demands of production plants.Besides,two sub-utility systems(SUSs)located inside the alkene and refinery plants,respectively,can satisfy the shaft demands.It is difficult to determine the steam production of the CUS because the steam demands of the alkene and refinery plants also depend on the design and operation of the SUSs.To explore the complicated interaction between the CUS and SUSs,we proposed a mixed-integer nonlinear programming(MINLP)model for the design and optimization of multiple interconnected utility systems to minimize the total annualized cost(TAC).An extended superstructure was suggested to contain multiple inter-plant connected steam pipe alternatives between the CUS and SUSs.A more accurate model of the complex steam turbine was proposed.Then the proposed MINLP framework is applied to a new integrated refining and petrochemical complex.Two scenarios are investigated in the case study to explore the effect of steam main temperatures on system configurations and operating parameters.By optimizing the main temperatures,a TAC of$2.7 million can be saved.Judging from the results of the two scenarios,the feasibility and effectiveness of the proposed framework for the design and optimization of multiple interconnected utility systems have been demonstrated.展开更多
基金supported by the Natural Science Foundation of China(11572264)the Foundation for Distinguished Young Talents in Higher Education of Guangdong(2016KQNCX103)
文摘The problem of robust exponential stability for a class of switched nonlineardynamical systems with uncertainties and unbounded delay is addressed. On the assump-tion that the interconnected functions of the studied systems satisfy the Lipschitz condition,by resorting to vector Lyapunov approach and M-matrix theory, the sufficient conditions toensure the robust exponential stability of the switched interconnected systems under arbi-trary switching are obtained. The proposed method, which neither require the individualsubsystems to share a Common Lyapunov Function (CLF), nor need to involve the values ofindividual Lyapunov functions at each switching time, provide a new way of thinking to studythe stability of arbitrary switching. In addition, the proposed criteria are explicit, and it isconvenient for practical applications. Finally, two numerical examples are given to illustratethe correctness and effectiveness of the proposed theories.
基金supported by Science and Technology Project of SGCC“Research on Flat Architecture and Implementation Technology of Security and Stability Control System in Ultra Large Power Grid”(52170221000U).
文摘Security and stability control system(SSCS)in power systems involves collecting information and sending the decision from/to control stations at different layers;the tree structure of the SSCS requires more levels.Failure of a station or channel can cause all the execution stations(EXs)to be out of control.The randomness of the controllable capacity of the EXs increases the difficulty of the reliability evaluation of the SSCS.In this study,the loop designed SSCS and reliability analysis are examined for the interconnected systems.The uncertainty analysis of the controllable capacity based on the evidence theory for the SSCS is proposed.The bidirectional and loop channels are introduced to reduce the layers and stations of the existing SSCS with tree configuration.The reliability evaluation and sensitivity analysis are proposed to quantify the controllability and vulnerable components for the SSCS in different configurations.By aiming at the randomness of the controllable capacity of the EXs,the uncertainty analysis of the controllable capacity of the SSCS based on the evidence theory is proposed to quantify the probability of the SSCS for balancing the active power deficiency of the grid.
文摘In an integrated refining and petrochemical complex,a centralized utility system(CUS)is introduced to integrate the steam demands of production plants.Besides,two sub-utility systems(SUSs)located inside the alkene and refinery plants,respectively,can satisfy the shaft demands.It is difficult to determine the steam production of the CUS because the steam demands of the alkene and refinery plants also depend on the design and operation of the SUSs.To explore the complicated interaction between the CUS and SUSs,we proposed a mixed-integer nonlinear programming(MINLP)model for the design and optimization of multiple interconnected utility systems to minimize the total annualized cost(TAC).An extended superstructure was suggested to contain multiple inter-plant connected steam pipe alternatives between the CUS and SUSs.A more accurate model of the complex steam turbine was proposed.Then the proposed MINLP framework is applied to a new integrated refining and petrochemical complex.Two scenarios are investigated in the case study to explore the effect of steam main temperatures on system configurations and operating parameters.By optimizing the main temperatures,a TAC of$2.7 million can be saved.Judging from the results of the two scenarios,the feasibility and effectiveness of the proposed framework for the design and optimization of multiple interconnected utility systems have been demonstrated.