期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Room temperature gas sensor based on tube-like hydroxyapatite modified with gold nanoparticles 被引量:1
1
作者 罗兰兰 刘咏 +3 位作者 谭彦妮 李会霞 张青 李昆 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第1期18-26,共9页
The main goal of this work is to explore the possibility of using Au-modified hydroxyapatite(HA) as a potential sensor material. Tube-like HA structure was fabricated with the aid of a Nafion N-117 cation exchange mem... The main goal of this work is to explore the possibility of using Au-modified hydroxyapatite(HA) as a potential sensor material. Tube-like HA structure was fabricated with the aid of a Nafion N-117 cation exchange membrane and gold(Au) nanoparticles were added by a hydrothermal method. The morphology, structure and composition were characterized by scanning electron microscopy(SEM), transmission electron microscopy(TEM), X-ray diffraction(XRD), and X-ray photoelectron spectroscopy(XPS). The gas sensing properties were also investigated. Results show that Au nanoparticles are dispersed into the HA powder, which is tube-like, with rough inner and outer surfaces. Compared with pure HA, Au-modified HA exhibits improved sensing properties for NH_3. 5%(mass fraction) Au-modified HA shows the highest response with relatively short response/recovery time. The response is up to 79.2% when the corresponding sensor is exposed to 200×10^(-6) NH_3 at room temperature, and the response time and recovery time are 20 s and 25 s, respectively. For lower concentration, like 50×10^(-6), the response is still up to 70.8%. Good selectivity and repeatability are also observed. The sensing mechanism of high response and selectivity for NH_3 gas was also discussed. These results suggest that Au-HA composite is a promising material for NH_3 sensors operating at room temperature. 展开更多
关键词 gas sensor Au nanoparticles HYDROXYAPATITE gas selectivity ammonia gas
在线阅读 下载PDF
Room temperature hydrogen sensing performances of multiple networked Ga N nanowire sensors codecorated with Au and Pt nanoparticles 被引量:2
2
作者 PARK Sunghoon KIM Soohyun +2 位作者 PARK Suyoung LEE Sangmin LEE Chongmu 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1614-1618,共5页
The sensing performances of multiple networked Ga N nanowire(NW) sensor codecorated with Au and Pt nanoparticles were examined. The pristine Ga N nanowires show responses of approximately 108%-173% to 0.05%-0.25% H2 a... The sensing performances of multiple networked Ga N nanowire(NW) sensor codecorated with Au and Pt nanoparticles were examined. The pristine Ga N nanowires show responses of approximately 108%-173% to 0.05%-0.25% H2 at room temperature. On the other hand, the Ga N nanowires decorated with Au and those decorated with Pt lead to 1.1-1.3 and 1.2-1.6 times,respectively, stronger responses to 0.05%-0.25% H2. In contrast, the Au Pt-codecorated Ga N nanowires show 1.3-2.0 times stronger responses to 0.05%-0.25% H2. In other words, the Ga N nanorods codecorated with Au and Pt nanoparticles show much stronger response to H2 gas than the Au or Pt monometal-decorated counterpart. The underlying mechanism for the enhanced response of the Au Pt-codecorated Ga N nanowire was discussed. 展开更多
关键词 Ga N nanowires metal catalyst bimetallic system gas sensor codecoration
在线阅读 下载PDF
单壁碳纳米管气体传感器在GIS局部放电检测中的应用(英文) 被引量:2
3
作者 魏宁 丁卫东 +2 位作者 朱宜东 苏春强 末广纯也 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2700-2706,共7页
This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by ... This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge. 展开更多
关键词 single-walled carbon nanotubes(SWCNTs) gas sensors partial discharge(PD) detection gas insulated switchgear(GIS) tank SF6 decomposition gas PD parameters
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部