Evaluation of Gamma Index Analysis for Detecting Errors in Patient-specific Quality Assurance in Intensity Modulated Radiotherapy Taylan Tugrul1(1.Department of Radiation Oncology,Medicine Faculty of Van Yüzü...Evaluation of Gamma Index Analysis for Detecting Errors in Patient-specific Quality Assurance in Intensity Modulated Radiotherapy Taylan Tugrul1(1.Department of Radiation Oncology,Medicine Faculty of Van YüzüncüYıl University,Van,Turkey)Abstract:Quality assurance practices performed before treatment are believed to identify various potential errors.In this study,2-dimensional(2D)dosimetric results were analyzed by making some intentional mistakes in six different treatment plans.In this way,the detectability of errors was investigated.In all segments of all treatment plans,one of the multileaf collimators was kept fixed at different positions on the central axis.In addition to multileaf collimators error,gantry error was also examined in the study.The dose distribution results obtained by Treatment Planning System(TPS)were compared with those obtained by the 2D array device,both as local calculation and global calculation methods,using the gamma analysis method.When the results are examined in the case where the Multi-leaf collimators(MLC)is fixed at the 1 cm position.展开更多
A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirr...A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirror reflection.Tunable diode laser spectroscopy(TDLS) and photoacoustic spectroscopy(PAS) are used to recover the target absorption line profile which is compared with the theoretical Voigt profile.The target gas is 0.01% acetylene(C2H2) in a nitrogen host gas.The laser diode wavelength is swept across the P17 absorption line of acetylene at 1 535.4 nm by a current ramp,and an erbium-doped fibre amplifier(EDFA) is used to enhance the optical intensity and increase the signal-to-noise ratio(SNR).A SNR of about 35 is obtained with 100 mW laser power from the EDFA.Good agreement is achieved between the experimental results and the theoretical simulation for the P17 absorption line profile.展开更多
文摘Evaluation of Gamma Index Analysis for Detecting Errors in Patient-specific Quality Assurance in Intensity Modulated Radiotherapy Taylan Tugrul1(1.Department of Radiation Oncology,Medicine Faculty of Van YüzüncüYıl University,Van,Turkey)Abstract:Quality assurance practices performed before treatment are believed to identify various potential errors.In this study,2-dimensional(2D)dosimetric results were analyzed by making some intentional mistakes in six different treatment plans.In this way,the detectability of errors was investigated.In all segments of all treatment plans,one of the multileaf collimators was kept fixed at different positions on the central axis.In addition to multileaf collimators error,gantry error was also examined in the study.The dose distribution results obtained by Treatment Planning System(TPS)were compared with those obtained by the 2D array device,both as local calculation and global calculation methods,using the gamma analysis method.When the results are examined in the case where the Multi-leaf collimators(MLC)is fixed at the 1 cm position.
基金Financial support from National High Technology Research and Development Programof China(Grant No.:2007A A06Z1122007AA03Z446)
文摘A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirror reflection.Tunable diode laser spectroscopy(TDLS) and photoacoustic spectroscopy(PAS) are used to recover the target absorption line profile which is compared with the theoretical Voigt profile.The target gas is 0.01% acetylene(C2H2) in a nitrogen host gas.The laser diode wavelength is swept across the P17 absorption line of acetylene at 1 535.4 nm by a current ramp,and an erbium-doped fibre amplifier(EDFA) is used to enhance the optical intensity and increase the signal-to-noise ratio(SNR).A SNR of about 35 is obtained with 100 mW laser power from the EDFA.Good agreement is achieved between the experimental results and the theoretical simulation for the P17 absorption line profile.