期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
美国《保健物理》(Health Physics)杂志英文摘要(2025年128卷第6期)
1
《辐射防护》 北大核心 2025年第5期539-544,共6页
Evaluation of Gamma Index Analysis for Detecting Errors in Patient-specific Quality Assurance in Intensity Modulated Radiotherapy Taylan Tugrul1(1.Department of Radiation Oncology,Medicine Faculty of Van Yüzü... Evaluation of Gamma Index Analysis for Detecting Errors in Patient-specific Quality Assurance in Intensity Modulated Radiotherapy Taylan Tugrul1(1.Department of Radiation Oncology,Medicine Faculty of Van YüzüncüYıl University,Van,Turkey)Abstract:Quality assurance practices performed before treatment are believed to identify various potential errors.In this study,2-dimensional(2D)dosimetric results were analyzed by making some intentional mistakes in six different treatment plans.In this way,the detectability of errors was investigated.In all segments of all treatment plans,one of the multileaf collimators was kept fixed at different positions on the central axis.In addition to multileaf collimators error,gantry error was also examined in the study.The dose distribution results obtained by Treatment Planning System(TPS)were compared with those obtained by the 2D array device,both as local calculation and global calculation methods,using the gamma analysis method.When the results are examined in the case where the Multi-leaf collimators(MLC)is fixed at the 1 cm position. 展开更多
关键词 making some intentional mistakes six different treatment plansin multileaf collimators patient specific quality assurance gantry error intensity modulated radiotherapy assurance practices gamma index analysis
在线阅读 下载PDF
Absorption Line Profile Recovery Based on TDLS and MEMS Micro-Mirror for Photoacoustic Gas Sensing
2
作者 LI Li Norhana Arsad +3 位作者 George Stewart Deepak Uttamchandani Brian Culshaw WANG Yi-ding 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2011年第7期1814-1818,共5页
A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirr... A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirror reflection.Tunable diode laser spectroscopy(TDLS) and photoacoustic spectroscopy(PAS) are used to recover the target absorption line profile which is compared with the theoretical Voigt profile.The target gas is 0.01% acetylene(C2H2) in a nitrogen host gas.The laser diode wavelength is swept across the P17 absorption line of acetylene at 1 535.4 nm by a current ramp,and an erbium-doped fibre amplifier(EDFA) is used to enhance the optical intensity and increase the signal-to-noise ratio(SNR).A SNR of about 35 is obtained with 100 mW laser power from the EDFA.Good agreement is achieved between the experimental results and the theoretical simulation for the P17 absorption line profile. 展开更多
关键词 Micro-electro-mechanical-systems(MEMS) Laser intensity modulation Absorption line profile recovery Tunable diode laser spectroscopy Photo-acoustic gas sensing
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部